Description
🔧 Product Overview
The ProSoft ICX35-HWC-E is an Industrial Cellular Gateway designed for remote access, SCADA connectivity, telemetry, and machine-to-machine communication. It provides cellular connectivity together with Ethernet and serial interfaces, allowing industrial equipment at remote or difficult-to-access locations to communicate with control systems and networks.
The ICX35-HWC-E is the ETSI version of the ICX35-HWC family. It supports 4G LTE cellular communication with 3G fallback and provides an onboard 10/100 Base-T Ethernet port that can be configured for WAN or LAN operation. The gateway also includes a DB9 serial interface for serial tunneling and encapsulation.
ProSoft currently identifies the ICX35-HWC-E as a discontinued ETSI model, making available surplus units useful for maintaining existing installations where replacement with the same hardware is preferred.

⚙️ Key Features
- Industrial cellular gateway for remote automation applications
- ICX35-HWC-E ETSI cellular model
- 4G LTE connectivity with 3G fallback
- LTE, GSM, UMTS/HSPA+, GPRS and EDGE support
- 10/100 Base-T Ethernet interface
- DB9 serial interface
- Serial tunneling and encapsulation
- Dual RP-SMA antenna connectors
- SIM-based cellular activation
- EtherNet/IP and Modbus TCP/IP support
- OpenVPN and IPSec security options
- IP address filtering
- Built-in web server for configuration and diagnostics
- SMS messaging support through compatible PLC/PAC communications
- DIN-rail mounting
- Industrial aluminum enclosure
- Wide 10–30 VDC power input
- Operating temperature up to 70°C
- Discontinued ETSI model suitable for replacement and spare-part applications
📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | ProSoft Technology |
| Model | ICX35-HWC-E |
| Product Type | Industrial Cellular Gateway |
| Product Family | ICX35-HWC |
| Regional Version | ETSI Model |
| Cellular Technology | LTE / GSM / UMTS/HSPA+ / GPRS / EDGE |
| LTE Bands | 1, 3, 7, 8, 20 |
| HSPA/HSPA+ Bands | 1, 2, 5, 8 |
| Ethernet | 1 × 10/100 Base-T RJ45 |
| Serial Interface | 1 × DB9 Female |
| Serial Function | Tunneling & Encapsulation |
| Antenna Interfaces | 2 × RP-SMA Female |
| SIM | SIM Slot |
| Security | OpenVPN Client / IPSec Client / IP Filtering |
| Protocol Support | EtherNet/IP / Modbus TCP/IP |
| Power Input | 10–30 VDC |
| Peak Power Consumption | < 6 W |
| Dimensions | 5.52 × 2.06 × 4.37 in / 14.01 × 5.24 × 11.09 cm |
| Weight | 14.5 oz / 411 g |
| Enclosure | Extruded Aluminum |
| Mounting | DIN Rail Clip |
| Operating Temperature | -40°C to +70°C |
| Humidity | 5–95% RH, non-condensing |
| Shock | 20G operational / 30G non-operational |
| Vibration | 10G, 10–150 Hz |
| Status | Discontinued ETSI Model |
The cellular band information, interfaces, dimensions, environmental specifications, power requirements, and communication features above are taken from ProSoft Technology’s manufacturer documentation.
🌐 Remote Connectivity
The ICX35-HWC-E is designed for installations where PLCs, RTUs, HMIs, and other automation equipment need to be accessed from a remote location.
Typical communication architecture can use the cellular network as the connection between a remote machine and a control center. The Ethernet interface can connect to an industrial network, while the DB9 serial interface can provide access to legacy serial equipment.
The gateway supports EtherNet/IP and Modbus TCP/IP communications, allowing compatible PLC or PAC systems to obtain gateway diagnostic information such as cellular signal and data-related information.
📡 Cellular Communication
The ICX35-HWC-E supports multiple cellular technologies and ETSI-oriented frequency bands:
- LTE Bands 1, 3, 7, 8, 20
- HSPA/HSPA+ Bands 1, 2, 5, 8
- Quad-band EDGE/GPRS/GSM
- SIM-based network activation
Two RP-SMA antenna connectors are provided. Antennas are separate components and should be selected according to the installation and supported cellular network.
🔐 Security & Remote Access
Security functions include OpenVPN client, IPSec client, and IP address filtering. The gateway also supports secure remote connectivity architectures through ProSoft/Belden remote-access solutions.
The built-in web server provides access to local or remote configuration, monitoring, and wireless network diagnostics.
🏭 Typical Applications
The ICX35-HWC-E can be found in applications such as:
- Remote PLC access
- SCADA systems
- Remote telemetry
- Water and wastewater systems
- Oil and gas equipment
- Pumping stations
- Industrial machinery
- Remote production equipment
- OEM machine monitoring
- M2M communication
- Legacy serial equipment connected to cellular networks
- Distributed industrial automation
For geographically dispersed installations, cellular communication can reduce the need for technicians to travel to remote equipment for routine diagnostics or troubleshooting.
🔌 Installation & Replacement Notes
Before replacing an existing ICX35-HWC-E, verify the exact regional model and cellular-band requirements. The E model is specifically the ETSI version and should not automatically be substituted with the FCC-oriented ICX35-HWC-A without checking the application.
Recommended replacement procedure:
- Confirm the original part number is ICX35-HWC-E.
- Verify the cellular network and supported LTE bands.
- Confirm the SIM card and carrier requirements.
- Check the existing antenna arrangement.
- Verify the 10/100 Ethernet connection.
- Check whether the application uses the DB9 serial interface.
- Record the existing network and VPN configuration.
- Verify the required power supply is within 10–30 VDC.
- Confirm adequate cellular signal at the installation location.
- Test Ethernet, serial communication, cellular registration, and remote access after installation.
Because the ICX35-HWC-E is discontinued, customers replacing an operating unit should verify compatibility carefully before changing to another cellular gateway model. ProSoft identifies the ICX35-HWC-A as the currently available FCC version while the ICX35-HWC-E is discontinued.
❓ Frequently Asked Questions
Q: What is ProSoft ICX35-HWC-E?
A: It is an Industrial Cellular Gateway designed for remote connectivity, SCADA, telemetry, M2M communication, and industrial equipment access.
Q: Is ICX35-HWC-E discontinued?
A: Yes. ProSoft Technology currently identifies the ICX35-HWC-E as a discontinued ETSI model.
Q: What cellular technology does it support?
A: It supports LTE, GSM, UMTS/HSPA+, GPRS, and EDGE, with the exact available bands depending on the ICX35-HWC-E regional configuration.
Q: Does it have an Ethernet port?
A: Yes. It provides one 10/100 Base-T Ethernet port with an RJ45 connector.
Q: Does it support serial communication?
A: Yes. The unit has one female DB9 serial port supporting serial tunneling and encapsulation.
Q: What PLC protocols are supported?
A: ProSoft specifies EtherNet/IP and Modbus TCP/IP support for the ICX35-HWC family.
Q: What is the power requirement?
A: The external power input is 10–30 VDC, with peak power consumption below 6 W.
Q: How is the gateway mounted?
A: The enclosure includes a DIN-rail clip for industrial installation.
Q: Are antennas included?
A: ProSoft specifies two RP-SMA antenna connectors and notes that antennas are sold separately.
Q: Can ICX35-HWC-A replace ICX35-HWC-E?
A: They are different regional variants. The A model is the FCC version and the E model is the ETSI version. Cellular bands and regulatory requirements should be checked before substitution.
📦 Recommended ProSoft Models
For customers maintaining ProSoft communication and industrial networking systems, these related models are worth considering as spare-part references:
- ICX35-HWC-E — ETSI Industrial Cellular Gateway
- ICX35-HWC-A — FCC Industrial Cellular Gateway
- PLX35-NB2 — Industrial Network Bridge
- PLX35-NB2-E — Industrial Network Bridge variant
- MVI56E-MNETC — Modbus TCP/IP Communication Module
- MVI56E-MNETCR — Modbus TCP/IP Communication Module
- MVI56E-ETHERNET — Ethernet Communication Module
- MVI56E-GEC — Generic Ethernet Communication Module
- MVI69E-MNETC — Modbus TCP/IP Communication Module
- MVI94-MCM — Modbus Communication Module
Model compatibility should always be checked against the PLC platform, network architecture, communication protocol, and installed application before selecting a replacement.
🔍 Inspection Before Shipment
For a replacement or spare ICX35-HWC-E, recommended inspection includes:
- Part number and model verification
- Nameplate inspection
- Housing inspection
- DIN-rail mounting clip inspection
- RJ45 Ethernet port inspection
- DB9 serial port inspection
- RP-SMA connector inspection
- DC power input inspection
- Cellular registration test where supported
- Ethernet communication test
- Serial communication test
- Web configuration interface check
- LED/status indicator inspection
- Firmware/version recording
- Serial number recording
- Final functional test and ESD-safe packaging
The ICX35-HWC-E is especially relevant for maintaining existing installations that were designed around the ETSI cellular version. Since ProSoft has discontinued this model, verified surplus stock can be useful when an existing system requires a like-for-like replacement.