Description
🚀 Engineered for precise industrial engine and turbine management, the Woodward 9907-019 is a CE-approved, low-voltage, reverse-acting load sharing and speed control module within the trusted 2301A series. It delivers reliable prime mover speed regulation and proportional active power load distribution for generators operating individually or in parallel configurations, utilizing shielded cabling to ensure superior electromagnetic compliance.
Technical Specifications & Datasheet
⚙️ Dimensions: 221 mm x 155 mm x 64 mm (Standard 2301A enclosure format)
⚖️ Weight: Approx. 1.8 kg (4 lbs)
🌍 Country of Origin: United States
⚡ Power Consumption: 15 W nominal
🔌 Operating Voltage: Low-voltage DC input variant (typically 18 to 32 VDC)
🌡️ Operating Temperature: -40°C to +85°C (-40°F to +185°F)
🛡️ Enclosure Rating: IP20 chassis-mount with metallic product backplane
🔌 Certifications: CE-approved for electromagnetic compatibility and safety
⏱️ Control Action: Reverse-acting output configuration
🔄 Speed Range: Rated speed up to 11,450 Hz derived via MPU frequency input
🛡️ Wiring Requirement: Requires shielded cabling for all external control and signal lines to meet CE standards
Operating Procedures & Usage Methods
🛠️ Securely mount the module onto its metallic backplane inside a protective industrial control panel or cabinet, ensuring proper vertical clearance for terminal connections and natural convection cooling.
🔧 Connect the magnetic pickup (MPU) speed sensor, current transformers, actuator lines, and low-voltage DC power supply strictly using properly grounded shielded cables according to the terminal wiring diagram.
📋 Adjust the front-panel potentiometers (such as gain, reset, speed trim, and load droop/isochronous settings) carefully during initial calibration to match engine dynamics and synchronization parameters.
Power Sequencing Guidelines
🔌 Startup Sequence: Energize the low-voltage DC power supply to initialize internal control circuits, verify that MPU speed signals stabilize within range, and confirm zero fault codes before enabling fuel or steam delivery to the prime mover.
🛑 Shutdown Sequence: Disable the actuator control loop or cut fuel/steam supply to bring the prime mover to a complete, safe stop prior to isolating the main system power feed.
Product Usage Instructions
📖 Ensure all signal, sensor, and interconnect lines utilize continuous shielded cables with shields grounded at one end to maintain CE compliance and prevent electrical noise interference.
📖 Select isochronous mode when coordinating constant frequency across multiple paralleled engines, or switch to droop mode for single-engine speed governing and isolated electrical generation.
Frequently Asked Questions
💡 Q: What are the main electrical characteristics of the 9907-019 model? A: It is a CE-approved, low-voltage, reverse-acting load sharing and speed control unit designed for Woodward 2301A systems.
💡 Q: What does “reverse-acting” mean for this controller? A: It means an increase in the internal control signal output drives a corresponding decrease in actuator position.
💡 Q: Are there special cabling requirements for this unit? A: Yes, it requires shielded cables for external connections to comply with CE electromagnetic compatibility guidelines.
Recommended Woodward Series & Industrial Models
- Woodward 2301A Load Sharing and Speed Control 9907-018
- Woodward 2301A Load Sharing and Speed Control 9907-015
- Woodward 2301A Load Sharing and Speed Control 9905-195
- Woodward 2301A Load Sharing and Speed Control 9907-055
- Woodward 2301D Digital Load Sharing and Speed Control 9907-118
- Woodward 2301E Digital Governor 9907-1200
- Woodward MicroNet Digital Controller 5466-258
- Woodward NetCon Control System Processor 5466-500
- Woodward ProTech-GII 8237-1240 Standard Overspeed Trip Device
- Woodward Atlas Digital Control Module 5466-401