Description
⚙️ Product Overview
The SCHENCK PROCESS VSE20100 is a DISOCONT system unit designed for measurement and control applications. The listed configuration combines the VSE20100 hardware with VMD20150 software, providing a controller suitable for weighing, feeding, and material-flow control applications.
The VSE20100 is designed as a programmable system unit rather than a simple display module. Its configuration and application software determine the specific measurement and control function. The VMD20150 software is associated with MULTICOR applications and can be loaded into the VSE20100 controller.
The current listing identifies the unit as VSE20100 + VMD20150, with Germany listed as the country of origin and a used condition.

🔧 Key Features
- ⚙️ Schenck Process DISOCONT system unit
- 🔢 Model: VSE20100
- 💾 Software configuration: VMD20150
- 📊 Designed for measurement and control functions
- ⚖️ Suitable for weighing and feeding-related applications
- 🔌 Load-cell measurement capability
- 🌐 Expandable with fieldbus communication
- 🧠 Application functionality determined by installed software
- 🛠️ Suitable for replacement and maintenance of existing DISOCONT installations
- 🇩🇪 Country of origin: Germany
📊 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | SCHENCK PROCESS |
| Model | VSE20100 |
| Software | VMD20150 |
| Product Name | DISOCONT Control / Indicator System |
| Series | DISOCONT |
| Main Function | Measurement and Control |
| Typical Application | Weighing, feeding and material-flow control |
| Load Cell Input | ±6 V field excitation/input system |
| Resolution | Up to 24-bit for load-cell measurement |
| Operating Temperature | -25°C to +50°C |
| Storage Temperature | -25°C to +60°C |
| Protection Rating | IP00, when installed as specified |
| Power Supply | 24–300 VDC ±15% or 110–230 VAC depending configuration |
| Power Consumption | Approx. 20 W |
| Condition / Status | Used |
| Country of Origin | Germany |
🏭 Typical Applications
The VSE20100 can be integrated into industrial material-handling and process-control equipment where accurate measurement and controlled feeding are required.
Typical applications include:
- ⚖️ Continuous weighing systems
- 🪨 Bulk-material handling
- 🏭 Process weighing
- 🚚 Material feeding systems
- 🔄 Gravimetric feeders
- 📦 Bulk solids processing
- 🧱 Cement and building-material production
- ⛏️ Mining and mineral-processing equipment
- 🌾 Industrial material dosing
- 🔌 PLC and fieldbus-connected process systems
🔌 Control & Measurement Functions
The VSE20100 system unit is designed to perform measurement and control functions within the DISOCONT architecture. The system can be configured for different applications through its software.
For load-cell applications, the documented VSE20100 architecture supports a load-cell field supply/input of approximately ±6 V, with 1–3 mV/V load-cell sensitivity depending on application software. Up to four 350 Ω load cells can be supported, with six-wire connection and a measurement resolution of up to 24 bits.
The controller can also be expanded with communication interfaces. DISOCONT documentation identifies options such as PROFIBUS, Modbus, DeviceNet and PROFINET within the broader system family.
The VMD20150 software is particularly relevant to MULTICOR applications and is identified by Schenck Process as software that can be downloaded into a VSE20100 controller.
💾 Software & Configuration
Software compatibility is an important consideration when replacing a VSE20100.
The same VSE20100 hardware can be configured for different applications using appropriate software. Therefore, the controller’s installed software, memory configuration, fieldbus option, and application parameters should be compared with the existing system before replacement.
For a VSE20100 configured with VMD20150, verify:
- Software version
- Application configuration
- Memory card or stored parameter configuration
- Fieldbus interface
- Local bus address
- Connected weighing equipment
- Existing calibration parameters
A replacement controller with the correct hardware but an incorrect application configuration may require software loading and parameter restoration before commissioning.
🛠️ Installation & Maintenance
Before Installation
- Confirm the controller model is VSE20100.
- Verify that VMD20150 is the required application software.
- Record the existing software and hardware revision.
- Document all terminal and fieldbus connections.
- Back up application parameters and calibration data where possible.
- Confirm the supply voltage of the existing installation.
During Installation
- Disconnect power before wiring.
- Observe appropriate ESD precautions when handling the controller.
- Confirm load-cell wiring and polarity.
- Check fieldbus wiring and termination.
- Verify the local bus address where applicable.
- Install the controller in the appropriate Schenck Process enclosure or approved cabinet arrangement.
The VSE20100 documentation specifies that the system unit should be installed in a suitable housing so that live parts are not accessible during normal operation.
Commissioning
After installation:
- Confirm controller power-up.
- Check load-cell signal stability.
- Verify zero and span/calibration parameters.
- Confirm communication with connected devices.
- Test feeding or weighing functions.
- Check alarms and diagnostic information.
- Compare measured values with an approved reference.
❓ Common Questions & Answers
Q1: What is the main model number?
A: The main controller is VSE20100.
Q2: What does VMD20150 represent?
A: VMD20150 is application software associated with MULTICOR functionality and can be loaded into a VSE20100 controller.
Q3: Is VSE20100 only an indicator?
A: No. It is a DISOCONT system unit capable of performing measurement and control functions.
Q4: Can it be used for weighing applications?
A: Yes. The VSE20100 architecture supports load-cell measurement and is used in weighing and feeding applications.
Q5: Can the VSE20100 communicate with a PLC?
A: Depending on the installed communication option, DISOCONT systems can support fieldbus interfaces for integration with higher-level automation systems.
Q6: Is the software important when replacing the unit?
A: Yes. The VSE20100 is configurable through application software, so the software version and application configuration should match the existing installation.
Q7: What should be checked before ordering?
A: Confirm VSE20100, VMD20150, hardware revision, software version, fieldbus option, load-cell configuration, and existing system parameters.
Q8: What industries use this type of equipment?
A: Typical applications include bulk-material handling, mineral processing, cement, building materials, feeding systems, and other continuous weighing processes.
⭐ Recommended SCHENCK PROCESS Models
For DISOCONT and Schenck Process spare-parts planning, related components include:
- SCHENCK PROCESS VSE20100 – DISOCONT System Unit
- SCHENCK PROCESS VSE20100 + VMD20150 – MULTICOR Control Configuration
- SCHENCK PROCESS VIO20150 – I/O System Configuration
- SCHENCK PROCESS VIO 20150 – DISOCONT I/O Module
- SCHENCK PROCESS VET20101 – Fieldbus Interface
- SCHENCK PROCESS VHM20100 – DISOCONT Touchscreen
- SCHENCK PROCESS VHM20110 – Portable Operator Terminal
- SCHENCK PROCESS VPB28020 – PROFIBUS Interface
- SCHENCK PROCESS VSS28020 – Modbus Interface
- SCHENCK PROCESS VPC20150 – EasyServe Service Software
📦 Spare-Parts Recommendation
For installations using the SCHENCK PROCESS DISOCONT VSE20100, it is useful to maintain spare controllers together with compatible software, communication interfaces, load-cell components, and operator panels.
When replacing a VSE20100 + VMD20150, matching the application software is just as important as matching the hardware. Before commissioning, verify the controller configuration, fieldbus interface, calibration data, and connected weighing equipment to ensure the replacement operates correctly within the existing process-control system.