The ABB PM864AK01 (3BSE018161R1) is a processor unit package for the ABB AC 800M controller platform, used in System 800xA and related industrial automation installations. It is built around the PM864A CPU, which executes control applications, manages controller communications, and coordinates connected I/O and communication modules.
The processor operates at 96 MHz and has 32 MB of memory. Its TP830 baseplate provides Ethernet and serial communication connections, while the controller architecture supports CEX-Bus, ModuleBus, and RCU-Link connections. The PM864A also supports CPU redundancy in appropriately configured AC 800M systems.
The complete PM864AK01 package is more than the CPU board alone. ABB’s product information identifies the package contents as the PM864A CPU, TP830 baseplate, TB850 CEX-Bus terminator, TB807 ModuleBus terminator, TB852 RCU-Link terminator, memory-backup battery, and four-position power connector. Confirm the actual contents when purchasing a used or surplus unit.
For maintenance and replacement work, verify the controller firmware, Control Builder configuration, baseplate connections, redundancy arrangement, and installed system version before commissioning.

PM864AK01 3BSE018161R1
Product Datasheet
- Brand: ABB
- Model: PM864AK01
- Order Number: 3BSE018161R1
- Product Name: AC 800M Processor Unit
- Product Family: ABB AC 800M / System 800xA
- Product Type: Central Processing Unit (CPU) Package
- CPU Module: PM864A
- Processor Frequency: 96 MHz
- Memory: 32 MB
- Baseplate: TP830, 115 mm wide
- Ethernet Interfaces: 2 × RJ45
- Serial Interfaces: 2 × RJ45
- Serial Interface Details: COM3 RS-232C; COM4 isolated configuration-tool interface
- Internal Buses: CEX-Bus, ModuleBus, and RCU-Link
- Redundancy: CPU redundancy supported
- Configuration Environment: ABB Control Builder
- Memory Backup: Battery, part number 4943013-6
- Included Terminators: TB850, TB807, and TB852
- Power Connector: 4-position plug, 3BSC840088R4
- Protection Class: IP20 system installation
- Mounting: TP830 baseplate with DIN-rail attachment
- Product Lifecycle: Classic; replacement available
- Replacement Reference: PM862K01, 3BSE076940R1 (migration assessment required)
- Dimensions: Package dimensions depend on the supplied components; verify before installation
- Weight: Approximately 1.2 kg, supplier-listed
- Country of Origin: Verify from the product label and shipment documentation
- Condition: Confirm whether the supplied unit is new, surplus, or refurbished
Technical Features & Specifications
96 MHz AC 800M Processing
The PM864A processor executes the configured control application and coordinates communication with connected I/O and interface modules. Its 32 MB memory supports controller application data and execution requirements. Actual available application memory depends on firmware and system configuration.
Ethernet and Serial Communication
The TP830 baseplate provides two RJ45 Ethernet ports, CN1 and CN2, for control-network connectivity. It also provides two RJ45 serial connections:
- COM3: RS-232C interface with modem control signals.
- COM4: Isolated serial interface used for configuration-tool connection.
Check port assignments, cable pinouts, and network configuration against the system drawings before reconnecting existing cables.
CEX-Bus and ModuleBus Architecture
The AC 800M platform uses internal communication buses to connect compatible communication interfaces and I/O modules. The PM864AK01 package includes the relevant bus terminators:
- TB850: CEX-Bus terminator.
- TB807: ModuleBus terminator.
- TB852: RCU-Link terminator.
Correct termination and module placement are important for reliable controller operation.
CPU Redundancy
The PM864A supports redundant controller configurations when used with compatible hardware and correctly engineered system settings. Redundancy requires matching processor types within the redundant pair. Confirm the applicable controller configuration, firmware, communication modules, and switchover behavior before replacing either CPU.
Configuration and Engineering
ABB Control Builder is used to configure the AC 800M controller and its application. Before replacement, preserve the application project, controller settings, communication parameters, and firmware information. A replacement CPU may require engineering and commissioning work rather than a simple hardware exchange.
Application Scenarios & Pain Points
- Process automation: Executes control logic for continuous production and process equipment.
- Distributed control systems: Functions as the central controller in compatible ABB System 800xA installations.
- Power and utility systems: Supports controller-based monitoring and automation when included in an engineered AC 800M system.
- Manufacturing lines: Coordinates connected I/O, communication interfaces, and machine-control sequences.
- Legacy system maintenance: Provides a spare processor package for existing installations using the PM864A hardware platform.
Typical maintenance challenges include CPU faults, battery-related memory retention issues, communication interruptions, incorrect bus termination, and configuration incompatibility after replacement. Maintaining a verified controller backup and hardware inventory helps reduce commissioning risk.
First-Time Installation Checklist
- Verify the complete model and order number: PM864AK01, 3BSE018161R1.
- Inspect the CPU, TP830 baseplate, connectors, battery, and terminators.
- Confirm the supplied package contents against the original bill of materials.
- Verify the AC 800M controller hardware configuration and firmware version.
- Back up the existing application, configuration, and communication settings.
- Confirm the power supply specification and connector pinout using ABB documentation.
- Check Ethernet addressing, network topology, and serial cable assignments.
- Verify CEX-Bus, ModuleBus, and RCU-Link connections and termination.
- Confirm that redundant CPU arrangements use matching processor types.
- Load or restore the approved controller configuration using the applicable ABB engineering tools.
- Check CPU status indicators, communication links, and I/O availability.
- Perform controlled functional testing before returning the controller to production service.
Daily Maintenance
- Monitor CPU status LEDs and controller diagnostic messages.
- Check Ethernet and serial communication for intermittent faults.
- Inspect baseplate connections and internal bus interfaces during planned shutdowns.
- Review battery status and replace the backup battery according to ABB maintenance instructions.
- Keep the controller enclosure clean and within its specified operating environment.
- Maintain current backups of application programs, hardware configuration, and firmware records.
- Record controller switchover events and communication alarms.
- Verify that bus terminators remain correctly installed after maintenance work.
Troubleshooting & Frequently Asked Questions
Q1: What is the main function of the PM864AK01?
It is the processor unit package for an ABB AC 800M controller. The PM864A CPU executes control applications and manages communication with connected automation hardware.
Q2: What are its CPU speed and memory capacity?
The PM864A operates at 96 MHz and has 32 MB of memory.
Q3: What components are included in the PM864AK01 package?
The documented kit includes the PM864A CPU, TP830 baseplate, TB850, TB807, TB852 terminators, memory-backup battery, and four-position power connector. Verify the physical contents of the supplied unit.
Q4: Does it support redundant CPU operation?
Yes. CPU redundancy is supported in compatible AC 800M configurations. Both processors in a redundant pair must be the same type.
Q5: What communication ports are available?
The TP830 baseplate provides two RJ45 Ethernet ports and two RJ45 serial ports. COM3 is RS-232C, while COM4 is an isolated configuration-tool interface.
Q6: Can PM864AK01 be replaced by PM862K01?
ABB identifies PM862K01 (3BSE076940R1) as a replacement reference. However, this is a migration, not an automatic drop-in substitution. Check system version, firmware, application compatibility, baseplate and I/O configuration, and redundancy requirements. ABB indicates PM862 support from System 800xA version 6.0.2.
Q7: Why does the controller fail to start after installation?
Possible causes include incorrect power connections, missing or incorrectly installed bus terminators, incompatible firmware, faulty memory backup, or an incorrect hardware configuration. Review controller diagnostics and the installation drawings.
Q8: What should be checked before replacing a PM864A CPU?
Back up the application, record firmware and hardware revisions, identify all connected buses and communication modules, and confirm whether the controller is part of a redundant pair.
Safety Precautions
- Isolate power according to the plant’s approved maintenance procedure before removing or installing the processor.
- Use ESD protection when handling the CPU and baseplate.
- Verify power connector pin assignments before energizing the unit.
- Install the correct CEX-Bus, ModuleBus, and RCU-Link terminators.
- Follow ABB instructions when replacing the memory-backup battery.
- Do not mix different processor types in a redundant pair.
- Confirm application and firmware compatibility before loading a controller configuration.
- Test controller operation and communication under controlled conditions before restoring process control.
Recommended Related Models & Components
The following ABB products belong to the AC 800M controller and associated automation hardware families. They are related components, not all direct replacements for PM864AK01.
- ABB PM861AK01 – AC 800M Processor Unit
- ABB PM866AK01 – AC 800M Processor Unit
- ABB PM862K01 – AC 800M Processor Unit and replacement reference
- ABB PM858K01 – AC 800M Processor Unit
- ABB TP830 – Processor Baseplate
- ABB TB850 – CEX-Bus Terminator
- ABB TB807 – ModuleBus Terminator
- ABB TB852 – RCU-Link Terminator
- ABB BC810 – CEX-Bus Communication Interface
- ABB CI854A – PROFIBUS DP/V1 Communication Interface
- ABB CI867K01 – Modbus TCP Communication Interface
- ABB CI868K01 – IEC 61850 Communication Interface
- ABB AI810 – Analog Input Module
- ABB DI810 – Digital Input Module
- ABB DO810 – Digital Output Module