Product Description
The Woodward 5417-175 is a MicroNet High-Density Analog/Discrete Cable Assembly designed for use with compatible Woodward MicroNet control systems.
This cable provides the electrical connection between compatible MicroNet controllers and high-density analog/discrete I/O field termination equipment. It carries multiple control and monitoring signals through a dedicated cable assembly, helping organize cabinet wiring and reduce individual point-to-point connections.
The 5417-175 is identified as a 14-foot (approximately 4.27-meter) gray cable assembly with UL-related product designation. It is intended for industrial prime mover control applications, including turbine and generator control systems.
This is a connection accessory rather than an independent PLC or I/O module. Before ordering, verify the cable length, connector arrangement, and hardware compatibility against the installed MicroNet system.

Product Datasheet & Parameters
- Brand: Woodward
- Model: 5417-175
- Product Name: MicroNet High-Density Analog/Discrete Cable Assembly
- Product Series: MicroNet
- Product Type: High-Density I/O Cable
- Signal Compatibility: Analog and Discrete
- Cable Length: 14 ft (approximately 4.27 m)
- Cable Color: Gray
- Cable Configuration: High-Density
- Product Designation: UL
- System Compatibility: Compatible Woodward MicroNet high-density I/O configurations
- Connection Type: Dedicated MicroNet high-density cable connectors
- Primary Function: Analog and discrete I/O signal interconnection
- Application: Turbine, generator, and industrial prime mover control
- Power Requirements: No independent power supply required
- Place of Manufacture: Verify from the product label
- Country of Origin: Not confirmed
- Dimensions: Cable length approximately 4.27 m; connector dimensions depend on configuration
- Weight: Verify from the actual packaged item
- Product Condition: Confirm New, Surplus, or Used condition before ordering
- Discontinued Status: Listed as discontinued by some suppliers; confirm current manufacturer availability
Main Product Features
- Designed for compatible Woodward MicroNet control systems.
- Supports high-density analog and discrete signal interconnection.
- Combines multiple signal connections in one cable assembly.
- Gray cable construction for identification within control cabinets.
- 14-foot length provides flexibility in cabinet and field termination layouts.
- Helps reduce individual wiring connections and simplify cable routing.
- Intended for industrial control environments involving turbine and prime mover applications.
- Dedicated connector arrangement helps maintain the correct signal interface between compatible equipment.
Daily Maintenance and Care
- Cable Inspection
Check the full cable length for cuts, abrasion, crushing, or damaged insulation. - Connector Inspection
Inspect both connector ends for bent pins, corrosion, contamination, and damaged locking mechanisms. - Connection Security
Confirm that connectors are fully seated and secured according to the equipment installation instructions. - Signal Integrity
Monitor connected analog and discrete I/O channels for intermittent signals or unexpected status changes. - Cable Routing
Keep the cable away from sharp edges, moving equipment, hot surfaces, and sources of electrical interference. - Shielding and Grounding
Maintain the original shielding and grounding arrangement. Do not modify the cable construction without approved documentation. - Replacement Planning
Keep a compatible spare cable available where loss of I/O connectivity could affect critical equipment operation.
Troubleshooting and Common Problems
Problem: I/O Signals Are Missing
- Check both cable-end connections.
- Verify that the cable is installed in the correct ports.
- Inspect connectors for bent or damaged pins.
- Check the associated MicroNet I/O module and field termination equipment.
Problem: Intermittent Analog or Discrete Signals
- Inspect the cable for internal conductor damage.
- Check connector locking and contact condition.
- Look for excessive vibration or mechanical strain.
- Check for electrical interference and grounding problems.
Problem: Multiple I/O Channels Fail Simultaneously
- Inspect the shared high-density cable connection.
- Verify the associated I/O module power and status.
- Check the field termination assembly.
- Review controller diagnostics before replacing modules.
Problem: Cable Cannot Be Connected
- Confirm the complete part number.
- Compare connector gender, keying, and pin arrangement.
- Check whether the installed equipment requires a different cable length or configuration.
- Never force a connector into an incompatible port.
Problem: Signal Errors After Cable Replacement
- Verify the replacement cable’s pin configuration and compatibility.
- Inspect the connector seating at both ends.
- Compare the installation with the system wiring documentation.
- Perform an approved I/O functional test.
Installation and Safety Precautions
- Verify the complete part number and cable length before installation.
- Confirm compatibility with the specific MicroNet controller and I/O field termination hardware.
- Disconnect or isolate equipment as required by the system maintenance procedure.
- Do not connect or disconnect the cable while energized unless the equipment documentation specifically permits it.
- Avoid sharp bends, excessive pulling force, and tight cable ties.
- Keep the cable separated from high-voltage power wiring where required by installation standards.
- Preserve the original shielding and grounding arrangement.
- Do not splice or modify the cable unless an approved repair procedure is available.
- Verify all connected I/O channels after installation.
- Use qualified personnel for work on turbine and generator control systems.
Frequently Asked Questions
Q1: What is Woodward 5417-175?
A: It is a MicroNet high-density analog/discrete cable assembly used to interconnect compatible controller and I/O field termination equipment.
Q2: Is 5417-175 a PLC module?
A: No. It is a cable assembly and does not perform independent processing or I/O control.
Q3: What is the cable length?
A: The product documentation identifies 5417-175 as a 14-foot cable, approximately 4.27 meters long.
Q4: What signals does it support?
A: It is designed for high-density analog and discrete signal connections in compatible MicroNet configurations.
Q5: Is it compatible with every Woodward MicroNet module?
A: No. Compatibility depends on the specific controller, I/O module, field termination module, and connector arrangement.
Q6: Does the cable require an external power supply?
A: No independent power supply is required. It functions as an interconnection cable within the compatible control system.
Q7: What should be checked before purchasing?
A: Confirm the part number, 14-foot length, connector configuration, cable condition, and compatibility with the installed MicroNet hardware.
Recommended Woodward Models and Related Cable Assemblies
- 5417-171 – MicroNet high-density analog/discrete cable assembly, 6 ft.
- 5417-172 – MicroNet high-density analog/discrete cable assembly, 8 ft.
- 5417-173 – MicroNet high-density analog/discrete cable assembly, 10 ft.
- 5417-174 – MicroNet high-density analog/discrete cable assembly, 12 ft.
- 5417-176 – MicroNet high-density analog/discrete cable assembly, 16 ft.
- 5417-177 – MicroNet high-density analog/discrete cable assembly, 18 ft.
- 5417-178 – MicroNet high-density analog/discrete cable assembly, 20 ft.
- 5417-180 – MicroNet high-density analog/discrete cable assembly, 40 ft.
- 5417-179 – MicroNet NetCon transceiver cable assembly, 6 ft.
- 5417-290 – MicroNet molded DB9F-to-DB9F null modem cable.
- 5417-293 – TMR chassis/power supply interconnect cable.
- 5417-1090 – MicroNet Plus CPU/RTN fiber-optic cable, 2 m.
- 5417-1091 – MicroNet Plus CPU/RTN fiber-optic cable, 3 m.
- 5417-1092 – MicroNet Plus CPU/RTN fiber-optic cable, 5 m.
- 5417-1093 – MicroNet Plus CPU/RTN fiber-optic cable, 10 m.
Note: Related cable models have different lengths, connector types, and functions. They are not automatically interchangeable. Verify the exact system connection requirements before ordering.