🔹 Product Introduction
The KEB Automation 19F6K13-3411 is a COMBIVERT F6 Compact drive controller designed for three-phase AC motor control applications. This configuration is rated for a 400 VAC three-phase input, 60 A output current, and 42 kVA output power, corresponding to a typical 30 kW motor rating. It supports EtherCAT and CAN communication, multiple encoder feedback types, motor temperature monitoring, integrated brake control, and Safe Torque Off (STO). The unit is air-cooled, built-in type, with an IP20 enclosure rating. KEB describes the COMBIVERT F6 as a drive controller combining frequency-inverter and servo-drive functions for a broad range of motor technologies.

KEB AUTOMATION 19F6K13-3411
📋 Product Datasheet
| Parameter | Value |
|---|---|
| Brand | KEB Automation |
| Model | 19F6K13-3411 |
| Series | COMBIVERT F6 |
| Product Name | Compact Drive Controller / Frequency Inverter |
| Place of Manufacture | Germany |
| Product Status | Original / Used or Surplus condition depends on actual unit |
| Dimensions | Approx. 170 × 340 × 261 mm |
| Weight | Verify from the physical unit; configuration dependent |
| Original Country of Origin | Germany |
| Power | 400 VAC, 3-phase, 50/60 Hz; 42 kVA; 60 A output; typical 30 kW motor rating |
The 19F6K13-3411 configuration supports a rated motor power of 30 kW, rated output power of 42 kVA, 60 A rated output current, 150% current regulator limit, and 180% cutoff current. Its maximum output frequency is listed as 599 Hz and rated switching frequency as 2 kHz.
🔧 Troubleshooting & Common Issues
• If the drive does not power up, verify the three-phase input voltage, input protection, terminals, and upstream disconnect.
• If an overcurrent fault occurs, check motor wiring, motor insulation, acceleration settings, load conditions, and mechanical blockage.
• If an overvoltage fault occurs during deceleration, inspect the DC bus condition and braking configuration.
• If the motor does not respond to commands, check the selected control mode, digital inputs, fieldbus communication, and enable/STO status.
• For encoder-related faults, verify encoder type, wiring, feedback supply, and the configured encoder interface.
• If the motor temperature signal is abnormal, inspect the KTY, PTC, or PT1000 sensor wiring and configuration.
• If EtherCAT or CAN communication fails, check cables, node configuration, communication parameters, and the connected controller.
⚠️ Safety Precautions
• Disconnect and isolate the AC power before installation, removal, or maintenance.
• Allow the DC-link capacitors to discharge according to the manufacturer’s specified waiting procedure before opening or servicing the drive.
• Follow applicable lockout/tagout procedures.
• Use appropriate ESD protection when handling the control electronics.
• Verify input voltage, phase configuration, motor rating, and wiring before energizing the drive.
• Do not bypass the integrated STO safety function or other protective circuits.
• Use appropriately rated cables, protective devices, grounding, and braking components.
• Perform controlled commissioning and motor-direction checks before placing the machine into normal operation.
📰 Product-Related News & Industry Context
KEB’s current COMBIVERT F6 platform combines frequency-inverter and servo-drive functions and covers a broad power range from 2.2 kW to 450 kW for 400 V-class systems. Depending on the device variant, F6 controllers support communication technologies including EtherCAT, PROFINET, EtherNet/IP, Modbus/TCP, POWERLINK, and VARAN, together with CAN and diagnostic interfaces.
The 19F6K13-3411 represents a 400 V, 42 kVA configuration within the F6 family. Its documented feature set includes EtherCAT/CAN communication, CiA 402 drive profile support, two-channel multi-encoder capability, 24 V/2 A brake control, KTY/PTC/PT1000 motor-temperature input, integrated brake transistor, and STO safety functionality.
❓ Q&A
Q: What is the KEB 19F6K13-3411?
A: It is a KEB Automation COMBIVERT F6 Compact drive controller for three-phase AC motor applications.
Q: What is its motor power rating?
A: The listed configuration has a typical rated motor power of 30 kW for a 2/4-pole motor at 50/60 Hz.
Q: What is the output current?
A: The rated output current is 60 A.
Q: What is the input voltage?
A: The specified input is 400 VAC, three-phase, 50/60 Hz.
Q: What communication interfaces are available?
A: This configuration is listed with EtherCAT and CAN communication. The wider F6 family supports additional communication options depending on the control-card and device variant.
Q: Does it support encoder feedback?
A: Yes. The 19F6K13-3411 is listed with a two-channel multi-encoder interface supporting compatible feedback configurations.
Q: What motor-temperature sensors are supported?
A: The listed configuration supports KTY, PTC, and PT1000 motor-temperature sensors.
Q: Does it have a safety function?
A: Yes. The configuration includes Safe Torque Off (STO).
Q: What is the enclosure rating?
A: The listed configuration has an IP20 protection rating and an air-cooled built-in design.
Q: Is 19F6K13-3411 discontinued?
A: The available KEB material confirms that the COMBIVERT F6 family remains an active product platform, but the exact production status of this specific 19F6K13-3411 ordering configuration should be verified from its nameplate and current KEB documentation.
⭐ Recommended KEB Automation Models
- KEB 19F6K13-3413 — COMBIVERT F6 Drive Controller
- KEB 18F6K1R-76MA — COMBIVERT F6 Drive Controller
- KEB 17F6K1H-19MA — COMBIVERT F6 Drive Controller
- KEB 16F6K1H-1BMA — COMBIVERT F6 Drive Controller
- KEB 15F6K1G-19MA — COMBIVERT F6 Drive Controller
- KEB 14F6K1E-15MA — COMBIVERT F6 Drive Controller
- KEB 13F6K1E-16MA — COMBIVERT F6 Drive Controller
- KEB 12F6K1E-1AMA — COMBIVERT F6 Drive Controller
- KEB 10F6K1D-3411 — COMBIVERT F6 Drive Controller
- KEB 09F6K1D-2BMA — COMBIVERT F6 Drive Controller