Description
📌 Product Overview
The NI PXIe-1075 is an 18-slot PXI Express chassis designed for modular test, measurement, automation, and data acquisition systems. It provides a high-bandwidth PXI Express backplane for installing a system controller together with PXI Express, PXI, CompactPCI Express, and CompactPCI peripheral modules.
The chassis includes 8 hybrid peripheral slots, 8 PXI Express peripheral slots, 1 dedicated PXI Express system timing slot, and 1 system controller slot. NI specifies system bandwidth of up to 4 GB/s and dedicated bandwidth of up to 1 GB/s per PXI Express slot in a single direction.
The PXIe-1075 is a legacy/discontinued NI chassis, but it remains relevant for maintaining existing PXI-based automated test and measurement systems.

⚙️ Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | NI / National Instruments |
| Model | PXIe-1075 |
| Product Name | PXI Express Chassis |
| Series | PXI Express |
| Total Slots | 18 |
| System Controller Slots | 1 |
| PXI Express Peripheral Slots | 8 |
| Hybrid Peripheral Slots | 8 |
| PXI Express System Timing Slot | 1 |
| Maximum System Bandwidth | Up to 4 GB/s |
| Dedicated PXIe Slot Bandwidth | Up to 1 GB/s per slot, single direction |
| Backplane Type | PXI Express high-performance backplane |
| Module Compatibility | PXI Express, PXI, CompactPCI Express, CompactPCI |
| PXI Express Specification | PXI-5 compliant |
| Reference Clock | PXI_CLK10 and PXIe_CLK100 |
| Synchronization | PXIe synchronization and timing support |
| Cooling Method | Forced-air cooling |
| Cooling Capacity | Approx. 38 W per slot class |
| Power Supply Type | AC |
| AC Frequency | 50/60 Hz |
| Operating Temperature | 0 to 55°C |
| Storage Temperature | -40 to 71°C |
| Height | 177.1 mm |
| Width | 464.8 mm |
| Depth | 467.4 mm |
| Weight | Approx. 14.06 kg / 31 lb |
| Product Status | Legacy / No longer available from NI |
The official NI product information confirms the 18-slot architecture, 8 hybrid slots, 8 PXI Express slots, dedicated system timing capability, and up to 4 GB/s chassis bandwidth. The NI chassis documentation lists dimensions of 177.1 × 464.8 × 467.4 mm and a weight of approximately 14.06 kg.
🔧 Key Features
- 18-slot PXI Express chassis
- High-bandwidth PXI Express backplane
- 8 PXI Express peripheral slots
- 8 hybrid slots for broader module compatibility
- Dedicated PXI Express system timing slot
- Dedicated system controller slot
- Up to 4 GB/s system bandwidth
- Up to 1 GB/s dedicated bandwidth per PXI Express slot
- PXI-5 PXI Express hardware compatibility
- PXI and PXI Express module support
- CompactPCI and CompactPCI Express compatibility
- Integrated timing and synchronization architecture
- Forced-air module cooling
- Rack-mount installation capability
- AC-powered chassis design
The PXIe-1075 backplane architecture is designed to support mixed module systems, allowing compatible PXI Express, PXI, CompactPCI Express, and CompactPCI hardware to be installed in the same chassis where the slot and module requirements are met.
🧪 Typical Applications
The NI PXIe-1075 is suitable for modular systems requiring multiple synchronized instruments and measurement modules.
Typical applications include:
- Automated test systems
- Electronic production testing
- Data acquisition systems
- RF and communication testing
- Semiconductor testing
- Industrial measurement
- Hardware-in-the-loop simulation
- Automated validation systems
- Aerospace and defense testing
- Laboratory instrumentation systems
- High-channel-count measurement platforms
The 18-slot design is particularly useful when multiple instruments, data acquisition modules, switching modules, timing devices, and controllers need to operate within one synchronized PXI platform.
🕒 Timing and Synchronization
PXI systems are widely used when multiple modules must operate with coordinated timing. The PXIe-1075 includes dedicated timing and synchronization resources through its PXI Express system timing architecture.
The chassis supports standard PXI and PXI Express timing resources, including a 10 MHz PXI reference clock and a 100 MHz PXI Express reference clock. This architecture helps synchronize compatible measurement and control modules installed within the chassis.
Before configuring a synchronized system, confirm the timing requirements of every installed module and verify which module is responsible for reference-clock or trigger generation.
🌬️ Cooling and Power
The PXIe-1075 uses forced-air cooling to support installed PXI modules. Cooling capacity and total chassis power requirements should be checked when multiple high-power modules are installed.
For system planning, consider:
- Total power consumption of all installed modules
- Cooling requirement of each module
- Controller power consumption
- Ambient operating temperature
- Airflow around the chassis
- Rack installation arrangement
- Empty-slot filler panels
NI chassis design guidance recommends considering both module power consumption and thermal requirements when configuring a PXI system.
🛠️ Installation Notes
Before installing modules into the PXIe-1075:
- Disconnect AC power.
- Inspect the backplane and slot connectors.
- Confirm the system controller is installed in the correct controller slot.
- Install PXI Express modules only in compatible slots.
- Check hybrid-slot compatibility before installing older PXI modules.
- Install timing-sensitive modules according to the system architecture.
- Use filler panels for unused slots where required.
- Confirm sufficient cooling clearance.
- Verify the total system power budget.
- Power up the chassis and check controller and module diagnostics.
Because the PXIe-1075 supports several module standards, physical compatibility alone does not guarantee complete system compatibility. The controller, module type, PCI Express link requirements, drivers, and application software should all be verified.
🔍 Inspection for Used or Surplus Equipment
For a used or surplus PXIe-1075 chassis, recommended inspection includes:
- Check the front and rear chassis panels.
- Inspect all 18 slot connectors.
- Check for bent backplane contacts.
- Inspect cooling fans for noise or abnormal operation.
- Test the AC power supply.
- Verify power and status indicators.
- Check the controller slot and timing slot.
- Inspect rack-mount points and chassis handles.
- Check for excessive dust or contamination.
- Perform a controlled power-up test.
If possible, test the chassis with a known compatible PXI controller and one or more verified PXI/PXIe modules.
❓ Frequently Asked Questions
Q: How many slots does the NI PXIe-1075 have?
A: The chassis has 18 total slots.
Q: How are the slots configured?
A: It includes 8 hybrid slots, 8 PXI Express peripheral slots, 1 PXI Express system timing slot, and 1 system controller slot.
Q: Can the PXIe-1075 use standard PXI modules?
A: Yes, compatible PXI modules can be used in the appropriate hybrid-slot configuration. The chassis architecture also supports compatible PXI Express, CompactPCI Express, and CompactPCI modules.
Q: What is the maximum system bandwidth?
A: NI specifies up to 4 GB/s system bandwidth for the PXIe-1075.
Q: What is the bandwidth available to a PXI Express slot?
A: The chassis documentation describes up to 1 GB/s of dedicated bandwidth per PXI Express slot in a single direction through an x4 PCI Express connection.
Q: What are the chassis dimensions?
A: The standard chassis dimensions are approximately 177.1 mm high × 464.8 mm wide × 467.4 mm deep.
Q: How much does the chassis weigh?
A: The chassis weight is approximately 14.06 kg, or 31 lb.
Q: Is the PXIe-1075 still available as a current NI product?
A: NI currently identifies the PXIe-1075 as no longer available, making it primarily a legacy platform for existing systems and replacement applications.
Q: Can any PXI controller be installed?
A: No. The controller must be compatible with the PXI Express system-controller slot and the chassis backplane architecture.
📦 Related NI PXI Models
The following NI PXI and PXI Express chassis models are related products and should not automatically be treated as direct replacements:
- NI PXIe-1071
- NI PXIe-1073
- NI PXIe-1081
- NI PXIe-1083
- NI PXIe-1084
- NI PXIe-1085
- NI PXIe-1086
- NI PXIe-1088
- NI PXIe-1092
- NI PXIe-1095
These chassis differ in slot count, PCI Express generation, bandwidth, cooling capacity, controller connectivity, and backplane architecture. Replacement selection should therefore be based on the installed modules and complete system requirements.
📌 Identification & Ordering Notes
When purchasing or replacing an NI PXIe-1075, verify:
- Complete model number: PXIe-1075
- Number and type of installed modules
- System controller compatibility
- Slot requirements
- Backplane condition
- Timing and synchronization requirements
- AC input configuration
- Cooling fan condition
- Power supply condition
- Rack installation requirements
For a used chassis, it is also important to confirm whether the sale includes only the chassis or includes a PXI controller, installed modules, filler panels, power cable, or other accessories.
Recommended Short Title
NI PXIe-1075 | 18-Slot PXI Express Chassis
This title keeps the strongest search terms: NI + PXIe-1075 + 18-Slot + PXI Express Chassis.