Description
🚀 Engineered for precise industrial engine and turbine management, the Woodward 9905-022 is a specialized 2301A Load Sharing and Speed Control module. It operates with an actuator current range of 0–400 mA and requires a minimum system power factor of 0.9 to ensure optimal speed regulation and active electrical load distribution for prime movers operating in parallel.
Technical Specifications & Datasheet
⚙️ Dimensions: 221 mm x 155 mm x 64 mm (Standard 2301A enclosure format)
⚖️ Weight: Approx. 1.8 kg (4 lbs)
🌍 Country of Origin: United States
⚡ Power Consumption: 15 W nominal
🔌 Operating Voltage: Standard low-voltage / high-voltage 2301A system compatibility variants
🌡️ Operating Temperature: -40°C to +85°C (-40°F to +185°F)
🛡️ Enclosure Rating: IP20 chassis-mount with metallic product backplane
⏱️ Actuator Output: 0 to 400 mA current range for compatible proportional actuators
🔄 Speed Range: Rated speed up to 11,450 Hz derived via MPU frequency input
🔌 Minimum Power Factor: Requires \ge 0.9 power factor for accurate load calculation
Operating Procedures & Usage Methods
🛠️ Securely mount the module onto its metallic backplane inside a protective industrial control panel or cabinet, ensuring proper vertical clearance for terminal connections and natural convection cooling.
🔧 Connect the magnetic pickup (MPU) speed sensor, current transformers, 0–400 mA actuator lines, and system power supply strictly according to the terminal wiring diagram on the unit housing.
📋 Adjust the front-panel potentiometers (such as gain, reset, speed trim, and load droop/isochronous settings) carefully during initial calibration to match engine dynamics and synchronization parameters.
Power Sequencing Guidelines
🔌 Startup Sequence: Energize the input power source to initialize internal control circuits, verify that MPU speed signals stabilize within range, and confirm zero fault codes before enabling fuel or steam delivery to the prime mover.
🛑 Shutdown Sequence: Disable the actuator control loop or cut fuel/steam supply to bring the prime mover to a complete, safe stop prior to isolating the main system power feed.
Product Usage Instructions
📖 Ensure the electrical system maintains a minimum power factor of 0.9 during operation so the internal analog circuitry can accurately compute active power for proportional load sharing.
📖 Select isochronous mode when coordinating constant speed across multiple paralleled engines, or use droop mode for single-engine speed governing and isolated electrical generation.
Frequently Asked Questions
💡 Q: What is the actuator current output rating for the 9905-022 model?
A: It is designed to operate with an actuator current range of 0 to 400 mA.
💡 Q: What power factor requirement does this controller have?
A: It requires a minimum system power factor of 0.9 for proper load sharing and power measurement calculations.
💡 Q: What is the primary application of this module?
A: It is used to govern prime mover speed and distribute active electrical load evenly across generators operating in parallel.
Recommended Woodward Series & Industrial Models
- Woodward 2301A Load Sharing and Speed Control 9907-018
- Woodward 2301A Load Sharing and Speed Control 9900-430
- Woodward 2301A Load Sharing and Speed Control 9907-055
- Woodward 2301D Digital Load Sharing and Speed Control 9907-118
- Woodward 2301E Digital Governor 9907-1200
- Woodward MicroNet Digital Controller 5466-258
- Woodward NetCon Control System Processor 5466-500
- Woodward ProTech-GII 8237-1240 Standard Overspeed Trip Device
- Woodward ProTech 203 Model 8200-200 Overspeed Protection System
- Woodward Atlas Digital Control Module 5466-401