GUTOR UNC1X-0P-00089 | SDC Interface Card | A071

Original price was: $10,000.00.Current price is: $1,457.00.

Product NO:UNC1X-0P-00089

Brand:GUTOR

Delivery time:  In stock

Product status:   Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

The GUTOR UNC1X-0P-00089 is a GUTOR PCA SDC interface/power-supply board identified in industrial parts catalogs as a PCA SDC I/F PSU, 220 VDC, EMC reinforced, A071 board. The same part number is also listed in GUTOR spare-parts catalogs as a board.

The A071 designation identifies its position/function within the applicable GUTOR UPS architecture. This is a system-specific PCB and should not be treated as a universal DC power supply or communication card.

The available technical listing gives the board weight as approximately 1.36 kg.

GUTOR PCA SDC Interface Card UNC1X-0P-00089  Received Date 2023 Image 1 of 4

📋 Product Datasheet

Parameter Specification
Brand GUTOR Electronics
Model UNC1X-0P-00089
Series GUTOR UPS / SDC
Product Name PCA SDC Interface / Power Supply Board
Board Position A071
Input Voltage 220 VDC
EMC Design EMC Reinforced
Product Type PCB Interface / PSU Assembly
Weight Approx. 1.36 kg
Application GUTOR UPS and Converter Systems

The 220 VDC specification, EMC-reinforced design, A071 designation, and approximately 1.36 kg weight are documented in current industrial parts references.

⚠️ Exact output voltage/current, dimensions, connector pinout, power rating, and detailed communication protocol are not sufficiently documented in the available references. These values should be verified from the actual PCB and the applicable GUTOR system documentation.

 

🔧 Operating Standards & How to Use

🔹 Verify UNC1X-0P-00089 before installation.

🔹 Confirm that the host GUTOR equipment uses the A071 board position.

🔹 Verify the required 220 VDC system voltage.

🔹 Compare connector locations with the original board.

🔹 Photograph all wiring before removing the existing PCB.

🔹 Use ESD protection during handling.

🔹 Inspect terminals and connectors for corrosion or damage.

🔹 Verify polarity before energizing.

🔹 Do not use the board as a generic 220 VDC power supply.

🔹 Complete a controlled functional test after installation.

 

▶️ Startup Sequence

  1. 🔍 Confirm the part number and A071 designation.
  2. 🧰 Inspect the PCB for physical damage.
  3. 🔌 Verify all connectors and cable positions.
  4. 🛡️ Check grounding and protective devices.
  5. ⚡ Verify the DC supply is within the applicable system specification.
  6. 🔋 Restore the GUTOR UPS control/DC power according to the equipment procedure.
  7. 💡 Check system status indicators.
  8. 🖥️ Check the UPS controller for alarms.
  9. 📊 Verify the functions associated with the SDC interface.
  10. 🧪 Perform a controlled UPS functional test.

 

⏹️ Shutdown Sequence

  1. Place the UPS into the approved maintenance or bypass state.
  2. Follow the normal UPS shutdown procedure.
  3. Isolate the relevant AC/DC sources.
  4. Apply lockout/tagout procedures where required.
  5. Verify the DC circuit is de-energized.
  6. Allow stored energy to discharge according to the equipment procedure.
  7. Disconnect the PCB cables.
  8. Remove the board using ESD precautions.
  9. Install the replacement PCB.
  10. Restore power and verify normal operation.

⚠️ A 220 VDC UPS circuit can present a serious electrical hazard. Stored energy may remain after the main supply has been disconnected.

 

📘 Product Usage Instructions

The UNC1X-0P-00089 is associated with the SDC interface/power-supply function of compatible GUTOR UPS equipment. Industrial documentation describes it as a PCA SDC I/F PSU, 220 VDC, EMC reinforced, A071.

A simplified system relationship is:

220 VDC System Supply → UNC1X-0P-00089 / A071 → GUTOR SDC / UPS Electronics

Before replacement, record the original board’s:

🔹 Part number

🔹 Board position

🔹 Connector locations

🔹 Cable assignments

🔹 PCB revision

🔹 Jumper or configuration settings, if fitted

After installation, verify the DC input and associated UPS control/interface functions before returning the system to normal operation.

 

🛠️ Installation & Maintenance

🔹 Keep the PCB clean and dry.

🔹 Store it in an ESD-safe package.

🔹 Avoid touching connector contacts.

🔹 Inspect capacitors and power components for overheating.

🔹 Check PCB traces for discoloration or damage.

🔹 Inspect connectors for oxidation.

🔹 Verify correct mounting and cable routing.

🔹 Check polarity before power-up.

🔹 Record the installed part number and revision.

🔹 Perform a functional test after replacement.

 

❓ Common Questions & Answers

Q: What is GUTOR UNC1X-0P-00089?
A: It is a GUTOR PCA SDC interface/power-supply board used in compatible UPS and converter systems.

Q: What is the input voltage?
A: The available technical reference specifies 220 VDC.

Q: What does A071 mean?
A: A071 is the system board position/designation associated with this GUTOR SDC interface/PSU assembly.

Q: Is it a communication card?
A: Its description includes SDC I/F, but available references specifically describe it as a PCA SDC interface/power-supply board. It should not automatically be equated with a standard RS232, RS485, or Ethernet communication card.

Q: Is it a standalone 220 VDC power supply?
A: No. It is a system-specific GUTOR PCB assembly.

Q: What is the approximate weight?
A: The available listing gives approximately 1.36 kg.

Q: Can another GUTOR PSU replace it?
A: Not automatically. Input voltage, output characteristics, connector configuration, board position, EMC design, and UPS compatibility must be matched.

Q: Can it be hot-swapped?
A: Do not assume hot-swapping is supported. Follow the specific GUTOR maintenance procedure and normally isolate power before PCB replacement.

Q: What should I check before purchasing?
A: Confirm UNC1X-0P-00089, A071, 220 VDC configuration, connector arrangement, PCB condition, and compatibility with the customer’s GUTOR UPS.

 

⭐ Recommended GUTOR Related Series & Models

  1. GUTOR UNC1X-0P-00089 — SDC Interface / PSU Board
  2. GUTOR 0P0530-A076 — Communication Interface
  3. GUTOR 0P0282 — 400 VDC PSU PCB
  4. GUTOR 0P0284 — DC Power Supply PCB
  5. GUTOR 0P0280 — Power Supply Unit
  6. GUTOR 0P0363 — Control Unit
  7. GUTOR 0P5617AA — XXW RS232 Interface
  8. GUTOR 0P6284AC — PCB Assembly
  9. GUTOR 0P9914 — Printed Circuit Board
  10. GUTOR SILCON Series — Industrial UPS Systems

These are related GUTOR UPS components and interfaces, not confirmed direct replacements for UNC1X-0P-00089. GUTOR parts catalogs separately identify boards such as UNC1X-0P-00089, 0P5617AA, 0P0284AC, and 0P9914

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.