The Auto-Maskin DCU 205 is a robust, microprocessor-based engine control and monitoring unit designed for the reliable management of diesel engines in marine and industrial applications. It serves as an integrated solution for monitoring engine parameters, controlling startup/shutdown sequences, and providing comprehensive alarm management. Engineered to withstand the demanding conditions of engine rooms, the DCU 205 provides a high-visibility interface that allows operators to oversee critical data, ensuring the longevity and optimal performance of the power plant.
Technical Specifications
💡 Part Number: DCU 205
💡 Device Type: Engine Control and Monitoring Unit
💡 Display: Integrated graphical LCD with adjustable backlighting
💡 Inputs: Configurable analog inputs (pressure/temp) and binary digital inputs
💡 Communication: Modbus RTU (RS485) for integration with external systems
💡 Protection Rating: IP54 (front-mounted)
💡 Operating Temperature: -20 °C to +70 °C
💡 Power Supply: 12/24 Vdc (wide range)
💡 Mounting: Panel-mount (flush)
💡 Country of Origin: Norway

Key Functional Features
- Engine Control: Manages automated start/stop sequences and throttle control for prime movers.
- Alarm Monitoring: Continuously tracks engine vital signs (oil pressure, cooling temperature, RPM) and triggers alerts/shutdowns upon detecting out-of-range values.
- Local HMI: Features an intuitive display that provides immediate access to real-time engine data, reducing the need for separate analog gauges.
- System Integration: Supports serial communication, allowing for the data to be exported to higher-level Power Management Systems (PMS) or vessel monitoring systems.
- Durability: Built with vibration-resistant components and environmental sealing to ensure operational continuity in harsh maritime or industrial settings.
Recommended Integration Components
🛠️ Pickup Sensor: Magnetic sensor for precise engine speed/RPM monitoring.
🛠️ Pressure/Temperature Transducers: Industry-standard 4–20 mA sensors for analog input data.
🛠️ Interface Relay Module: Used for external actuator control (starter solenoid, fuel shut-off).
🛠️ Modbus Gateway: For converting RS485 engine data to Ethernet/TCP-IP.
🛠️ Control Power Filter: Protects unit circuitry from voltage spikes during cranking.
🛠️ Configuration Software: For custom parameter setting and event log retrieval.