Description
Product Description
The Triconex 3625A is a 32-point Triple Modular Redundant (TMR) Digital Output Module designed for Tricon safety instrumented systems. It provides discrete output signals for controlling field devices such as solenoid valves, relays, shutdown circuits, and other industrial actuators.
The module supports supervised and non-supervised output configurations and is designed for both energize-to-trip and de-energize-to-trip applications. Its output architecture supports safety-related control functions while providing diagnostic information for monitoring field circuit conditions.
The 3625A is an updated version of the 3625 Digital Output Module. Its field power arrangement separates the 32 output points into two groups of 16 while maintaining a common return. This arrangement provides greater flexibility in field power distribution. The 3625A is fully compatible with the applications supported by the 3625, subject to the applicable system and termination-panel requirements.
Designed for Tricon v10.2 and later systems, the 3625A is suitable for maintenance and replacement projects involving existing Tricon safety control installations in oil and gas, petrochemical, power generation, and other process industries.

3625A
Key Technical Specifications
- Brand: Triconex
- Model: 3625A
- Product Type: TMR Supervised / Non-Supervised Digital Output Module
- Module Function: Safety System Digital Output
- Output Points: 32
- Output Configuration: Commoned outputs
- Operating Architecture: Triple Modular Redundancy (TMR)
- Output Application: Energize-to-trip and de-energize-to-trip
- Nominal Field Voltage: 24 V DC
- Recommended Voltage Range: 16–32 V DC
- Maximum Field Voltage: 36 V DC
- Maximum Current per Point: 1.70 A ±10%
- Surge Current: 5 A for 7 ms
- Total Output Current: 10 A per termination panel
- Minimum Required Load: 10 mA
- Maximum Output Leakage: 2.0 mA at 24 V DC; 2.5 mA at 32 V DC
- Logic Power Consumption: Less than 13 W
- System-to-Field Isolation: 1,500 V DC minimum
- Field Power Arrangement: Two groups of 16 points with a common return
- Point Supervision: Programmable per output point
- Fault Detection: Programmable short-circuit and open-circuit detection thresholds
- Output Protection: Self-protection against overvoltage, overtemperature, and overcurrent
- Status Indicators: PASS, FAULT, LOAD, and ACTIVE, plus point-level status indication
- Compatible System: Tricon v10.2 and later
- Field Termination: Compatible 16-point commoned field termination panels
Key Features
- 32 digital output points for distributed safety-related control.
- TMR architecture supports fault-tolerant output operation.
- Configurable supervised and non-supervised output modes.
- Supports energize-to-trip and de-energize-to-trip applications.
- Two independent groups of 16 field power points with a common return.
- Programmable point supervision for field circuit diagnostics.
- Detects configured open-circuit and short-circuit conditions.
- Self-protected output switching against overcurrent, overvoltage, and overtemperature.
- Dedicated module and channel status indicators.
- Fully compatible with the applications of the earlier 3625 module.
Application Scenarios and Pain Points
Emergency Shutdown Systems: Provides discrete output control for shutdown solenoids, trip relays, and other safety-related field devices.
Oil and Gas Processing: Supports safety logic outputs associated with process isolation, equipment shutdown, and emergency response functions.
Petrochemical Plants: Interfaces safety controllers with field actuators used in process protection and hazardous operating environments.
Power Generation: Supports discrete control and shutdown functions in compatible turbine, generator, and auxiliary protection systems.
Field Circuit Monitoring: Supervised configurations help identify selected field wiring faults, including open circuits and short circuits.
Legacy Tricon System Maintenance: Provides a replacement option for existing 3625 applications when the system version, termination panels, field power arrangement, and configuration have been verified.
Installation and Commissioning
- Confirm the complete module designation, 3625A, and verify that the target Tricon system is version 10.2 or later.
- Check the installed Tricon chassis and compatible 16-point commoned field termination panels.
- Review the system drawings and confirm the required energize-to-trip or de-energize-to-trip configuration.
- Verify the 24 V DC field power supply and ensure that the voltage remains within the specified operating range.
- Check the two groups of 16 output points and their common-return arrangement.
- Follow the manufacturer’s approved procedures for module installation and termination-panel wiring.
- Configure output supervision and short/open circuit detection thresholds as required by the safety application.
- Verify that the total output current does not exceed 10 A per termination panel.
- Check module status indicators and confirm that the controller recognizes the installed output module.
- Test each configured output point using an approved commissioning procedure.
- Verify field-device response, trip logic, alarm reporting, and fault diagnostics before returning the safety system to service.
Important field power consideration: Tricon documentation recommends wiring the termination panels in parallel and powering them from a single set of redundant field power sources. If four independent field power sources are used, their voltages must remain within 5% of the highest supplied voltage to avoid potential voter faults and alarms.
Daily Maintenance
- Monitor PASS, FAULT, LOAD, and ACTIVE indicators during routine inspections.
- Review field circuit alarms and diagnostic information.
- Inspect termination-panel wiring and field power connections.
- Check the condition of output cables, connectors, and terminal blocks.
- Monitor field supply voltage and verify that the two 16-point groups receive the correct power.
- Investigate abnormal output leakage or unexpected load indications.
- Confirm that connected actuators respond correctly during scheduled functional testing.
- Maintain records of output assignments, supervision settings, and maintenance activities.
Troubleshooting and FAQ
Q1: What is the main function of the Triconex 3625A?
It is a 32-point TMR Digital Output Module used to control field devices through a Tricon safety instrumented system.
Q2: What is the difference between the 3625 and 3625A?
The 3625A separates field power into two groups of 16 output points while maintaining a common return. It is fully compatible with the applications of the earlier 3625 module.
Q3: Can the 3625A operate in supervised and non-supervised modes?
Yes. The module supports both configurations. Point supervision can be programmed according to the application requirements.
Q4: What is the nominal field voltage?
The nominal field voltage is 24 V DC. The recommended operating range is 16–32 V DC, with a maximum voltage of 36 V DC.
Q5: How much current can each output point handle?
The specified maximum current is 1.70 A ±10% per point, with a 5 A surge rating for 7 ms. The total output current is limited to 10 A per termination panel.
Q6: Which Tricon system versions support the 3625A?
The module is specified for Tricon v10.2 and later systems. Verify the installed system version before ordering.
Q7: Can the 3625A replace a 3625?
Yes. Manufacturer documentation states that the 3625A is fully compatible with all applications of the 3625. The termination-panel wiring and field power arrangement must still be checked.
Q8: Does the module require a separate termination panel?
Yes. It is designed to work with compatible field termination panels. Confirm the exact panel type, cable interface, and wiring arrangement before installation.
Q9: What should be checked if a field output does not operate?
Check the field power supply, output wiring, connected load, termination-panel connections, module diagnostics, and configured output supervision. Also verify that the output current and field voltage remain within the specified limits.
Safety Precautions
- Installation and maintenance must be performed by qualified safety-system technicians.
- Follow the approved Tricon system maintenance and module replacement procedures.
- Isolate field power and observe site electrical safety requirements before handling field wiring.
- Verify the termination-panel type and common-return arrangement.
- Do not exceed the specified per-point or total termination-panel current limits.
- Ensure redundant field power sources meet the manufacturer’s voltage-matching requirements.
- Do not bypass safety interlocks, trip circuits, or output supervision functions.
- Perform functional and proof testing according to the plant’s safety lifecycle procedures.
- Never return the safety system to service until the approved verification process is complete.
Recommended Related Models and Components
The following products are related to Tricon safety-system digital I/O and system infrastructure. They are not all direct replacements for the 3625A.
- 3625 – 32-Point TMR Digital Output Module
- 3624 – 16-Point TMR Digital Output Module
- 3623 – 16-Point TMR Digital Output Module
- 3623T – TMR Digital Output Module
- 3604E – Digital Input Module
- 3601E – Digital Input Module
- 3503E – Digital Input Module
- 3504E – Digital Input Module
- 3505E – Digital Input Module
- 3700A – Analog Input Module
- 3721 – Analog Input Module
- 3805E – Analog Output Module
- 8312 – Tricon Power Supply Module
- 8311 – Tricon Power Supply Module
- 3008 – Tricon Main Processor Module
Verify the exact hardware revision, chassis generation, termination-panel compatibility, and system configuration before selecting any related model for replacement.
Inspection and Quality Control
Before installation, verify the module identification label and inspect the housing, backplane connector, and associated termination-panel connections. Check for corrosion, physical damage, contamination, or signs of overheating.
Functional testing should be performed in a compatible Tricon v10.2 or later environment. Verify module recognition, output-point operation, field voltage, load response, status indicators, and configured supervision diagnostics.
For safety-related applications, testing must follow the approved site procedures and manufacturer documentation. Record the module identification, hardware revision, termination-panel type, field power arrangement, and inspection results.
Actual product condition, revision, and included accessories should be confirmed against the individual unit.



