Description
⚡ Product Overview
The GE POWER FILTERS S-1164-60 is a high leakage current filter designed for industrial electrical and power conversion applications. The unit is rated for 500 V and 50–60 Hz operation and is intended to reduce conducted electrical noise and unwanted high-frequency interference within compatible power systems.
The S-1164-60 can be used as part of an industrial power filtering arrangement where electrical noise suppression and controlled grounding are important. It is particularly suitable for equipment involving power converters, drives, industrial control cabinets, and other power-electronic systems.

🔧 Main Features
- ⚡ 500 V electrical rating
- 🔄 Designed for 50–60 Hz power systems
- 🛡️ High leakage current filter configuration
- 🔇 Helps reduce conducted electrical interference
- 🏭 Suitable for industrial power and automation equipment
- 🔌 Designed for integration into compatible electrical power circuits
- 🧰 Useful for replacement and maintenance applications
- 📋 Suitable for industrial spare-parts inventory management
- 🌍 Applicable to power conversion and control-system environments
📋 Product Datasheet
| Parameter | Specification |
|---|---|
| 🏷️ Brand | GE POWER FILTERS |
| 📌 Model | S-1164-60 |
| 📦 Series | S-1100 Series Filter |
| ⚙️ Product Name | High Leakage Current Filter |
| ⚡ Voltage Rating | 500 V |
| 🔄 Frequency | 50–60 Hz |
| 🔌 Filter Type | High Leakage Current Filter |
| 🏭 Application | Industrial Power / Electrical Noise Suppression |
| 📐 Dimensions | Verify from individual unit |
| ⚖️ Weight | Verify from individual unit |
🏭 Typical Applications
The S-1164-60 may be incorporated into industrial electrical systems where conducted noise and high-frequency interference need to be controlled.
Typical application environments include:
- Industrial control cabinets
- Motor-drive systems
- Power conversion equipment
- Industrial machinery
- Power distribution equipment
- Factory automation systems
- Electrical control panels
- Power-generation auxiliary equipment
The exact application should be determined by the electrical characteristics of the complete system rather than by the filter model alone.
🔌 Installation Considerations
Before installation, verify the 500 V rating, 50–60 Hz operating frequency, circuit configuration, current requirements, terminal arrangement, and grounding method.
Because this is a high-leakage-current filter, proper protective grounding is particularly important. The filter should be installed according to the equipment manufacturer’s electrical design and applicable local safety requirements.
Keep power input and filtered output wiring arranged according to the system design. Avoid unnecessary parallel routing between unfiltered and filtered conductors, as this can reduce the effectiveness of EMI suppression.
Do not energize the circuit until all electrical connections, protective earth connections, enclosure arrangements, and upstream protection have been checked.
🛠️ Maintenance & Troubleshooting
1. Excessive Electrical Noise
Check whether the filter is correctly connected and grounded. Inspect input and output wiring for incorrect routing or damaged insulation.
2. Unexpected Ground-Fault Trips
A high-leakage-current filter can contribute to the total leakage current of an installation. Check the complete system leakage-current level and confirm that the protective device is correctly selected for the application.
3. Filter Overheating
Inspect terminal connections, load conditions, ventilation, and surrounding equipment. Loose connections or operation outside the intended electrical conditions can increase heating.
4. Abnormal Noise After Replacement
Confirm that the replacement unit has the same model and electrical rating as the original. Also inspect cable routing and grounding because filter performance depends on the complete installation.
5. Pre-Commissioning Inspection
Before returning the equipment to service, verify terminal tightness, insulation condition, grounding continuity, enclosure condition, and the electrical rating of the connected circuit.
🧰 Replacement Checklist
When replacing an S-1164-60, check:
- Model number: S-1164-60
- Voltage rating: 500 V
- Frequency: 50–60 Hz
- Input/output terminal configuration
- Existing filter wiring
- Protective earth connection
- Connected load characteristics
- Installation dimensions and mounting method
- Leakage-current requirements
- Overall system compatibility
❓ Common Questions & Answers
Q1: What is the GE S-1164-60?
A: It is a GE Power Filters high leakage current filter designed for compatible industrial electrical and power-conversion applications.
Q2: What voltage is the S-1164-60 rated for?
A: The referenced model designation is specified for 500 V operation.
Q3: What frequency does it support?
A: The supplied product specification indicates 50–60 Hz.
Q4: What is the purpose of this filter?
A: Its primary function is electrical noise and interference suppression within a compatible power system, while its high-leakage-current configuration is intended for applications where this characteristic is required.
Q5: Can it be used as a direct replacement?
A: Only after confirming the complete electrical and mechanical configuration of the existing installation. Matching the model number alone is not sufficient for a safety-critical electrical replacement.
Q6: Does the filter require grounding?
A: Proper protective grounding is essential. The grounding arrangement should follow the electrical design and applicable safety requirements for the installation.
Q7: Are exact dimensions available from the model number?
A: Exact physical dimensions should be verified from the individual unit or its applicable documentation before installation.
Q8: Is this suitable for industrial automation equipment?
A: Yes, it can be considered for compatible industrial power, automation, drive, and electrical-control applications where its voltage, frequency, leakage-current, and connection requirements match the system.
🔟 Recommended GE Related Models
- GE POWER FILTERS S-1164-60
- GE POWER FILTERS S-1100 Series
- GE POWER FILTERS S-1120 Series
- GE POWER FILTERS S-1150 Series
- GE POWER FILTERS S-1180 Series
- GE EMI Suppression Filter Series
- GE Industrial Line Filter Series
- GE Power Conversion Filter Assemblies
- GE Industrial Power Quality Filter Series
- GE Drive and Power Electronics Filter Assemblies
📦 Spare-Parts Value
The GE POWER FILTERS S-1164-60 can be maintained as a strategic spare for industrial electrical systems using the same filter configuration. Keeping a correctly identified replacement in inventory can reduce troubleshooting and equipment-restoration time when an installed filter requires replacement.
Before installation, always compare the replacement unit with the original equipment and verify its electrical rating, terminal arrangement, grounding requirements, and physical mounting configuration.
Model: GE POWER FILTERS S-1164-60
Product: High Leakage Current Filter
Rating: 500 V / 50–60 Hz
Application: Industrial Power & Electrical Noise Suppression