Description
🔹 Product Overview
The PHOENIX X-RAY BRV-03 + BAS-01 is a matched control-board assembly associated with Phoenix X-Ray inspection equipment. The combination is identified with reference IN9S1B1 and is intended for use within the control architecture of industrial X-ray inspection systems.
The BRV-03 and BAS-01 boards are shown together in Phoenix X-Ray system documentation and terminal-layout information, making the complete board combination particularly relevant when servicing an existing machine where the original board configuration must be maintained.
The available listing identifies the assembly as Used, removed from a working production line. Because these are system-specific control boards, the complete part marking, connector arrangement, revision, and machine configuration should be checked before installation.

⚙️ Key Features
- Brand: PHOENIX X-RAY
- Model: BRV-03 + BAS-01
- Reference: IN9S1B1
- Product Type: X-Ray system control board assembly
- Designed for integration into Phoenix X-Ray inspection equipment
- BRV-03 and BAS-01 supplied as a matched board combination
- Suitable for maintenance and replacement of legacy X-ray inspection systems
- Board-level replacement can help reduce machine downtime when an original control assembly becomes unavailable
- Connector and wiring configuration should be matched against the installed system before replacement
📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | PHOENIX X-RAY |
| Model | BRV-03 + BAS-01 |
| Reference | IN9S1B1 |
| Product Name | X-Ray System Control Boards |
| Product Type | Control Board Assembly |
| Application | Industrial X-Ray Inspection System |
| Associated System | Phoenix X-Ray inspection equipment |
| Condition | Used |
| Country of Origin | United States, according to the referenced listing |
| Dimensions | Configuration dependent; verify from the existing board |
| Weight | Not reliably specified |
| Power Requirement | System/configuration dependent; verify before installation |
🏭 X-Ray Inspection System Integration
The BRV-03 and BAS-01 combination should be treated as part of a larger machine-control architecture rather than as a standalone general-purpose controller.
Phoenix X-Ray system documentation identifies BRV-03 and BAS-01 within the service-driver/terminal layout of an X-ray inspection system. This indicates that the boards are installed as part of the machine’s internal electrical and control infrastructure.
During replacement, technicians should compare:
- Board identification and revision markings
- Connector positions and keying
- Cable labels
- Terminal assignments
- Board-to-board wiring
- Machine configuration
- Associated sensors and actuators
- Existing control-system software or parameter settings
Matching the complete assembly is especially important for legacy inspection equipment where several visually similar circuit boards may exist.
🔧 Control & Interface Considerations
The BRV-03 + BAS-01 assembly should be installed using the same electrical architecture as the original equipment.
Before powering the machine, verify:
- The BRV-03 identification matches the removed board.
- The BAS-01 identification matches the original assembly.
- All connector positions are correct.
- Cable orientation and terminal numbers are recorded.
- Grounding and shielding connections are restored.
- No bent, oxidized, or damaged connector pins are present.
- The board is securely mounted and mechanically supported.
- Any machine-specific configuration or calibration data is preserved.
Do not assume that another Phoenix X-Ray board with a similar designation is directly interchangeable without checking the complete machine configuration.
🧪 Typical Applications
The board assembly can be considered for maintenance of industrial X-ray inspection equipment used for applications such as:
- Industrial X-ray inspection
- Non-destructive testing systems
- Automated inspection machinery
- Production-line X-ray inspection
- Legacy Phoenix X-Ray equipment
- Machine-control and service electronics
- Replacement of failed or obsolete control boards
🛠️ Installation & Maintenance
Because the assembly is associated with X-ray inspection equipment, installation should be performed by qualified service personnel familiar with the machine’s electrical and radiation-safety procedures.
Recommended replacement procedure
1. Record the original configuration
Photograph connector locations, cable routing, board labels, and terminal numbers before removing the original assembly.
2. Isolate the equipment
Follow the machine manufacturer’s shutdown procedure and disconnect all required electrical power sources.
3. Verify the replacement boards
Confirm BRV-03, BAS-01, reference IN9S1B1, revision markings, and connector layout.
4. Inspect the boards
Check for cracked solder joints, corrosion, damaged connectors, contamination, or physical impact damage.
5. Install the assembly
Use the original mounting points and reconnect each cable according to the recorded configuration.
6. Perform controlled startup
Restore power according to the equipment service procedure and check for abnormal alarms or status indications.
7. Verify system operation
Confirm communication, machine interlocks, X-ray control functions, inspection sequence, and associated machine signals.
🔍 Troubleshooting Guide
Machine does not start after board replacement
Check board seating, connector engagement, supply rails, grounding, and interlock circuits. Confirm that no cable has been connected to an adjacent or similar connector.
Control signals are missing
Inspect terminal wiring and board-to-board connections. A loose connector or incorrect cable position can interrupt machine control signals.
System reports an unexpected board or configuration fault
Compare the replacement board’s markings and revision with the original. Some legacy systems may require a specific board revision or machine configuration.
Intermittent operation
Inspect connectors, cable strain, oxidation, solder joints, and power-supply stability. Mechanical vibration can also affect older board assemblies and their connectors.
X-ray system remains unavailable
Do not bypass safety interlocks. Check the machine’s diagnostic procedure and verify the control-board assembly together with the associated power, control, and safety circuits.
❓ FAQ
Q1: What is the PHOENIX X-RAY BRV-03 + BAS-01?
It is a two-board control assembly identified as BRV-03 + BAS-01 and referenced as IN9S1B1 for Phoenix X-Ray equipment.
Q2: Is this a general-purpose PLC board?
No. It should be treated as a dedicated machine-control assembly for Phoenix X-Ray inspection equipment rather than a general PLC module.
Q3: Is the assembly new or used?
The referenced listing identifies it as Used and states that it was removed from a working production line.
Q4: Can BRV-03 or BAS-01 be purchased separately?
Separate board listings exist for related Phoenix X-Ray boards, but the individual boards should not automatically be considered equivalent to the complete BRV-03 + BAS-01 assembly.
Q5: Can I replace only one board?
Only after confirming the machine configuration and the specific board function. For a direct replacement, matching the original complete assembly is the safer approach.
Q6: Does this board require machine-specific wiring?
Yes. Connector assignment, cable routing, terminal configuration, and associated equipment should be verified against the original installation.
Q7: What should be checked before ordering?
Confirm the BRV-03 and BAS-01 markings, reference IN9S1B1, revision information, connector arrangement, and the Phoenix X-Ray machine model.
Q8: Is the board suitable for radiation-generating equipment?
It is associated with industrial X-ray inspection equipment, but suitability must be confirmed against the exact machine and safety configuration.
📦 Recommended Related PHOENIX X-RAY Models & Components
- PHOENIX X-RAY BVR_03 Vacuum Control Board
- PHOENIX X-RAY BAS01A BAS Board
- PHOENIX X-RAY BMZ6 BMZ5LB0000 200324 Board
- PHOENIX X-RAY BMS5 BMS2LB0004 200363 Power Board
- PHOENIX X-RAY BRV-03 Control Board
- PHOENIX X-RAY BAS-01 Control Board
- PHOENIX X-RAY X|aminer Control Assemblies
- PHOENIX X-RAY Service Driver Boards
- PHOENIX X-RAY Inspection System Interface Boards
- PHOENIX X-RAY Machine Control PCB Assemblies
💡 Spare-Part Recommendation
For legacy X-ray inspection systems, keeping a complete BRV-03 + BAS-01 assembly as a maintenance spare can simplify replacement compared with sourcing individual boards after a machine failure.
For critical production equipment, record the exact board markings, revisions, connector configuration, and machine model when establishing the spare-parts database. This helps prevent a visually similar but electrically different board from being installed during an emergency repair.
When ordering a replacement, always match BRV-03 + BAS-01 / IN9S1B1 against the existing equipment configuration and verify compatibility before commissioning.