Sale!

Honeywell | CC-IP0101 | PROFIBUS DP Gateway Module

Original price was: $10,000.00.Current price is: $666.00.

Product NO:CC-IP0101

Brand:Honeywell

Delivery time: In stock

Product status: Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

Product Description

The Honeywell CC-IP0101 (51410056-175) is a PROFIBUS DP Gateway Module used in Honeywell Experion PKS Series C control-system applications. It provides a communication interface between the Honeywell controller environment and PROFIBUS DP field devices, allowing supported third-party equipment to exchange process data with the distributed control system.

The module is identified in supplier documentation as a PROFIBUS Gateway Module with two DP network segments. It is intended for applications requiring integration of PROFIBUS-compatible instruments, motor controllers, remote I/O stations, and other industrial automation equipment.

The CC-IP0101 is associated with Honeywell C300 controller installations and Series C hardware. Correct integration depends on the controller configuration, supported firmware, IOTA assembly, network topology, and PROFIBUS device configuration.

The complete part number, 51410056-175, should be checked before ordering. Do not confuse the CC-IP0101 with the similarly named 8C-IP0101, which belongs to a different Honeywell product family.

CC-IP0101

CC-IP0101

Product Datasheet

Parameter Specification
Brand Honeywell
Model CC-IP0101
Part Number 51410056-175
Product Series Experion PKS / Series C
Product Type PROFIBUS DP Gateway Module
Functional Role PROFIBUS Gateway / Fieldbus Interface
Supported Network PROFIBUS DP
DP Network Segments 2, according to supplier product documentation
PROFIBUS Role DP Gateway; master functionality reported
Maximum Supported Devices Up to 127 devices reported; verify per-segment limits in the applicable documentation
Communication Speed 9.6 kbps to 12 Mbps, supplier-listed
Compatible Controller Family Honeywell C300; confirm exact controller and firmware
Associated Hardware Series C IOTA assembly
System Integration Honeywell Experion PKS
Power Supply System/IOTA power arrangement; verify electrical requirements
Communication Configuration PROFIBUS network and device configuration
Mounting Series C hardware assembly
Dimensions Confirm from the original product documentation
Weight Approximately 0.25 kg, supplier-listed; verify actual unit
Country of Origin Supplier listings report USA; confirm from product label
Product Status Legacy system spare; confirm lifecycle status
Condition Confirm actual supplied unit

 

Technical Features & Specifications

1. PROFIBUS DP Communication

The CC-IP0101 provides a gateway interface for integrating PROFIBUS DP field devices with Honeywell control-system architecture. It supports communication between the control system and compatible field-level equipment.

Typical connected devices may include remote I/O stations, motor control equipment, intelligent instruments, and other PROFIBUS DP-compatible devices. Actual device compatibility depends on the supported communication profile and configuration.

2. Dual DP Network Segments

Supplier documentation identifies the CC-IP0101 as a gateway supporting two PROFIBUS DP segments. This arrangement can help organize field devices into separate network sections and simplify system integration.

The two segments should be designed according to the applicable network architecture, cable requirements, termination rules, and device addressing limits.

3. Communication Speed

The published supplier specification lists PROFIBUS DP communication speeds from 9.6 kbps to 12 Mbps. The actual operating speed must be supported by all devices on the relevant segment and selected during network configuration.

4. Experion PKS Integration

The module is intended for Honeywell Experion PKS environments, particularly installations using the C300 controller family. Integration requires compatible controller hardware, supported firmware, correct IOTA installation, and appropriate control-system configuration.

Before replacement, verify the existing module’s part number and the applicable Series C system documentation.

5. Field Device Integration

The gateway supports the exchange of configured process data between the control system and PROFIBUS DP devices. During engineering, the system integrator should verify device addresses, GSD files, cyclic data mapping, diagnostic handling, and communication status.

6. Maintenance and Replacement

The CC-IP0101 is a system-specific communication component. A replacement should match the original hardware identification and system configuration. Replacing it with a different Honeywell communication module based only on a similar model name may cause hardware or configuration incompatibility.

 

Application Scenarios & Pain Points

  • Oil and gas facilities: Integrates compatible PROFIBUS DP field equipment into Honeywell Experion PKS control systems.
  • Chemical processing plants: Connects supported field devices and intelligent equipment to centralized process control.
  • Power generation: Supports fieldbus communication for compatible auxiliary equipment and monitoring devices.
  • Water treatment: Integrates PROFIBUS-compatible instruments and remote equipment into the control architecture.
  • Industrial manufacturing: Facilitates data exchange between the DCS and compatible motor control or remote I/O equipment.
  • Legacy DCS maintenance: Provides a replacement option for existing Honeywell Series C installations using the CC-IP0101 gateway.

 

First-Time Installation Checklist

  1. Confirm the complete model number CC-IP0101 and part number 51410056-175.
  2. Compare the replacement unit’s label, hardware revision, and connector arrangement with the installed module.
  3. Verify the compatible Series C hardware and IOTA assembly.
  4. Confirm controller model and firmware compatibility.
  5. Record the existing PROFIBUS network configuration before removing the original module.
  6. Back up device addresses, GSD files, network parameters, and process-data mappings.
  7. Inspect PROFIBUS connectors, cable shielding, grounding, and network termination.
  8. Confirm the two DP segments are wired according to the approved network design.
  9. Verify that all field devices use supported communication speeds and unique addresses.
  10. Check module power and status indications after installation.
  11. Verify communication with each configured PROFIBUS device.
  12. Confirm process-data mapping and diagnostic reporting before returning the system to normal operation.

 

Daily Maintenance

  • Monitor module status and PROFIBUS communication diagnostics.
  • Check for recurring bus faults, device timeouts, or communication interruptions.
  • Inspect fieldbus connectors and cable shielding during scheduled maintenance.
  • Verify that network termination is installed correctly at the required segment endpoints.
  • Review device address conflicts and configuration changes.
  • Maintain backups of GSD files and network configuration records.
  • Check the Series C assembly for contamination, loose connections, or signs of overheating.
  • Record hardware revisions and replacement history for maintenance traceability.

 

Troubleshooting & Frequently Asked Questions

Q1: What is the main function of the Honeywell CC-IP0101?

A: It is a PROFIBUS DP Gateway Module used to connect compatible PROFIBUS field devices with Honeywell Experion PKS control-system applications.

Q2: What is the part number for CC-IP0101?

A: The commonly listed order number is 51410056-175. Always compare the complete number with the label on the existing module.

Q3: How many PROFIBUS segments does the module support?

A: Supplier documentation identifies two DP network segments. Confirm the exact segment configuration and device limits against the applicable Honeywell documentation.

Q4: What communication speed does the module support?

A: Supplier specifications list speeds from 9.6 kbps to 12 Mbps. The selected speed must be compatible with all devices on the network.

Q5: Is the CC-IP0101 compatible with the Honeywell C300 controller?

A: It is listed for Honeywell C300 and Experion PKS applications. Confirm the controller revision, firmware, IOTA assembly, and system configuration before installation.

Q6: Can the CC-IP0101 replace the 8C-IP0101?

A: No direct interchangeability should be assumed. The 8C-IP0101 belongs to a different Honeywell hardware family. Check the system architecture, mounting arrangement, and manufacturer compatibility documentation.

Q7: What should be checked if PROFIBUS communication fails?

A: Check module status, power, cable continuity, connector condition, bus termination, device addresses, communication speed, and GSD configuration. Review the controller and gateway diagnostics to identify the affected segment or device.

Q8: Does the replacement module require configuration?

A: Yes, the PROFIBUS network and device configuration must be checked. Restore the approved configuration and verify data mapping and device communication before returning the process to service.

 

Safety Precautions

  • Installation and replacement must be performed by qualified industrial automation personnel.
  • Follow Honeywell procedures for module removal and installation.
  • Observe the approved system isolation and shutdown requirements.
  • Use ESD protection when handling electronic modules.
  • Do not disconnect fieldbus wiring without considering the effect on operating devices and process control.
  • Verify power and IOTA compatibility before installation.
  • Use approved PROFIBUS cable, connectors, shielding, and termination components.
  • Confirm all device addresses and network settings before commissioning.
  • Do not assume that similar Honeywell model numbers have interchangeable hardware or firmware.
  • Follow the applicable Honeywell Experion PKS and Series C documentation.

 

Recommended Related Models & Components

The following Honeywell products are related to Experion PKS, Series C, and PROFIBUS gateway applications. They are useful references for system maintenance and spare-parts planning, but are not all direct replacements for CC-IP0101.

  1. CC-PCNT02 – Series C controller module
  2. CC-PCF901 – Series C controller-related module
  3. CC-TP0X01 – Series C IOTA assembly reference; verify exact suffix
  4. CC-PDIL01 – Digital input module
  5. CC-PDOB01 – Digital output module
  6. CC-PAIH51 – Analog input module
  7. CC-PAIN01 – Analog input module
  8. CC-PAIX01 – Analog input module
  9. CC-PAOX01 – Analog output module
  10. CC-TAIX01 – Analog input termination assembly
  11. CC-TAIX11 – Redundant analog input termination assembly
  12. CC-TAIN01 – Analog input termination assembly
  13. CC-TAIN11 – Redundant analog input termination assembly
  14. 8C-IP0101 – Series 8 PROFIBUS gateway module; different product family
  15. 8C-IP0102 – Series 8 PROFIBUS gateway module; different product family

Verify each complete order number, hardware revision, IOTA requirement, and controller compatibility before purchasing.

about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.