Description
Product Description
The Emerson EPRO CON021 is an eddy current signal converter designed for machinery condition monitoring and protection applications. It interfaces with compatible PR642x eddy current displacement sensors and converts probe signals into proportional voltage outputs for monitoring and control equipment.
The CON021 is designed for panel mounting inside an industrial enclosure. It is used in critical rotating machinery applications, including steam turbines, gas turbines, hydro turbines, compressors, pumps, and fans.
The converter supports measurements of radial and axial shaft displacement, shaft position, eccentricity, and speed-related signals. Its high-frequency response makes it suitable for machinery monitoring applications where accurate dynamic displacement information is required.
The unit uses a self-locking LEMO connector for the transducer and screw terminals for power and output connections. Its compact housing allows installation near the monitoring cabinet while keeping the sensor signal interface separate from the main monitoring system.
For replacement projects, verify the exact sensor model, measuring range, output voltage configuration, and power supply before installation.

CON021
Key Technical Specifications
- Brand: Emerson / EPRO
- Model: CON021
- Product Name: Eddy Current Signal Converter
- Product Type: Sensor Signal Conditioning Module
- Application: Machinery Health Monitoring and Protection
- Sensor Technology: Eddy Current Displacement Measurement
- Compatible Sensor Families: PR6422, PR6423, PR6424, PR6425, PR6426, PR6453
- Frequency Response: 0–20 kHz (-3 dB)
- Rise Time: Less than 15 μs
- Reference Voltage: -12 V DC
- Output Range: -4 to -20 V DC or -2 to -18 V DC, depending on supply configuration
- Supply Voltage: -23 to -32 V DC for the -4 to -20 V output range
- Alternative Supply Range: -21 to -32 V DC for the -2 to -18 V output range
- Sensor Connector: Self-locking LEMO socket
- Power and Output Connections: Screw terminals
- Maximum Terminal Wire Size: 1.5 mm²
- Operating Temperature: -30 to +100°C
- Shock and Vibration: 5 g at 60 Hz and 25°C
- Protection Class: IP20
- Housing Material: LMgSi 0.5 F22 aluminum alloy
- Mounting: Four M5 × 20 mounting screws
- Dimensions: Approximately 56 × 72 × 41 mm
- Weight: Approximately 120 g
- Installation: Panel-mounted, inside a suitable enclosure
- Country of Origin: Verify from the product label
- Product Status: Legacy machinery-monitoring spare; confirm current availability
Key Features
- High-frequency eddy current signal conversion up to 20 kHz.
- Compatible with multiple Emerson PR642x sensor families.
- Supports shaft displacement and position measurement applications.
- Self-locking LEMO transducer connection.
- Screw-terminal connections for power and voltage output.
- Configurable output range according to supply voltage.
- Compact aluminum housing for panel installation.
- Designed for continuous machinery monitoring applications.
- Suitable for integration with compatible Emerson machinery protection systems.
Application Scenarios and Pain Points
Steam turbines: Monitors shaft vibration, axial displacement, and eccentricity to help identify abnormal rotor movement and potential mechanical problems.
Gas turbines: Provides displacement signals for machinery protection systems monitoring critical rotating components.
Hydro turbines: Supports shaft-position and displacement monitoring in large rotating equipment.
Industrial compressors: Helps monitor radial and axial shaft movement to identify abnormal operating conditions.
Pumps and fans: Provides non-contact displacement measurement for rotating machinery condition monitoring.
Power generation facilities: Interfaces eddy current probes with compatible monitoring systems for continuous machinery-health assessment.
Maintenance and replacement: Provides a replacement signal-conversion component for existing installations using compatible PR642x sensor chains.
Installation and Commissioning
- Isolate the relevant electrical supply and follow the site’s lockout procedure.
- Record the original converter model and complete ordering designation.
- Confirm the connected probe model and extension-cable configuration.
- Verify the required measurement range and converter output option.
- Mount the CON021 securely using the specified mounting arrangement.
- Connect the probe through the self-locking LEMO connector.
- Connect the negative DC supply, ground, and signal output according to the wiring diagram.
- Verify the supply voltage and output range before energizing.
- Check probe gap voltage and sensor condition.
- Compare the converter output with the expected sensor calibration curve.
- Verify the connected monitoring channel’s measurement scaling and alarm settings.
- Perform a controlled functional test and record the results.
Important: The standard CON021 and extended-range variants are not automatically interchangeable. PR6425 sensors require an extended-range converter. Confirm the complete probe and converter combination before ordering.
Daily Maintenance
- Monitor shaft displacement and vibration readings through the connected monitoring system.
- Check for abnormal signal fluctuations or unexpected zero-point changes.
- Inspect LEMO connectors for secure engagement and contamination.
- Check screw terminals for looseness during scheduled maintenance.
- Monitor DC supply voltage and signal output.
- Inspect the converter housing for corrosion, moisture, or physical damage.
- Maintain suitable cabinet ventilation and environmental conditions.
- Review sensor cable condition and shielding.
- Keep records of converter replacement and probe calibration.
Troubleshooting and FAQ
Q1: What is the Emerson CON021?
It is an eddy current signal converter that interfaces compatible PR642x sensors with machinery monitoring equipment.
Q2: Which sensors are compatible with the CON021?
The documented sensor families include PR6422, PR6423, PR6424, PR6425, PR6426, and PR6453. Specific measuring ranges may require extended-range converter versions.
Q3: What is the output signal of the CON021?
Depending on the supply configuration, the converter provides either -4 to -20 V DC or -2 to -18 V DC.
Q4: Does the CON021 provide a 4–20 mA output?
No. Its documented output is a proportional voltage signal. A compatible monitoring input is required to process that signal.
Q5: What is the difference between CON021 and CON011?
The CON021 is designed for panel mounting inside an enclosure, while the CON011 is intended for field mounting near the monitored machinery and has a different protection arrangement.
Q6: Can the CON021 replace CON031?
Both are panel-mounted eddy current signal converters, but their sensor connection arrangements differ. CON021 uses a self-locking LEMO connector, whereas CON031 uses screw-terminal sensor connections. Verify the complete sensor and wiring configuration before substitution.
Q7: What causes an unstable converter output?
Possible causes include incorrect probe gap, damaged sensor cables, loose LEMO connections, incorrect supply voltage, incompatible probe and converter combinations, or electromagnetic interference.
Q8: Can the standard CON021 be used with PR6425?
PR6425 requires an extended-range converter configuration. The appropriate CON021/915-xxx variant must be selected according to the required measuring range.
Safety Precautions
- Installation must be performed by qualified instrumentation personnel.
- Isolate the converter power supply before wiring or servicing.
- Verify negative DC supply polarity and grounding.
- Do not connect incompatible probes or extension cables.
- Confirm output voltage compatibility with the monitoring equipment.
- Avoid exceeding the specified terminal wire capacity.
- Install the IP20 converter inside a suitable protected enclosure.
- Do not change machinery protection alarm settings without engineering authorization.
- Test the complete sensor and monitoring channel before returning equipment to service.
Recommended Related Emerson Models and Components
The following components are related to the Emerson EPRO eddy current measurement and machinery-monitoring system. They are not all direct replacements for CON021.
- Emerson CON011 – Field-Mounted Eddy Current Signal Converter
- Emerson CON031 – Panel-Mounted Eddy Current Signal Converter
- Emerson CON041 – Eddy Current Signal Converter
- Emerson PR6422 – Eddy Current Displacement Sensor
- Emerson PR6423 – Eddy Current Displacement Sensor
- Emerson PR6424 – Eddy Current Displacement Sensor
- Emerson PR6425 – Eddy Current Displacement Sensor
- Emerson PR6426 – Eddy Current Displacement Sensor
- Emerson PR6453 – Eddy Current Displacement Sensor
- Emerson PR6422/Series – Probe Assembly
- Emerson PR6423/Series – Probe Assembly
- Emerson PR6424/Series – Probe Assembly
- Emerson A6110 – Shaft Relative Vibration Monitor
- Emerson A6210 – Thrust and Differential Expansion Monitor
- Emerson A6312 – Dual-Channel Speed and Key Monitor
Always verify sensor sensitivity, measuring range, extension-cable length, and converter ordering suffix before selecting a replacement.
Inspection and Quality Control
- Part identification: Confirm the CON021 model and product label.
- Visual inspection: Check the housing, mounting points, LEMO connector, and screw terminals.
- Connector inspection: Verify that the sensor connector locks correctly and has no damaged contacts.
- Electrical inspection: Check the supply and output terminals against the approved wiring diagram.
- Signal testing: Verify output voltage using a compatible sensor and calibrated test equipment.
- Frequency response: Confirm signal response using an appropriate test arrangement where required.
- Environmental inspection: Check for corrosion, moisture ingress, and mechanical damage.
- Final documentation: Record serial or batch information, inspection photographs, and functional test results.
The actual condition, sensor compatibility, output configuration, and test status should be confirmed for each individual unit before shipment.