Description
⚙️ Product Overview
The UNS3020 is an ABB UNITROL ground fault protection relay used with excitation systems to monitor and protect against ground faults associated with generator rotor circuits. ABB service documentation specifically identifies the UNS3020 as a ground fault relay used in UNITROL excitation-system maintenance and functional testing.
Part number HIEE205010R0001 is commonly identified with the configuration UNS3020A-Z V1. The unit is intended for system-specific installation within compatible ABB UNITROL excitation equipment and should be matched by part number, version, wiring, and existing system configuration before replacement.

🔧 Key Features
- ABB UNITROL excitation-system protection component
- Model UNS3020
- Part number HIEE205010R0001
- Configuration commonly identified as UNS3020A-Z V1
- Ground fault / earth fault protection function
- Designed for excitation-system applications
- Used for monitoring ground-fault conditions in generator excitation systems
- Front-panel indication and adjustment functions on applicable versions
- Suitable for maintenance, refurbishment, and replacement applications
- Useful as a critical spare for legacy UNITROL installations
📊 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | ABB |
| Model | UNS3020 |
| Part Number | HIEE205010R0001 |
| Version | UNS3020A-Z V1 |
| Product Name | UNITROL Ground Fault Relay |
| Series | ABB UNITROL Excitation System |
| Function | Ground / Earth Fault Protection |
| Application | Generator Excitation System |
| Condition / Status | Used; verify actual unit condition and revision |
| Weight | Approx. 1–6 kg depending on packaging/configuration; verify actual unit |
🏭 Typical Applications
The UNS3020 is intended for protection and maintenance of excitation systems used in:
- Turbo-generator excitation systems
- Hydro-generator excitation systems
- Synchronous generator systems
- Industrial power-generation plants
- Static excitation systems
- Automatic voltage regulator systems
- UNITROL excitation cabinets
- Generator rotor insulation monitoring and protection applications
🔌 Protection Function
The UNS3020 is associated with ground-fault protection within ABB UNITROL excitation systems. Its role is to detect abnormal ground-fault conditions and provide the corresponding protection indication or trip-related signal according to the installed excitation-system configuration.
For generator maintenance, the relay forms part of the protection functions that should be checked during an excitation-system service. ABB service documentation includes checking the UNS3020 or equivalent ground-fault relay as part of UNITROL performance review procedures.
Because UNITROL systems can be configured differently according to generator, excitation equipment, and project requirements, the exact trip thresholds, sensing arrangement, output contacts, and auxiliary supply should be verified from the installed relay and system documentation.
🛠️ Installation & Maintenance
First-Operation Checklist
- Confirm the relay marking HIEE205010R0001.
- Check the UNS3020A-Z V1 configuration and revision.
- Compare terminal arrangement with the existing relay.
- Isolate the excitation system before removing the existing unit.
- Inspect terminals and wiring for corrosion or overheating.
- Install the relay in the correct position.
- Verify sensing and auxiliary connections.
- Check relay indication and adjustment settings.
- Perform the applicable ground-fault protection test.
- Confirm correct alarm/trip behavior before returning the excitation system to service.
Maintenance Recommendations
- Inspect the relay during scheduled excitation-system maintenance.
- Check terminals for looseness, oxidation, or overheating.
- Verify ground-fault detection using the approved test procedure.
- Record the installed relay version and settings.
- Compare replacement-unit markings before installation.
- Keep a tested spare available for critical generator installations.
- Do not change protection settings without following the approved generator/excitation protection procedure.
❓ Common Questions & Answers
Q1: What is ABB UNS3020?
A: It is a UNITROL ground fault protection relay used in compatible ABB excitation systems.
Q2: What is the part number?
A: The commonly identified part number is HIEE205010R0001.
Q3: What is UNS3020A-Z V1?
A: It is a configuration/version designation associated with HIEE205010R0001.
Q4: What does the relay protect?
A: It is used for ground/earth fault protection associated with generator excitation systems, particularly rotor-side fault monitoring applications.
Q5: Is UNS3020 used in UNITROL systems?
A: Yes. ABB service documentation specifically references the UNS3020 ground fault relay as a component checked during UNITROL excitation-system service.
Q6: Can HIEE205010R0001 be used as a universal ground-fault relay?
A: No. It should be treated as a system-specific ABB UNITROL component and matched to the existing excitation-system configuration.
Q7: Should the relay be tested after replacement?
A: Yes. Ground-fault detection, alarm/trip signaling, sensing connections, and the associated excitation-system protection circuit should be functionally tested.
Q8: Is it suitable as a spare part?
A: Yes. It is particularly valuable as a maintenance spare for installations where an existing UNITROL excitation system depends on the UNS3020 relay.
⭐ Recommended ABB UNITROL Models
- ABB UNS3020 Ground Fault Relay
- ABB UNS3020A-Z V1 HIEE205010R0001
- ABB UNITROL P Excitation System Modules
- ABB UNITROL 5000 Excitation Controllers
- ABB UNITROL F Excitation System Components
- ABB UNITROL Power Converter Modules
- ABB UNITROL Automatic Voltage Regulator Modules
- ABB UNITROL Excitation Protection Modules
- ABB UNITROL Field Control Components
- ABB UNITROL Generator Protection Spare Parts
📦 Spare-Parts Recommendation
For generator plants using legacy ABB UNITROL excitation equipment, keeping a tested UNS3020 HIEE205010R0001 spare can shorten troubleshooting and repair time when a ground-fault protection relay fails.
Before ordering, compare the HIEE205010R0001 part number, UNS3020 configuration, revision, terminal arrangement, auxiliary supply, sensing circuit, and installed protection settings with the existing unit. This is especially important for generator excitation systems where incorrect protection configuration can affect commissioning and machine operation.