Sale!

TRICONEX | 4352AN | Tricon Communication Module (TCM)

Original price was: $10,000.00.Current price is: $666.00.

Product NO:TRICONEX 4352AN

Brand:TRICONEX

Delivery time: In stock

Product status: Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

Product Description

The TRICONEX 4352AN is a Tricon Communication Module (TCM) designed for Tricon V10 safety instrumented systems. It provides communication interfaces between the Tricon controller and external systems, including operator stations, engineering workstations, distributed control systems, peer Tricon controllers, and Modbus-compatible devices.

The 4352AN combines two fiber-optic Ethernet ports with four serial communication ports. Its fiber-optic interfaces support 100 Mbps Ethernet communication through MT-RJ connectors, while the serial interfaces support RS-232 and RS-485 communication through DB-9 connectors.

The module supports multiple industrial communication protocols, including Modbus, TCP/IP, TriStation, TSAA, SNTP, and peer-to-peer communication. Individual serial ports can be configured for supported communication functions, allowing integration with different plant equipment and supervisory systems.

The 4352AN is the nuclear-qualified N-designated version associated with the Tricon V10 configuration. It should not be confused with the standard 4352A or 4352B models. Before installation or replacement, verify the nuclear qualification requirements, system revision, logical slot assignment, communication configuration, and module identification.

TRICONEX 4352AN

TRICONEX 4352AN

Product Datasheet

  • Brand: TRICONEX
  • Model: 4352AN
  • Product Name: Tricon Communication Module (TCM)
  • Product Type: Industrial Communication Interface Module
  • System Family: Tricon V10 Safety Instrumented System
  • Module Function: Controller and external-system communication
  • Network Interfaces: 2 fiber-optic Ethernet ports
  • Fiber Connector: MT-RJ
  • Fiber Type: 62.5/125 µm multimode fiber
  • Ethernet Speed: 100 Mbps
  • Serial Interfaces: 4 independent serial ports
  • Serial Standards: RS-232 / RS-485
  • Serial Connectors: DB-9
  • Maximum Serial Baud Rate: 115.2 kbps per port
  • Port Isolation: 500 V DC
  • Supported Protocols: Modbus, TCP/IP, ICMP, SNTP, TSAA, TriStation, peer-to-peer UDP/IP, and peer-to-peer time synchronization
  • Modbus Functions: 01, 02, 03, 04, 05, 06, 07, 08, 15, and 16
  • Status Indicators: PASS, FAULT, ACTIVE, FIRM, LINK, TX, and RX
  • Maximum TCM Quantity: 4 per Tricon system, arranged in two logical slots
  • Hot-Spare Function: Not supported
  • Online Maintenance: Faulty TCM replacement is supported under the applicable system maintenance procedure
  • Configuration Software: TriStation 1131
  • Debug Interface: Dedicated Triconex service/debug port
  • Power Supply: Provided through the Tricon system backplane
  • Operating Temperature: Confirm against the applicable 4352AN hardware documentation
  • Dimensions: Verify against the original mechanical drawing
  • Weight: Verify from the actual unit
  • Country of Origin: Confirm from the product label
  • Product Status: Legacy Tricon V10 component; verify current availability
  • Condition: Confirm whether supplied as new surplus, used, or refurbished

 

Technical Features & Specifications

Dual Fiber-Optic Ethernet Interfaces

The 4352AN provides two fiber-optic Ethernet ports, NET 1 and NET 2, using MT-RJ connectors and 62.5/125 µm multimode fiber.

Both ports support 100 Mbps communication. Fiber-optic connectivity helps reduce electromagnetic interference and ground-potential problems associated with long copper communication links.

NET 1 additionally supports peer-to-peer UDP/IP and peer-to-peer time synchronization functions.

Four Independent Serial Communication Ports

The module provides four RS-232/RS-485 serial ports with DB-9 connectors. Each port can be configured independently for supported communication functions.

  • Serial Port 1: Modbus or Trimble GPS interface.
  • Serial Port 2: Modbus interface.
  • Serial Port 3: Modbus interface.
  • Serial Port 4: TriStation 1131 or Modbus interface.

The maximum serial communication speed is 115.2 kbps per port. Confirm the electrical interface, pin assignments, baud rate, parity, and termination requirements before connecting external devices.

Modbus Communication

The TCM supports Modbus master and slave communication over compatible serial and Ethernet interfaces.

Supported Modbus functions include:

  • Function 01: Read Coil Status
  • Function 02: Read Input Status
  • Function 03: Read Holding Registers
  • Function 04: Read Input Registers
  • Function 05: Modify Coil Status
  • Function 06: Modify Register Content
  • Function 07: Read Exception Status
  • Function 08: Loopback Diagnostic Test
  • Function 15: Force Multiple Coils
  • Function 16: Preset Multiple Registers

Tricon controller variables must be assigned the appropriate Modbus aliases in the TriStation engineering environment before external devices can access them.

TriStation and TSAA Connectivity

The 4352AN supports TriStation communication for engineering and controller-related functions. TSAA communication supports data exchange with compatible Triconex applications and external systems.

Network configuration, IP addressing, communication permissions, and software compatibility should be checked against the installed Tricon V10 configuration.

Electrical Isolation

The serial communication ports provide 500 V DC isolation according to the TCM specifications. This helps separate external communication equipment electrically from the controller-side communication circuitry.

Correct grounding, cable shielding, and interface selection remain necessary for reliable operation.

System Capacity and Logical Slot Configuration

A Tricon system supports up to four TCM modules arranged in two logical slots. Different TCM models must not be mixed within the same logical slot.

The system supports up to 32 Modbus masters or slaves in total across the supported network and serial interfaces.

The TCM does not have a dedicated hot-spare function. A faulty module can be replaced while the controller remains online when the system configuration and approved maintenance procedure permit it.

 

Application Scenarios & Pain Points

  • Nuclear-qualified process automation: Provides communication connectivity in applicable nuclear-qualified Tricon V10 installations.
  • Oil and gas safety systems: Connects Tricon controllers with supervisory systems and compatible Modbus equipment.
  • Emergency shutdown systems: Supports communication between safety controllers and external monitoring or control systems.
  • Distributed control systems: Exchanges selected process and status information between Tricon and DCS platforms.
  • Power generation: Supports communication with compatible plant monitoring and supervisory equipment.
  • Engineering and maintenance: Provides TriStation communication for supported controller engineering functions.
  • Peer controller communication: Supports data exchange between compatible Tricon systems.

Typical maintenance challenges include fiber-optic link failures, incorrect serial-port settings, Modbus address conflicts, incompatible TCM models in logical slots, and network configuration errors.

 

First-Time Installation Checklist

  1. Verify the complete model designation: TRICONEX 4352AN.
  2. Confirm that the target system is an approved Tricon V10 configuration.
  3. Check the nuclear qualification and hardware revision requirements for the installation.
  4. Confirm the assigned logical slot and existing TCM configuration.
  5. Verify that the selected logical slot does not contain an incompatible TCM model.
  6. Inspect the module connector, retaining hardware, and front-panel indicators.
  7. Confirm MT-RJ fiber connectors and 62.5/125 µm multimode fiber compatibility.
  8. Check fiber polarity, cleanliness, routing, and link status.
  9. Verify serial cable pinouts, RS-232/RS-485 selection, and communication parameters.
  10. Check IP addresses, Modbus aliases, and communication protocol settings.
  11. Verify TriStation 1131 connectivity and controller communication.
  12. Review PASS, FAULT, ACTIVE, FIRM, LINK, TX, and RX indicators.
  13. Test communication with representative external devices.
  14. Record the installed module revision and approved configuration before returning the system to service.

 

Daily Maintenance

  • Monitor PASS, FAULT, ACTIVE, and FIRM indicators.
  • Check LINK indicators on both fiber-optic Ethernet ports.
  • Review TX and RX activity for communication interruptions.
  • Inspect fiber connectors for contamination or physical damage.
  • Check serial communication cables and DB-9 connectors.
  • Monitor Modbus communication errors and timeout events.
  • Verify network addressing and communication configuration after approved system changes.
  • Maintain backups of TriStation projects and communication settings.
  • Record module faults, replacements, and maintenance activities.

 

Troubleshooting & Frequently Asked Questions

Q1: What is the main function of the TRICONEX 4352AN?

It is a Tricon Communication Module that connects a Tricon V10 safety controller to external networks, serial devices, engineering workstations, and compatible supervisory systems.

Q2: How many Ethernet ports does the 4352AN provide?

It provides two 100 Mbps fiber-optic Ethernet ports with MT-RJ connectors.

Q3: How many serial ports are available?

Four independent RS-232/RS-485 serial ports are provided, each using a DB-9 connector and supporting speeds up to 115.2 kbps.

Q4: What is the difference between 4352AN and 4352A?

The 4352AN is the N-designated version associated with the nuclear-qualified Tricon V10 configuration. The 4352A is a standard fiber-optic TCM variant. Do not substitute one for the other without confirming the applicable system qualification and hardware requirements.

Q5: Does the 4352AN support Modbus TCP?

Yes. Its Ethernet interfaces support Modbus TCP/IP master and slave communication, subject to the configured network and controller application.

Q6: Can the 4352AN communicate with a DCS?

Yes. It can exchange data with compatible external systems through supported Modbus and other communication services. The DCS interface and data mapping must be engineered and tested.

Q7: Does the TCM support hot-spare operation?

No. The TCM hot-spare function is not supported. However, a faulty TCM can be replaced while the controller remains online under the applicable system maintenance procedure.

Q8: Why is the fiber-optic communication link unavailable?

Check the fiber type, connector cleanliness, fiber polarity, cable condition, network configuration, and LINK indicators. Confirm that both connected devices support the required 100 Mbps fiber interface.

Q9: Can different TCM models be installed together?

Different TCM models must not be mixed within the same logical slot. Review the Tricon V10 system configuration before adding or replacing a module.

 

Safety Precautions

  • Follow the approved maintenance procedures for nuclear-qualified or safety-related installations.
  • Verify the exact module designation and qualification requirements before replacement.
  • Do not assume that standard 4352A or 4352B modules are interchangeable with 4352AN.
  • Isolate or manage external communication circuits according to plant procedures.
  • Use the correct fiber-optic cable and connector type.
  • Inspect and clean fiber connectors using approved optical-fiber maintenance tools.
  • Verify serial interface standards and cable pin assignments before connection.
  • Do not change communication parameters without reviewing the impact on connected systems.
  • Do not bypass controller diagnostics or safety-system communication controls.
  • Perform post-maintenance communication checks and document the results.

 

Recommended Related Models & Components

The following products belong to the Tricon communication and safety-system hardware families. They are related components, not all direct replacements for the 4352AN.

  1. TRICONEX 4351A – Tricon Communication Module, Copper Ethernet
  2. TRICONEX 4351B – Tricon Communication Module, Copper Ethernet
  3. TRICONEX 4352A – Tricon Communication Module, Fiber Ethernet
  4. TRICONEX 4352B – Tricon Communication Module, Fiber Ethernet
  5. TRICONEX 4353 – Tricon Communication Module with Embedded OPC Server
  6. TRICONEX 4354 – Fiber-Optic Tricon Communication Module with Embedded OPC Server
  7. TRICONEX 4119A – Enhanced Intelligent Communication Module
  8. TRICONEX 4119AN – Nuclear-Qualified Enhanced Intelligent Communication Module
  9. TRICONEX 4329 – Network Communication Module
  10. TRICONEX 4329N – Nuclear-Qualified Network Communication Module
  11. TRICONEX 4609 – Advanced Communication Module
  12. TRICONEX 4609N – Nuclear-Qualified Advanced Communication Module
  13. TRICONEX Tricon V10 Main Chassis – Controller and I/O installation platform
  14. TRICONEX TriStation 1131 – Controller configuration and engineering software
  15. TRICONEX 4352AN Fiber-Optic Communication Cable Assembly – Compatible optical communication accessory
about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.