Sale!

GE | IS200TPROH1BBB | Mark VI Protection Terminal Board

Original price was: $10,000.00.Current price is: $666.00.

Product NO:IS200TPROH1BBB

Brand:GE

Delivery time: In stock

Product status: Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

Product Description

The GE IS200TPROH1BBB is a Protection Terminal Board (TPRO) designed for the GE Mark VI Speedtronic turbine control system. It provides the termination and signal-interface functions required by the turbine protection architecture, routing critical protection-related signals to the associated VPRO protection processor.

The board is used in turbine protection applications involving speed monitoring, generator and bus voltage signals, and temperature-related inputs. These signals support protective functions such as emergency overspeed detection and backup generator protection.

The IS200TPROH1BBB is a protection-system interface board rather than a standalone controller or general-purpose I/O module. Its correct operation depends on the associated VPRO hardware, cable connections, terminal wiring, and installed protection configuration.

For replacement projects, the complete part number and BBB hardware revision must be checked against the original board. Similar-looking TPRO boards and other Mark VI protection terminal assemblies should not be assumed interchangeable.

IS200TPROH1BBB

IS200TPROH1BBB

Product Datasheet

  • Brand: General Electric (GE)
  • Model: IS200TPROH1BBB
  • Product Name: Mark VI Protection Terminal Board
  • Board Designation: TPRO
  • Product Type: Turbine Protection Terminal Board
  • Product Family: GE Speedtronic Mark VI
  • Application: Turbine protection and emergency protection signal interfacing
  • Associated Protection Processor: VPRO family; verify exact system configuration
  • Signal Categories: Speed, temperature, generator voltage, bus voltage, and protection-related signals
  • Hardware Revision: BBB
  • Mounting: Mark VI control cabinet installation
  • Field Connections: Terminal blocks and associated board connectors
  • Dimensions: Supplier references vary; verify against the physical assembly
  • Weight: Approximately 0.8 kg in some supplier listings; not an OEM-confirmed value
  • Power Requirements: Confirm from the applicable GE hardware documentation and system drawings
  • Country of Origin: Supplier listings commonly identify the United States; verify the product label
  • Product Status: Not independently verified

 

Technical Features & Specifications

  • Protection Signal Interface: Provides termination and routing for selected turbine protection signals.
  • Speed Signal Support: Associated with speed signal inputs used by the VPRO protection architecture, including emergency overspeed protection.
  • Temperature Signal Interface: Supports temperature-related protection inputs as defined by the installed system configuration.
  • Generator and Bus Voltage Signals: Provides interfaces for voltage signals used in generator and synchronization-related protection functions.
  • Protection Architecture: Designed for use within the GE Mark VI turbine protection system.
  • VPRO Integration: Works with the associated protection processor and its configured signal paths. Verify the exact processor and cable arrangement before replacement.
  • Terminal Connections: Field wiring must follow the original terminal assignment and approved GE wiring drawings.
  • Hardware Revision Control: The complete IS200TPROH1BBB designation is important when checking replacement compatibility.

 

Application Scenarios & Pain Points

  • Gas Turbine Protection: Provides signal termination for protection functions associated with turbine speed and operating conditions.
  • Steam Turbine Protection: Supports protection-related signal interfacing within compatible Mark VI installations.
  • Emergency Overspeed Protection: Supplies relevant speed information to the associated protection processor.
  • Generator Protection: Supports signal paths involving generator and bus voltage measurements.
  • Power Plant Maintenance: Used when replacing damaged or faulty protection terminal assemblies during turbine control system maintenance.
  • Turbine Control System Upgrades: Provides an interface reference when evaluating existing Mark VI protection hardware and its associated wiring.

 

First-Time Installation Checklist

  1. Confirm the complete part number IS200TPROH1BBB from the original nameplate.
  2. Check the PCB revision and compare it with the removed assembly.
  3. Inspect terminal blocks, board connectors, components, and solder joints for physical damage.
  4. Confirm compatibility with the installed Mark VI protection architecture and associated VPRO processor.
  5. Photograph and label all existing wiring and cable connections before removal.
  6. Verify connector orientation and cable identification against the original drawings.
  7. Confirm speed, temperature, generator voltage, and bus voltage signal assignments.
  8. Check grounding, shielding, and signal-routing requirements.
  9. Inspect the associated protection processor and connected cables for diagnostic faults.
  10. Perform the prescribed protection-system checks and signal validation before returning the turbine to service.

 

Daily Maintenance

  • Review turbine protection diagnostics and active alarms.
  • Monitor speed-related protection signals for abnormal readings.
  • Check generator and bus voltage signal indications against expected operating conditions.
  • Inspect terminal connections for looseness, discoloration, or corrosion.
  • Check board connectors and cable harnesses for mechanical damage.
  • Keep the control cabinet clean and within the specified environmental limits.
  • Record protection-system alarms and unexplained signal fluctuations.
  • Maintain accurate records of board revisions, wiring changes, and maintenance activities.

 

Troubleshooting & Frequently Asked Questions

Q1: What is the GE IS200TPROH1BBB?

It is a GE Mark VI TPRO protection terminal board used to interface turbine protection signals with the associated protection processor.

Q2: Is the IS200TPROH1BBB a CPU or general-purpose I/O module?

No. It is a protection terminal board. Its role is signal interfacing and termination within the turbine protection architecture.

Q3: Which protection signals are associated with this board?

Supplier technical descriptions associate it with speed, temperature, generator voltage, and bus voltage signals. The exact channel assignments should be confirmed using the applicable GE wiring documentation.

Q4: Is it compatible with the VPRO protection processor?

Supplier references identify the board as part of the VPRO protection signal architecture. Confirm the exact processor model, cable arrangement, and Mark VI configuration before installation.

Q5: Can IS200TPROH1BBB replace another TPRO revision?

Not automatically. Hardware revisions may have different circuit configurations or connector arrangements. Verify interchangeability through GE documentation before ordering or installing a substitute.

Q6: Can this board be used in a Mark V system?

Do not assume compatibility. The IS200TPROH1BBB is identified with the Mark VI family, while Mark V uses a different board architecture.

Q7: What should be checked if a protection signal is abnormal?

Check the field transmitter or sensor, terminal wiring, cable connections, signal conditioning, associated VPRO diagnostics, and the relevant protection configuration.

Q8: Can the board be replaced while the turbine is running?

Do not assume that online replacement is permitted. Follow the plant’s approved turbine protection maintenance and isolation procedures.

 

Safety Precautions

  • Treat the board as part of the turbine protection system.
  • Follow approved lockout/tagout and turbine maintenance procedures.
  • Do not disconnect protection wiring without understanding the associated trip and alarm consequences.
  • Verify the exact terminal assignments before connecting field signals.
  • Avoid applying unverified power or test voltages to board terminals.
  • Use appropriate ESD protection when handling the PCB.
  • Do not substitute different TPRO revisions without documented compatibility confirmation.
  • Perform required protection-function validation before returning equipment to operation.
  • Any changes to emergency overspeed or generator protection circuits must be reviewed and approved by qualified turbine protection personnel.

 

Recommended Related Models & Components

The following GE components are associated with Mark VI turbine control and protection systems. They are related products, not automatic substitutes for the IS200TPROH1BBB.

  1. GE VPRO – Mark VI Protection Processor
  2. GE IS215VPROH2B – VPRO Protection Processor Board
  3. GE IS215VPROH1B – VPRO Protection Processor Variant
  4. GE IS200TREGH1B – Turbine Emergency Trip Terminal Board
  5. GE IS200TRPGH1B – Trip Relay Protection Terminal Board
  6. GE IS200TRPLH1B – Trip Relay Terminal Board
  7. GE IS200TRPSH1B – Trip Relay Terminal Board Variant
  8. GE IS200TBAIH1C – Analog Input Terminal Board
  9. GE IS200TBCIS2C – Contact Input Terminal Board
  10. GE IS200TVIBH2B – Vibration Input Terminal Board
  11. GE IS200TBTCH1C – Thermocouple Input Terminal Board
  12. GE IS200TSVCH1C – Servo Terminal Board
  13. GE IS200TDBTH6A – Discrete Terminal Board
  14. GE IS200TRLYH1B – Relay Terminal Board
  15. GE IS220PPROH1A – Mark VIe Protection I/O Pack; different system generation and not a direct replacement
about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.