🔹 Product Overview
The FIREYE 70D41 is a solid-state burner management control chassis designed for Fireye D-Series burner control applications. Fireye documentation identifies the 70D41 as the 230 VAC version of the 70D40 chassis. The 60-1386-2 specified with this unit is the standard closed wiring base for surface mounting.

⚙️ Important Identification Note
Although marketplace listings may describe this item as a “Burner Control Amplifier Module,” the Fireye documentation distinguishes the components:
- 70D41 = 230 VAC D-Series burner control chassis
- 60-1386-2 = closed wiring base for surface mounting
- Flame amplifiers are separate plug-in components selected according to the required flame scanner.
This distinction is important when purchasing a replacement because the amplifier type must match the scanner and burner application.
📊 Technical Data
| Parameter | Value |
|---|---|
| Brand | FIREYE |
| Model | 70D41 |
| Associated Part No. | 60-1386-2 |
| Series | D-Series Burner Management Controls |
| Product Name | Burner Control Chassis / Wiring Base |
| Product Type | Solid-State Burner Management Control |
| Chassis Voltage | 230 VAC |
| Wiring Base | 60-1386-2, Closed Surface-Mount Type |
| Mounting | Surface Mount |
| Application | Burner Management / Flame Safeguard |
| Condition | Verify listing condition |
🔥 Burner Control Application
The Fireye D40/D41 burner management controls are designed as building blocks for automatic burner control systems. The system can incorporate flame detection, ignition, programmer functions, and auxiliary control devices according to the application.
For flame detection, Fireye specifies different amplifier modules for different scanner technologies. For example, UV, infrared autocheck, and flame-rectification amplifiers are selected according to the compatible flame scanner.
🔧 60-1386-2 Wiring Base
The 60-1386-2 is not the amplifier itself. Fireye identifies it as the standard/closed wiring base for surface mounting and specifies it for use with D-Series and FLAME-MONITOR equipment. The alternative 60-1466-2 is the open wiring base intended for cabinet mounting.
🛠️ Installation & Maintenance Notes
- Verify that the replacement chassis is specifically 70D41 for the required 230 VAC application.
- Confirm the wiring base is 60-1386-2 before installation.
- Check the installed flame amplifier separately; do not substitute an amplifier without verifying scanner compatibility.
- Inspect wiring terminals and connectors for corrosion, looseness, or heat damage.
- Confirm burner interlocks and safety circuits before commissioning.
- Perform a complete burner sequence and flame-failure test after replacement.
- Follow the applicable Fireye installation and combustion-safety procedures.
❓ FAQ
Q1: What is the Fireye 70D41?
The 70D41 is a Fireye D-Series burner management control chassis for 230 VAC operation.
Q2: Is 60-1386-2 the amplifier module?
No. Fireye identifies 60-1386-2 as a wiring base, specifically a closed surface-mount base.
Q3: What is the difference between 70D40 and 70D41?
The 70D40 is the 120 VAC chassis, while the 70D41 is the 230 VAC version.
Q4: Does the 70D41 include a flame amplifier?
The chassis and flame amplifier are separate components. The appropriate amplifier must be selected according to the flame scanner being used.
Q5: What scanners can be used with Fireye D-Series systems?
The applicable amplifier determines scanner compatibility. Fireye documentation lists UV, infrared autocheck, and flame-rectification amplifier options for different scanner types.
Q6: Is the 60-1386-2 still available?
Fireye’s current availability listing includes 60-1386-2 as a base assembly, while also listing 70D41 as a unit assembly.