Description
Product Description
The Emerson EPRO PR6423/00R-010 with CON021 is an eddy-current proximity measurement system designed for non-contact monitoring of rotating machinery. The assembly consists of an 8 mm reverse-mount displacement probe and a CON021 signal converter. It measures radial and axial shaft displacement, vibration, position, eccentricity, and related dynamic shaft behavior in steam turbines, gas turbines, hydro turbines, compressors, pumps, and other critical rotating equipment. The PR6423 probe operates with a nominal linear measuring range of 2 mm and a sensitivity of 8 V/mm when used with the specified target material and converter configuration. The CON021 converts the probe signal into a proportional voltage output for connection to compatible machinery monitoring equipment. Its frequency response extends from DC to 20 kHz (-3 dB), supporting both static gap measurement and dynamic shaft movement analysis. The reverse-mount construction is intended for installations where the probe is mounted from the rear of the measurement position. Before installation, verify the mounting geometry, probe thread, cable length, target material, converter configuration, and monitoring-system input requirements.

EMERSON PR642300R-010+CON021
Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Emerson / EPRO |
| Probe Model | PR6423/00R-010 |
| Converter Model | CON021 |
| Product Series | EPRO Eddy Current Measurement System |
| Product Name | 8 mm Eddy Current Proximity Measurement System |
| Product Type | Non-Contact Displacement Sensor and Signal Converter |
| Measurement Principle | Eddy-current proximity measurement |
| Probe Tip Diameter | 8 mm |
| Probe Mounting Style | Reverse Mount |
| Case Thread | M10 × 1; verify exact probe label |
| Linear Measuring Range | 2 mm (80 mils) |
| Initial Air Gap | 0.5 mm (20 mils) |
| Sensitivity | 8 V/mm (203.2 mV/mil), ±5% at 0 to +45 °C |
| Linearity Deviation | ±0.025 mm (±1 mil) at 0 to +45 °C |
| Minimum Shaft Diameter | 25 mm |
| Target Material | Ferromagnetic steel, standard reference 42CrMo4 / AISI 4140 |
| Frequency Response | 0–20,000 Hz (-3 dB) |
| Converter Rise Time | Less than 15 µs |
| Converter Supply Voltage | -23 to -32 V DC or -21 to -32 V DC, depending on output configuration |
| Converter Output | Proportional voltage output; configuration-dependent range |
| Converter Protection | IP20 |
| Probe Protection | IP66 |
| Probe Temperature Range | -35 to +200 °C |
| Probe Cable and Connector Temperature | -35 to +150 °C |
| Converter Temperature Range | -30 to +100 °C |
| Probe Weight | Approx. 100 g with 1 m cable |
| Converter Weight | Approx. 120 g |
| Country of Origin | Not verified; check product labels |
| Product Status | Industrial machinery-monitoring spare |
| Discontinued Status | Current lifecycle status not verified |
First-Time Operation Inspection Checklist
- 🔍 Verify the complete PR6423/00R-010 and CON021 identification labels.
- 📦 Confirm that the probe and signal converter are supplied as the specified matched assembly.
- 🔧 Inspect the probe tip, threaded housing, cable, connector, and converter enclosure.
- 📏 Confirm the reverse-mount installation dimensions and available clearance.
- ⚙️ Verify the nominal 0.5 mm initial air gap and the correct target material.
- 🔌 Check the converter supply voltage and output wiring against the applicable connection diagram.
- 🧪 Confirm the probe sensitivity and linear measurement range before connecting to the monitoring system.
- 📈 Check the static gap voltage and verify the proportional response over the expected measurement range.
- 🖥️ Confirm monitoring-system scaling, alarm thresholds, and engineering units.
- 🛡️ Verify hazardous-area approvals and any required safety barrier before commissioning.
Daily Maintenance
- Inspect the probe cable and connector for wear, crushing, or mechanical damage.
- Check the probe mounting position and threaded connection for loosening.
- Monitor the gap voltage and shaft displacement trends for unexpected changes.
- Inspect the CON021 converter for loose terminals, contamination, or overheating.
- Review machinery monitoring alarms and investigate abnormal shaft movement.
- Maintain correct cable routing and separation from power cables to reduce electrical interference.
- Check probe and converter connections during scheduled machinery shutdowns.
- Keep records of probe replacement, calibration, air-gap adjustment, and alarm-setting changes.
Troubleshooting and Frequently Asked Questions
Q1: What is the main function of the PR6423/00R-010 + CON021?
It provides non-contact shaft displacement measurement for rotating machinery. Typical applications include radial vibration, axial displacement, shaft position, and eccentricity monitoring.
Q2: What does the 8 mm designation mean?
It identifies the nominal diameter of the PR6423 probe sensing tip.
Q3: What is the measuring range of this assembly?
The standard PR6423 and CON021 combination provides a nominal linear measuring range of 2 mm, with an initial air gap of 0.5 mm.
Q4: What is the difference between PR6423/00 and PR6423/00R?
The R identifies the reverse-mount construction. The mounting arrangement differs, so verify the mechanical installation before substituting one version for the other.
Q5: Which monitoring systems can receive the CON021 output?
The converter provides an analog voltage signal suitable for compatible machinery-monitoring inputs. Verify the required input range, polarity, scaling, and grounding before connecting it to an AMS or other monitoring system.
Q6: Why does the measured gap voltage fluctuate?
Possible causes include excessive probe clearance, loose mounting, damaged cables, electrical interference, an unsuitable shaft target, or converter problems. Check the complete sensor chain before changing alarm settings.
Q7: Can the PR6423 probe operate without the CON021 converter?
The probe requires a compatible signal converter or driver to generate and process its measurement signal. Do not connect the probe directly to a standard analog input.
Q8: Can another PR6423 probe replace this model?
Not automatically. Confirm the mounting style, thread, cable configuration, sensitivity, measuring range, and converter compatibility. A standard-mount probe is not necessarily a mechanical substitute for the reverse-mount version.
Safety Precautions
- ⚠️ Follow the machinery manufacturer’s installation and maintenance procedures.
- 🔒 Isolate relevant equipment and follow lockout/tagout procedures before probe replacement.
- 🛑 Do not install or adjust a probe while rotating machinery is operating unless an approved procedure explicitly permits it.
- 🔌 Observe the converter’s negative DC supply requirements and terminal polarity.
- 🧰 Protect the probe tip and connector from impact, contamination, and electrostatic damage.
- 🛡️ Use approved barriers and installation methods for hazardous-area applications.
- 📘 Preserve the original probe calibration, gap settings, and monitoring-system alarm configuration.
- 🚫 Do not return machinery to service until the complete measurement chain has been checked.
Recommended Emerson / EPRO Related Models
The following models belong to the EPRO eddy-current measurement and machinery-monitoring product families. They are related references, not guaranteed direct replacements.
- Emerson PR6422 – 5 mm Eddy Current Probe
- Emerson PR6423 – 8 mm Eddy Current Probe
- Emerson PR6424 – 11 mm Eddy Current Probe
- Emerson PR6425 – Eddy Current Displacement Probe
- Emerson PR6426 – 25 mm Eddy Current Probe
- Emerson PR6453 – Eddy Current Measurement Probe
- Emerson CON021 – Eddy Current Signal Converter
- Emerson CON021/913-030 – PR6423 Extended-Range Converter
- Emerson CON021/913-040 – PR6423 Extended-Range Converter
- Emerson CON021/914-060 – PR6424 Extended-Range Converter
- Emerson CON021/914-080 – PR6424 Extended-Range Converter
- Emerson CON021/916-120 – PR6426 Extended-Range Converter
- Emerson PR9268/201-000 – EPRO Measurement System Component
- Emerson MMS 6110 – Shaft Relative Vibration Monitor
- Emerson MMS 6210 – Shaft Axial Position Monitor