Description
Product Specifications
| Attribute | Specification |
|---|---|
| Model Number | 054015 |
| Revision | Rev:A |
| Product Type | Control Processing / Interface Board |
| System Compatibility | Measurex 2000 / 2002 Series Systems |
| Platform | Industrial PC Architecture |
| Dimensions | 240 mm x 175 mm x 20 mm |
| Weight | 0.42 kg |
| Origin | USA |
| Operating Voltage | +5V, +12V DC |
Application Fields

The Measurex 054015 Rev:A is a legacy control board designed for high-precision industrial measurement and control systems. It is primarily utilized in:
- Pulp and Paper Industry: Scanning and controlling paper weight, moisture, and caliper.
- Plastic Film Extrusion: Monitoring thickness and material distribution across webs.
- Aluminum Rolling Mills: Gauge control and surface quality monitoring.
- Textile Manufacturing: Ensuring consistent coating and density in fabric production.
- Rubber Processing: Real-time calibration of calendered sheets.
Product Instructions
- Chassis Installation: Slide the board into the designated slot of the Measurex central processing cabinet. Ensure the edge connectors are aligned with the backplane before applying pressure.
- Jumper Configuration: The Rev:A board may contain jumpers for addressing and interrupt settings. Verify these against the original system configuration to avoid hardware conflicts within the industrial PC bus.
- Cooling: Legacy boards can generate significant heat. Ensure that the cabinet’s cooling fans are operational and that air filters are clean to prevent thermal drift in the measurement logic.
- Handling: Use a grounded anti-static wrist strap when handling the board. The 054015 contains sensitive integrated circuits that are susceptible to damage from electrostatic discharge.
Product Q&A
Q1: Is the 054015 Rev:A compatible with modern Honeywell systems? A1: Since Honeywell acquired Measurex, some components are supported through legacy migration paths (like the Experion platform), but the 054015 is specifically hardware-designed for the Measurex 2000/2002 series racks.
Q2: How can I identify a failure on this board? A2: Common signs include “System Timeout” errors on the operator station or a failure of the scanning head to communicate with the main controller. Check the board for leaking electrolytic capacitors, which is a frequent issue in legacy hardware of this age.
Q3: Can this board be used to control third-party sensors? A3: No, the 054015 is designed with proprietary interface logic intended specifically for Measurex high-speed scanning sensors and actuators.
Related Product Models
- MEASUREX 053040
- MEASUREX 053910
- MEASUREX 086110
- MEASUREX 087640
- MEASUREX 053820