Description
🔹 Product Overview
The SICK 2038957 is an internal PCB board associated with the SICK ICD880-2112100 industrial image-based code reader. The listing identifies 4047926 as an additional board reference and states that the PCB was salvaged from an ICD880-2112100 reader.
The ICD880-2112100 is an industrial image-based code-reading system for 1D/2D identification applications. Available product references identify it as an image-based code reader with an 80 mm lens and dynamic focus control. The ICD880-2112100 has also been discontinued by the manufacturer, making original internal boards useful for repair and lifecycle support of existing installations.
Because this is an internal PCB removed from a complete reader, it should not be treated as a standalone replacement for every SICK reader. Compatibility should be confirmed against the original ICD880-2112100 unit, PCB markings, connectors, and hardware revision.

📋 Product Datasheet
| Parameter | Details |
|---|---|
| Brand | SICK |
| PCB Part Number | 2038957 |
| Additional Reference | 4047926 |
| Product Type | Internal PCB Board |
| Associated Equipment | ICD880-2112100 |
| Equipment Function | Industrial Image-Based Code Reader |
| Board Application | Internal reader electronics |
| Condition | Salvaged / Used |
| Original Equipment | SICK ICD880-2112100 |
| Dimensions / Weight | Not specified; verify actual board |
⚙️ Key Features
- SICK internal electronic circuit board
- PCB reference 2038957
- Additional reference 4047926
- Salvaged from an ICD880-2112100 reader
- Intended for repair and replacement applications
- Suitable for maintenance of legacy SICK identification equipment
- Useful for component-level repair or reader restoration
- Exact board revision and connector configuration should be verified before installation
🔌 System Integration
The 2038957 / 4047926 board is associated with the internal electronics of the ICD880-2112100 rather than being a general-purpose SICK controller.
The complete ICD880-2112100 is categorized as industrial bar-code equipment / image-based code-reading equipment. Available references identify 1048454 as another associated part number, while the ICD880-2112100 itself is listed as discontinued and replaced by a newer ICD880 variant in one current industrial parts database.
Before installation, compare:
- PCB part number 2038957
- Reference 4047926
- PCB revision
- Connector locations
- Cable connections
- Component layout
- Original ICD880-2112100 model
- Reader serial number
- Existing internal board configuration
Do not assume that a board from a visually similar SICK reader will be electrically interchangeable.
🏭 Industrial Applications
The associated ICD880 platform is designed for industrial identification and code-reading applications, including:
- 1D barcode reading
- 2D code reading
- Production-line identification
- Material tracking
- Packaging inspection
- Factory automation
- Logistics and material handling
- Automated identification systems
- Legacy machine-vision installations
The ICD880-2112100 is specifically described as an image-based code reader and is associated with an 80 mm lens and dynamic focus control.
🛠️ Installation & Maintenance
- Disconnect the ICD880 equipment from all power sources.
- Follow appropriate ESD handling procedures.
- Record the original PCB numbers before removing the existing board.
- Compare 2038957 and 4047926 with the original board.
- Inspect connectors and contacts for oxidation or mechanical damage.
- Check the PCB for cracked components, corrosion, or previous repair work.
- Reconnect all cables according to their original positions.
- Secure the PCB correctly inside the reader housing.
- Perform a controlled power-up.
- Verify reader diagnostics and code-reading operation before returning the machine to service.
🔍 Troubleshooting
The ICD880 does not start after PCB replacement:
Check the board number, connectors, power connections, and compatibility with the original ICD880-2112100 configuration.
The reader powers up but cannot read codes:
Inspect internal connections and confirm that the optical and processing assemblies are correctly connected.
The replacement PCB has different connectors:
Do not modify or force the connections. Verify the board revision and original equipment configuration.
Intermittent operation occurs:
Inspect PCB contacts, connectors, power connections, and signs of contamination or thermal damage.
The board has multiple identification numbers:
Keep 2038957 and 4047926 together in the maintenance record to simplify future replacement identification.
✅ First-Operation Checklist
- ☐ Confirm PCB number 2038957
- ☐ Confirm reference 4047926
- ☐ Verify ICD880-2112100 compatibility
- ☐ Compare PCB revision
- ☐ Check connector locations
- ☐ Inspect PCB condition
- ☐ Verify internal wiring
- ☐ Confirm reader housing and mounting
- ☐ Perform controlled power-up
- ☐ Check diagnostic status
- ☐ Test 1D/2D code-reading operation
❓ FAQ
What is SICK 2038957?
It is an internal PCB board associated with the SICK ICD880-2112100 industrial image-based code reader.
What is 4047926?
The supplied listing identifies 4047926 as an additional reference associated with this internal PCB.
Is 2038957 a complete ICD880 reader?
No. It is an internal circuit board salvaged from an ICD880-2112100 reader.
What equipment was this board removed from?
The listing identifies the source equipment as SICK ICD880-2112100.
Is ICD880-2112100 still a current product?
Available industrial-part references identify the ICD880-2112100 as discontinued by the manufacturer. One current listing identifies ICD880-45152020 as a replacement model.
Can this PCB be installed in another SICK reader?
Compatibility should not be assumed. The board should be matched to the exact reader model, PCB revision, connectors, and internal configuration.
🔧 Related SICK Models & Product Families
- SICK ICD880-2112100
- SICK ICD880 Image-Based Code Reader Series
- SICK ICD880-45152020
- SICK 1048454
- SICK Industrial Image-Based Code Readers
- SICK 1D Code Reading Systems
- SICK 2D Code Reading Systems
- SICK Identification Systems
- SICK Machine Vision Products
- SICK Industrial Automation Electronics
The related models above are product-family references; they should not be considered confirmed substitutes for PCB 2038957.
📦 Spare-Parts & Lifecycle Planning
The ICD880-2112100 is a legacy/discontinued industrial identification platform, so maintaining internal replacement boards can be valuable for plants that still depend on installed readers.
For critical production equipment, record the complete PCB identification:
2038957 / 4047926 → ICD880-2112100
Store the board in ESD-safe packaging and maintain records of its condition, source equipment, PCB revision, and installation history.
For older identification systems, an ABC spare-parts classification can help determine whether internal PCBs should be held as immediate-response inventory. When original equipment is approaching end-of-life, evaluate available replacement readers and migration requirements before existing boards become difficult to source.