Description
The Vibro-Meter VM600 IOC4T (part number 200-560-000-113) is a high-reliability Input/Output (I/O) Card manufactured by Vibro-Meter (Meggitt Sensing Systems / Parker Hannifin) for the VM600 Series Machinery Protection System (MPS).
Installed in the rear of a VM600 rack directly behind its corresponding MPC4 (Machinery Protection Card), the IOC4T acts as the primary signal interface bridge. It manages raw dynamic vibration inputs, speed/tachometer channels, buffered transducer outputs, analog control loops, and hardware alarm relay switching for critical turbomachinery protection.
Technical Specifications
| Parameter | Specification |
| Manufacturer | Vibro-Meter / Meggitt Sensing Systems (Parker Hannifin) |
| System Platform | VM600 Series Machinery Protection System (MPS) |
| Model / Type | IOC4T Input/Output Interface Card |
| Part / Order Code | 200-560-000-113 |
| Dynamic Signal Inputs | 4 channels (for proximity probes, accelerometers, velocity sensors) |
| Speed / Tachometer Inputs | 2 channels |
| Analog Outputs | 4 channels, independently configurable (0 to 10 V or 4 to 20 mA via jumpers) |
| Alarm Relay Outputs | 4 programmable mechanical relays (form C contacts, 250 V AC / 5 A max) |
| Digital Outputs | 32 programmable open-collector outputs (for RLC16/IRC4 expansion cards) |
| Power Requirements | +5 V DC, ±12 V DC (derived from VM600 rack backplane buses) |
| Operating Temperature | -25°C to +65°C (-13°F to +149°F) |
| Enclosure / Form Factor | 6U Eurocard, rear-rack mount module (approx. 0.25 kg) |
Core Features & Operating Capabilities
- MPC4 Card Integration: Operates in slave mode, communicating directly via a high-speed Industry Pack (IP) interface with its paired front-slot MPC4 protection card to route, buffer, and process vibration signals.
- Comprehensive Signal Conditioning: Provides robust surge suppression and electromagnetic compatibility (EMC/EMI) filtering across all incoming field sensor lines and outgoing control loops.
- Buffered Raw & Processed Outputs: Exposes raw unintegrated vibration signals for diagnostic analyzers alongside software-scaled analog outputs (0–10 V or 4–20 mA) mapped directly to host DCS or SCADA systems.
- Onboard Alarm Switching: Features four local programmable alarm relays that can be assigned under software control to trip conditions, common alerts, or system fault monitoring.
- Hot-Swappable Rear Design: Engineered for live insertion and extraction within standard VM600 rack configurations (such as ABE04x or ABE056 enclosures) without interrupting adjacent channel loops.
Related Vibro-Meter VM600 Hardware Components
- MPC4 (200-510-000-Cc) — VM600 4-Channel Machinery Protection Card.
- CPUM / IOCN — VM600 System Controller and Communications Interface Card Pair.
- AMC8 / IOC8T — 8-Channel Temperature and Process Monitoring Card Pair.
- ABE04x / ABE056 — Standard 19-inch 6U VM600 System Racks