Description
⚡ Product Overview
The CONVERTEAM GDS1173-6016 is a Power Interface Board associated with Converteam / GE Energy Power Conversion equipment. Available technical listings identify it as a PIB-E / PIBe2 board, with references including 20X4550C1L, 123034691, R-4001, and CP06105. It is also identified as a PIBe2 configuration without firing functionality.
The board is intended for use within industrial power-conversion and drive-control equipment, providing the interface between the control electronics and the associated power-conversion architecture. Exact functionality depends on the complete equipment configuration and installed board set.

🔧 Key Features
- Converteam industrial power-conversion interface board
- Model: GDS1173-6016
- PIB-E / PIBe2 family reference
- Associated with GE Energy Power Conversion / Converteam equipment
- Used as an interface within power-electronic control systems
- Legacy spare suitable for maintenance and repair programs
- Alternate identification references may appear on the board label
- Configuration should be verified before direct replacement
📊 Technical Datasheet
| Parameter | Specification |
|---|---|
| Brand | CONVERTEAM |
| Model | GDS1173-6016 |
| Product Series | Converteam / GE Power Conversion |
| Product Name | Power Interface Board |
| Product Type | Power Interface / Control PCB |
| Board Reference | PIB-E / PIBe2 |
| Related Reference | 20X4550C1L / 123034691 / R-4001 |
| Firing Function | Configuration identified as without firing |
| Application | Industrial Power Conversion and Drive Systems |
| Product Status | Legacy Industrial Automation Spare |
⚙️ Power Conversion System Function
The GDS1173-6016 belongs to the interface layer of a power-conversion control system. In a typical architecture, the board works with other control and power-electronic assemblies rather than operating as an independent controller.
Its position can generally be considered within the following system chain:
Control Electronics → Power Interface Board → Power Conversion Assembly → Motor / Industrial Load
The exact signal paths, firing-control architecture, feedback circuits, and connected modules must be confirmed against the equipment-specific documentation.
🔌 System Integration
When replacing a GDS1173-6016, identification of the complete board assembly is important. The following should be checked before installation:
- GDS1173-6016 part number
- PCB revision
- Connector arrangement
- Board markings and jumper configuration
- Associated power-conversion modules
- Control-board configuration
- Existing cable connections
- Equipment model and cabinet configuration
The reference PIBe2 may be particularly useful when comparing the replacement board against an installed assembly.
🛠️ Installation & Commissioning
1. Isolate the equipment
Disconnect and verify all relevant power sources before removing the existing PCB.
2. Record connections
Document connector positions and cable routing before removal.
3. Inspect the replacement
Check the PCB for damaged components, contamination, corrosion, loose connectors, or mechanical damage.
4. Verify configuration
Compare revision markings, jumpers, connectors, and board identifiers with the original unit.
5. Install carefully
Use appropriate ESD precautions and ensure the board is correctly seated in its mounting or backplane arrangement.
6. Functional commissioning
After energization, check control-system status, alarms, feedback signals, and power-conversion operation before placing the equipment under normal load.
🔍 Troubleshooting
Board not recognized:
Check connector seating, backplane contacts, board revision, and associated control electronics.
Power-conversion system alarm:
Inspect the complete control and power-conversion chain rather than replacing the interface board immediately.
Intermittent operation:
Check PCB connectors, solder joints, contamination, vibration-related mechanical issues, and cabinet environmental conditions.
Incorrect control response:
Verify associated control boards, signal wiring, feedback circuits, and the configuration of the power-conversion system.
Replacement does not operate correctly:
Compare the complete part number and revision with the removed board. A visually similar Converteam PCB is not necessarily a direct substitute.
🔩 Maintenance Recommendations
- Store spare PCBs in ESD-protective packaging.
- Keep boards dry and free from conductive contamination.
- Inspect connectors before installation.
- Record board revision and identification markings.
- Maintain a tested spare for critical drive or power-conversion equipment.
- Avoid unnecessary adjustment of board-level components.
- Compare the replacement against the original before energizing the system.
♻️ Replacement Considerations
The GDS1173-6016 is best treated as a legacy Converteam power-conversion spare. Cross-references such as 20X4550C1L, 123034691, and R-4001 can assist with identification, but should not by themselves be treated as proof of interchangeability.
For critical equipment, confirm the complete assembly configuration, board revision, connectors, and associated control hardware before replacement.
❓ Frequently Asked Questions
Q: What is the CONVERTEAM GDS1173-6016?
A: It is a Converteam Power Interface Board used within industrial power-conversion and drive-control equipment.
Q: Is GDS1173-6016 a complete drive?
A: No. It is a PCB-level interface assembly intended to operate as part of a larger power-conversion system.
Q: What other identification numbers may appear with this board?
A: References associated with this assembly include 20X4550C1L, 123034691, R-4001, CP06105, PIB-E, and PIBe2.
Q: Does this board contain firing circuitry?
A: Available identification describes the GDS1173-6016 configuration as PIBe2 without firing. The complete equipment configuration should still be verified before installation.
Q: Can any Converteam PIB board replace it?
A: No. Board revision, configuration, connectors, and the associated power-conversion system must be checked for compatibility.
📦 Recommended Related CONVERTEAM Models
- CONVERTEAM GDS1173-6010 Power Interface Board
- CONVERTEAM GDS1029-4001 IGBT Protection Card
- CONVERTEAM 20X4372/20CCOAT IGBT Gate Drive Card
- CONVERTEAM 20X4245B1SR Drive Power Control Card
- CONVERTEAM SKiiP 792 GB170-3DK0175 Power Module
- CONVERTEAM MAE 99-04 Serial Interface Unit
- CONVERTEAM GDS Power Conversion Control Board
- GE ENERGY POWER CONVERSION D20 Control Module
- CONVERTEAM Drive Control PCB Assembly
- CONVERTEAM Power Conversion Interface Module
✅ Product Summary
The CONVERTEAM GDS1173-6016 is a legacy Power Interface Board / PIBe2 assembly used in Converteam power-conversion equipment. With cross-references such as 20X4550C1L and 123034691, it is an important identification target when sourcing replacement boards for existing industrial drive and power-conversion systems.
For replacement projects, always match the complete board number, revision, configuration, connectors, and associated equipment before installation.