Description
The Woodward 8440-2151 is an LS-522-5/P1 Version 2 Circuit Breaker Control and Protection Module designed for power generation and complex power-management applications. The LS-522 is the display version of the LS-5 V2 family and is configured for control and protection of two circuit breakers. The 5 A version provides three-phase plus neutral voltage measurement for system A/B and three-phase or single-phase current measurement. The module also provides discrete inputs, relay outputs, an isolated 0/4–20 mA input, CAN communication, and RS-485 communication. Configuration can be performed through the integrated HMI or an external PC.
Product Datasheet
| Specification | Details |
|---|---|
| Brand | Woodward |
| Model | 8440-2151 |
| Platform | LS-522-5/P1 |
| Series | LS-5 Circuit Breaker Control & Protection V2 |
| Product Name | Circuit Breaker Control & Protection Module |
| Functional Type | Version 2 Display Breaker Module |
| Rated Current Version | 5 A |
| Breaker Configuration | Two-breaker / multibreaker control |
| Voltage Measurement | 3-Phase + Neutral, System A/B |
| Current Measurement | 3-Phase / 1-Phase, System A/B |
| Discrete Inputs | 8 |
| Relay Outputs | 6 |
| Analog Input | 1 × 0/4–20 mA, isolated |
| CAN Interface | 1 |
| RS-485 Interface | 1 |
| Power Supply | 12/24 VDC |
| Voltage Measurement Frequency | 50/60 Hz |
| Configuration | Integrated HMI or external PC |
| Product Status | Legacy |
| Condition | NSFP – New Surplus Factory Package |
Key Features
- Woodward LS-5 V2 Circuit Breaker Control & Protection platform
- Part number 8440-2151
- LS-522-5/P1 display version
- 5 A current-input version
- Designed for two-breaker control applications
- Three-phase plus neutral voltage measurement
- System A/B voltage and current monitoring
- 8 discrete inputs
- 6 relay outputs
- Isolated 0/4–20 mA analog input
- CAN communication interface
- RS-485 communication interface
- Integrated display/HMI
- Configurable through the HMI or external PC
- 50/60 Hz voltage measurement
- Suitable for utility, generator, and power-management applications
Common Questions & Answers
Q: What is Woodward 8440-2151?
A: It is the LS-522-5/P1 Version 2 Display Breaker Control Module from Woodward’s LS-5 Circuit Breaker Control & Protection family.
Q: What does LS-522-5/P1 mean?
A: LS-522 identifies the display version configured for two-breaker applications, while the 5/P1 designation identifies the 5 A P1 configuration. Woodward documentation maps 8440-2151 to LS-522-5/P1.
Q: How many circuit breakers can the LS-522 control?
A: The LS-522 is identified as a two-breaker display/control version.
Q: What communication interfaces are available?
A: The 8440-2151 provides one CAN interface and one RS-485 interface.
Q: Does it support current measurement?
A: Yes. The module supports three-phase or single-phase system A/B current measurement, with the 8440-2151 being the 5 A version.
Q: What is the condition of this listing?
A: The supplied listing identifies the item as NSFP, meaning New Surplus Factory Package.
Troubleshooting & Safety
Disconnect and isolate all applicable AC and DC power sources before installation or wiring. Circuit-breaker control equipment can interface with hazardous generator, utility, and control voltages, so follow site lockout/tagout procedures and verify the absence of hazardous voltage with properly rated test equipment.
Before replacement, verify the complete 8440-2151 / LS-522-5/P1 identification, current-input rating, breaker configuration, wiring, and system settings. Inspect terminal connections and communication interfaces for damage or contamination. Record existing configuration parameters before replacing the module.
After installation, verify voltage and current transformer wiring, discrete inputs, relay outputs, CAN/RS-485 connections, and breaker-control logic. Confirm that the configured protection and synchronization functions match the application before returning the equipment to service. Do not alter protection thresholds or breaker-control settings without following the applicable Woodward documentation and site commissioning procedure.
Recommended Woodward Models
- Woodward 8440-2151 – LS-522-5/P1 Circuit Breaker Control Module
- Woodward 8440-2179 – LS-522-1/P1 Circuit Breaker Control Module
- Woodward 8440-2150 – LS-521-5/P1 Display Breaker Controller
- Woodward 8440-2178 – LS-521-1/P1 Display Breaker Controller
- Woodward 8440-2153 – LS-512-5/P1 Circuit Breaker Controller
- Woodward 8440-2181 – LS-512-1/P1 Circuit Breaker Controller
- Woodward 8440-2152 – LS-511-5/P1 Breaker Controller
- Woodward 8440-2180 – LS-511-1/P1 Breaker Controller
- Woodward 8440-2075 – LS-521 Marine Breaker Controller
- Woodward 8440-2074 – LS-521 Marine Breaker Controller
- Woodward 8440-2077 – LS-511 Marine Breaker Controller
- Woodward 8440-2076 – LS-511 Marine Breaker Controller
- Woodward 8440-2222 – LS-612XT-P1 Breaker Control
- Woodward 8440-2317 – LS-612XT-P2 Breaker Control
- Woodward 8928-7545 – LS-521 V2 Spare Terminal Plug Set