Product Overview

The ABB EL3010-IPA is an EasyLine EL3000 Series continuous gas analyzer equipped with an infrared photometer for monitoring isopropyl alcohol (IPA) concentration in an inert gas stream.

This model is specifically configured for continuous measurement of up to 30 vol.% IPA in inert gas. It is intended for process monitoring where stable, continuous concentration measurement is required rather than occasional laboratory sampling. ABB documentation also specifies that the EL3010-IPA is not intended for measurement of ignitable gas/air or gas/oxygen mixtures and should be installed in a non-hazardous environment.

The analyzer provides a built-in display and menu system for measurement, configuration, alarm settings, calibration and diagnostic functions. Its operator manual also documents Ethernet configuration and Modbus parameters for system integration.

Technical Specifications

Parameter Specification
Brand ABB
Model EL3010-IPA
Series EasyLine EL3000
Product Type Continuous Gas Analyzer
Analyzer Principle Infrared Photometer
Target Measurement IPA concentration
Measuring Range Up to 30 vol.% IPA in inert gas
Measurement Mode Continuous
Power Supply AC 100–240 V, 50/60 Hz
Rated Power 100 VA
Operating Environment Non-hazardous installation area
Environmental Temperature 5 to 50 °C, depending on installed certified module
Humidity Up to 75% RH, non-condensing
Pressure Sensor Installed as standard
Communication Ethernet / Modbus functions supported
Display Integrated analyzer display
Housing / Protection Configuration-dependent; verify type plate
Condition of Referenced eBay Unit Used

The AC 100–240 V, 50/60 Hz and 100 VA ratings are documented for the EL3010-IPA/IPA2 in ABB certification documentation. Exact enclosure and I/O configuration should be confirmed from the analyzer’s type plate before installation.

 

Key Features

  • Continuous IPA concentration measurement in inert gas
  • Infrared photometer measurement technology
  • Measuring capability up to 30 vol.% IPA
  • Integrated pressure sensor
  • Front-panel display and menu-based operation
  • Configurable measurement ranges and alarm values
  • Ethernet communication and Modbus functions
  • Built-in diagnostic and status functions
  • Designed for continuous industrial process monitoring
  • ABB EasyLine EL3000 platform

The EL3010-IPA operating documentation includes functions for range configuration, alarm values, low-pass time constants, I/O configuration, Ethernet configuration, Modbus parameters and analyzer diagnostics.

 

Typical Applications

The EL3010-IPA can be used where IPA concentration needs to be monitored continuously in an inert process-gas environment.

Typical applications include:

  • Semiconductor manufacturing processes
  • Solvent and IPA process monitoring
  • Industrial gas monitoring
  • Chemical processing
  • Process control and quality monitoring
  • Gas concentration monitoring around production equipment
  • Integration with plant DCS or SCADA systems

For semiconductor and process equipment applications, the analyzer can provide continuous concentration information to the plant control system rather than relying on periodic manual sampling.

 

Installation & Configuration

Before installation, verify the complete analyzer configuration from the type plate and analyzer data sheet. ABB documentation identifies the analyzer order number, part number, production number, manufacturing date, power supply and other configuration information on the analyzer data sheet.

Installation checklist

  1. Confirm the EL3010-IPA model and complete configuration code.
  2. Check the rated supply voltage before energizing the analyzer.
  3. Connect protective earth before other electrical connections.
  4. Connect the sample-gas inlet and outlet according to the pneumatic diagram.
  5. Check the pressure-sensor connection.
  6. Purge the sample-gas feed path before introducing the process gas.
  7. Allow the analyzer to complete its warm-up procedure.
  8. Configure the measurement range and alarm limits.
  9. Verify communication and analog I/O where applicable.
  10. Perform the required calibration before putting the analyzer into service.

ABB specifically requires the sample-gas path to be purged before commissioning. During warm-up, nitrogen purging may also be required where necessary to prevent condensation or dew-point problems inside the sample path.

 

Calibration and Maintenance

Regular calibration is important for maintaining reliable gas-concentration measurements.

Recommended maintenance checks include:

  • Inspect sample tubing and fittings for leaks.
  • Check filters and the sample-gas path for contamination or blockage.
  • Verify sample flow and pressure.
  • Check the pressure sensor connection.
  • Perform zero/span or applicable calibration according to the process requirement.
  • Review analyzer status and diagnostic messages.
  • Verify analog and communication outputs.
  • Keep the sample path clean and dry.
  • Record calibration results for process traceability.

The ABB manual includes dedicated procedures for calibration, test-gas concentration, I/O testing, diagnostics and analyzer status.

 

Inspection & Testing

For a used EL3010-IPA, the following checks are recommended before shipment or installation:

Visual Inspection

  • Check the front display and keypad.
  • Inspect the housing for dents, corrosion or mechanical damage.
  • Check gas fittings and ports.
  • Inspect electrical connectors.
  • Verify the ABB model and serial-number labels.

Power-On Test

  • Confirm normal startup.
  • Check display operation.
  • Record software/firmware information where available.
  • Verify that no persistent fault or maintenance alarm is present.

Functional Test

  • Confirm analyzer measurement response.
  • Check applicable analog outputs.
  • Test Ethernet/Modbus communication when the required test equipment is available.
  • Verify calibration functions.
  • Check sample-gas flow and pressure monitoring.

The exact test procedure should follow the installed configuration and ABB operating documentation.

 

Important Safety Note

The EL3010-IPA is specifically documented for measurement of IPA in inert gas and is not intended for ignitable gas/air or gas/oxygen mixtures. The installation must also satisfy the applicable electrical and gas-handling safety requirements.

Do not assume that every EL3010-IPA has the same I/O, enclosure protection or internal configuration. ABB’s certification documentation shows that different configuration codes can specify different enclosure and connection options.

 

Frequently Asked Questions

What does the EL3010-IPA measure?

It is configured for continuous measurement of IPA concentration in an inert gas stream, with a measurement capability of up to 30 vol.% IPA.

What measurement principle does it use?

The EL3010-IPA uses an infrared photometer for the IPA measurement.

What is the power supply?

The documented EL3010-IPA/IPA2 configuration is rated for AC 100–240 V, 50/60 Hz, 100 VA.

Can it be connected to a control system?

Yes. The EL3000 platform provides configurable I/O and Ethernet/Modbus functions. The exact available interfaces depend on the installed configuration.

Is this model suitable for measuring IPA in air?

No. The ABB manual specifically states that this analyzer is designed for IPA in inert gas and must not be used for ignitable gas/air or gas/oxygen mixtures.

Is EL3010-IPA the same as EL3020 or EL3040?

No. They belong to the same EL3000 family but use different analyzer configurations and measurement technologies. EL3010-IPA is a specific IPA infrared-photometer configuration.

 

Related ABB Models

The following models belong to the same or closely related ABB continuous gas-analyzer family:

  • ABB EL3010-C
  • ABB EL3020
  • ABB EL3040
  • ABB EL3060
  • ABB Uras26
  • ABB Magnos206
  • ABB Limas23
  • ABB Fidas24
  • ABB AO2000
  • ABB Advance Optima

These are related products within ABB’s analytical product range and should not be treated as direct drop-in replacements without checking the measurement principle, gas configuration, electrical connections and application requirements. ABB currently provides EL3000 documentation covering the EasyLine continuous gas analyzer family.

 

Identification & Ordering Notes

When purchasing or replacing an EL3010-IPA, it is useful to provide:

  • Full model number
  • Complete type-code / configuration code
  • Serial number
  • Analyzer data-sheet information
  • Installed software version
  • Supply-voltage configuration
  • Enclosure/protection option
  • Required gas measurement range
  • Available communication and I/O interfaces

For an existing installation, matching the complete configuration is much safer than selecting a unit based only on the EL3010-IPA model name.

Suggested eBay SEO Title:
ABB EL3010-IPA | EL3000 Series Continuous IPA Gas Analyzer Infrared Photometer

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.