Product Description

The GE IS200TVIBH2BBB is a TVIB Vibration Input Terminal Board designed for GE Speedtronic Mark VI turbine control systems. It provides the field wiring and signal interface between vibration sensors and the associated VVIB vibration monitoring board.

The TVIB board supports machinery condition-monitoring applications involving shaft vibration, shaft displacement, and rotational reference signals. It interfaces with compatible Bently Nevada proximity probes and other supported vibration sensors, routing measurement signals to the VVIB board for processing and monitoring.

The H2B hardware configuration includes BNC connections for portable vibration data collection equipment, allowing maintenance personnel to access buffered vibration signals during predictive-maintenance activities. The assembly also uses field terminal blocks and dedicated board connectors for sensor wiring and system integration.

The IS200TVIBH2BBB is a terminal and interface board, not a standalone vibration processor. Correct operation depends on the associated VVIB board, sensor configuration, cabling, and Mark VI system architecture.

IS200TVIBH2BBB

IS200TVIBH2BBB

Key Technical Specifications

  • Brand: GE (General Electric)
  • Product Series: Speedtronic Mark VI
  • Model: IS200TVIBH2BBB
  • Functional Acronym: TVIB
  • Product Type: Vibration Input Terminal Board
  • Primary Function: Vibration sensor termination and signal interfacing
  • Associated Monitoring Board: VVIB
  • Measurement Applications: Shaft vibration, shaft displacement, and Keyphasor reference signals
  • Sensor Compatibility: Supported Bently Nevada proximity probes and compatible seismic or acceleration sensors, subject to system configuration
  • Input Architecture: Sensor signals routed to the VVIB monitoring board
  • Field Connections: Two large screw-terminal blocks
  • Board Connectors: Multiple plug connectors for sensor and monitoring-board interfaces
  • Buffered Signal Access: BNC connections for portable vibration measurement equipment on the H2A/H2B-type configuration
  • Sensor Excitation: Supplied through the associated vibration-monitoring architecture; verify exact voltage and wiring against the manual
  • System Configuration: Simplex or TMR, subject to the associated VVIB arrangement
  • Mounting: Panel-mounted control-system terminal board
  • Calibration: No board-level potentiometer adjustment; verify system configuration and sensor calibration separately
  • Dimensions: Verify against the exact board revision
  • Weight: Approximately 0.8 lb (0.36 kg), according to distributor listing
  • Product Status: Discontinued by manufacturer according to distributor lifecycle information
  • Country of Origin: Verify against the product nameplate

 

Key Features

  • Vibration signal termination: Provides a field connection point for supported turbine vibration sensors.
  • VVIB integration: Transfers sensor signals to the associated GE vibration monitoring board.
  • Multiple sensor applications: Supports configured vibration, displacement, and rotational reference measurement circuits.
  • BNC signal access: Facilitates connection of portable vibration data collection equipment.
  • Field wiring organization: Uses screw-terminal connections for structured sensor wiring.
  • TMR system support: Can be used in supported simplex and triple-modular-redundant configurations.
  • Maintenance accessibility: Allows technicians to inspect field connections and access measurement signals without treating the terminal board as a standalone processor.

 

Application Scenarios and Pain Points

Gas turbine vibration monitoring: Provides the sensor termination interface for monitoring shaft movement and vibration conditions.

Steam turbine protection: Supports vibration and displacement measurement circuits used in turbine condition monitoring.

Generator monitoring: Interfaces compatible vibration sensors with the turbine control and monitoring architecture.

Compressor machinery: Supports vibration measurement arrangements for rotating equipment where the GE Mark VI system is configured for the application.

Predictive maintenance: BNC signal access supports portable measurement equipment used for vibration analysis and maintenance investigations.

 

Installation and Commissioning

  1. Verify the complete part number IS200TVIBH2BBB and inspect the board revision and connector arrangement.
  2. Confirm that the target Mark VI system uses a compatible VVIB monitoring board.
  3. Check the system drawings for simplex or TMR wiring configuration.
  4. Verify sensor type, probe gap requirements, cable length, and connector compatibility.
  5. Install the terminal board in the designated panel location.
  6. Connect field sensor wiring to the correct terminal positions.
  7. Connect the designated cables between the TVIB and VVIB boards.
  8. Confirm sensor excitation, polarity, shielding, and grounding arrangements against the GE wiring documentation.
  9. Verify the configured sensor channels and monitoring parameters.
  10. Check buffered signals through the designated BNC connections using approved test equipment.
  11. Perform functional vibration-channel testing and confirm that the controller receives valid measurements.
  12. Verify alarm and trip logic through the approved turbine commissioning procedure.

Do not substitute a TVIB board based only on a similar model number. Confirm the VVIB interface, redundancy arrangement, board revision, and wiring configuration.

 

Daily Maintenance

  • Inspect terminal blocks for loose connections and damaged conductors.
  • Check board connectors and ribbon cables for secure seating.
  • Inspect sensor cables for abrasion, moisture, and electromagnetic interference.
  • Monitor vibration-channel quality and investigate abnormal signal fluctuations.
  • Check sensor excitation and probe gap measurements according to the maintenance procedure.
  • Inspect BNC connectors for physical damage and contamination.
  • Review vibration alarms and historical trends for unusual changes.
  • Keep cabinet temperature and environmental conditions within system requirements.
  • Maintain updated sensor-channel assignments and wiring documentation.

 

Troubleshooting and FAQ

Q1: What is the main function of the IS200TVIBH2BBB?

It provides the field termination and signal interface for vibration sensors connected to a compatible GE VVIB monitoring board.

Q2: Is the TVIB a vibration processor?

No. The TVIB is the terminal board. The associated VVIB board performs the vibration monitoring and signal-processing functions.

Q3: Which sensors can be connected?

The board is used with supported proximity probes and compatible vibration sensors, including applicable Bently Nevada measurement devices. Confirm the sensor type and wiring against the system manual.

Q4: What is the purpose of the BNC connectors?

They provide access to buffered vibration signals for portable vibration data collection and diagnostic equipment.

Q5: Can the IS200TVIBH2BBB be used in a TMR system?

The TVIB architecture supports simplex and TMR arrangements when configured with the appropriate VVIB boards and cabling. Confirm the exact arrangement against the GE system drawings.

Q6: Does the board require calibration?

The TVIB board does not use board-level potentiometers for calibration. Sensor setup, probe gap, channel configuration, and monitoring parameters must still be verified.

Q7: What should be checked if a vibration channel has no signal?

Check sensor power, probe wiring, cable continuity, terminal connections, TVIB-to-VVIB cabling, and the corresponding VVIB channel diagnostics.

Q8: Is this board compatible with Mark VIe I/O packs?

Do not assume compatibility with Mark VIe I/O packs. The TVIB is associated with the VVIB vibration-monitoring architecture. Confirm the exact host-system design before ordering.

 

Safety Precautions

  • Follow approved turbine shutdown and electrical isolation procedures before installation.
  • Do not disconnect or modify vibration sensor wiring while the system is operating unless explicitly permitted by the maintenance procedure.
  • Verify sensor excitation voltage and polarity before connection.
  • Use appropriate shielded cables and grounding practices.
  • Avoid routing vibration sensor cables alongside high-power switching conductors.
  • Do not bypass vibration alarm or trip functions during normal operation.
  • Test protection channels and trip logic only under authorized commissioning procedures.
  • Confirm TMR channel assignments and redundancy configuration before replacing the board.

 

Recommended Related Models and Components

The following are related GE turbine vibration monitoring and Mark VI components. They are not all direct replacements for IS200TVIBH2BBB.

  1. GE VVIB – Vibration Monitoring Board
  2. GE IS200TVIBH2B – TVIB Vibration Input Terminal Board
  3. GE IS200TVIBH2BAA – TVIB Vibration Terminal Board Variant
  4. GE IS200TVBAH1A – Vibration Terminal Board
  5. GE Bently Nevada 3300 XL 8 mm Proximity Probe
  6. GE Bently Nevada 3300 XL Extension Cable
  7. GE Bently Nevada 3300 XL Proximitor Sensor
  8. GE Bently Nevada 3300 NSv Proximity Probe
  9. GE Bently Nevada 3300 Series Seismic Sensor
  10. GE Bently Nevada Velomitor Piezo-Velocity Sensor
  11. GE IS200TBAIH1C – Mark VI Analog I/O Terminal Board
  12. GE IS200TBCIH1B – Mark VI Contact Input Terminal Board
  13. GE IS200TRTDH1B – Mark VI RTD Terminal Board
  14. GE IS200TTURH1B – Mark VI Turbine Terminal Board
  15. GE IS200VCMIH1B – Mark VI VME Communication Interface

 

Inspection and Quality Control

Verify the GE identification label, complete part number, and hardware revision. Inspect the PCB, terminal blocks, plug connectors, BNC connectors, and mounting points for physical damage, corrosion, or contamination.

Where a compatible Mark VI test environment is available, check connector integrity, field wiring continuity, sensor excitation, and signal transfer to the associated VVIB board. Verify representative vibration channels using an approved sensor simulator or test instrument.

Record the serial number, board revision, physical condition, inspection results, and test configuration. Confirm compatibility with the existing VVIB hardware and system redundancy arrangement before installation.

about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.