Description

Product Description

The Woodward 9907-1200 is a CPC-II Current-to-Pressure Converter with Enhanced Dynamics, designed for electro-hydraulic control of steam turbine valves, fuel valves, and associated servo systems.

The unit converts a 4–20 mA electrical demand signal into a proportional hydraulic control pressure. Its internal electronic control circuit, pressure sensor, rotary hydraulic valve, and actuator work together to regulate oil pressure and position single-acting turbine valve servos.

The 9907-1200 is the 10-bar CPC-II version intended for specified hazardous-area installations. It supports turbine speed and load control applications where accurate hydraulic pressure regulation is required.

The CPC-II also provides diagnostic functions, configurable analog and discrete outputs, and an optional redundant setpoint or feedback input. Its enhanced-dynamics design supports pressure control adjustments through Woodward’s PC-based service tool.

This model is suitable for turbine control-system maintenance, CPC replacement projects, and electro-hydraulic actuator applications requiring the correct 10-bar pressure range and hazardous-area classification.

9907-1200

9907-1200

Product Datasheet

  • Brand: Woodward
  • Model: 9907-1200
  • Product Series: CPC-II
  • Product Name: Current-to-Pressure Converter with Enhanced Dynamics
  • Product Type: Electro-Hydraulic Pressure Converter
  • Control Input: 4–20 mA DC
  • Redundant Input: 4–20 mA DC
  • Analog Output: 4–20 mA DC
  • Supply Voltage: 18–32 V DC, 24 V DC nominal
  • Steady-State Power Consumption: 25 W
  • Maximum Control Pressure: 0–10 bar (0–145 psi)
  • Supply Pressure Rating: 10 bar (145 psi)
  • Pressure Control Medium: Hydraulic oil
  • Hydraulic Valve: Three-way rotary valve
  • Enclosure Protection: IP66
  • Hazardous-Area Classification: Class I, Division 2; ATEX Zone 2 version
  • Operating Ambient Temperature: -40 to +85 °C
  • Oil Temperature: 15 to +70 °C
  • Dimensions: Approximately 270 × 270 × 290 mm
  • Weight: Approximately 25 kg without oil
  • Cable Entries: Two 3/4-inch NPT threaded ports
  • Product Status: Verify current lifecycle status with Woodward
  • Country of Origin: Not independently verified

 

Technical Features & Specifications

  • Current-to-pressure conversion: Converts a 4–20 mA command signal into proportional hydraulic control pressure.
  • 10-bar pressure range: Designed for applications requiring a control pressure range up to 10 bar.
  • Enhanced dynamic response: Electronic pressure regulation supports accurate turbine valve positioning.
  • Pressure feedback: Integrated pressure sensing supports closed-loop pressure control.
  • Redundant signal capability: A second analog input can be configured for redundant demand or feedback.
  • Diagnostic monitoring: Internal diagnostics monitor supply voltage, signal validity, and converter operating conditions.
  • Analog output: Configurable 4–20 mA output for pressure-related monitoring.
  • Discrete outputs: Configurable normally open or normally closed outputs for alarm and fault indication.
  • Hydraulic valve assembly: Three-way rotary valve regulates supply, control, and drain flow.
  • Fail-safe behavior: An internal return spring moves the hydraulic valve to route control pressure to drain when the unit is unpowered.
  • Service configuration: Woodward PC Service Tool supports diagnostics, pressure-demand scaling, redundancy configuration, and dynamic adjustment.
  • Environmental protection: IP66 enclosure for demanding industrial turbine installations.

 

Application Scenarios & Pain Points

  • Steam turbine governor valve positioning.
  • Turbine fuel valve and servo-system hydraulic pressure control.
  • Power generation turbine speed and load regulation.
  • Industrial turbine electro-hydraulic control systems.
  • Replacement of older current-to-pressure converters.
  • Turbine maintenance projects requiring a 10-bar CPC-II configuration.
  • Applications requiring hazardous-area-rated control equipment.

The 9907-1200 addresses the need to translate an electronic control demand into stable hydraulic pressure. Correct pressure range, oil supply conditions, and valve-servo compatibility are essential when replacing an existing converter.

 

First-Time Installation Checklist

  1. Confirm the complete part number is 9907-1200.
  2. Verify the 10-bar supply and control pressure configuration.
  3. Confirm that the hazardous-area classification matches the installation requirements.
  4. Check the 18–32 V DC power supply and grounding arrangement.
  5. Verify the 4–20 mA command signal and optional redundant input configuration.
  6. Inspect the hydraulic supply, control, and drain connections.
  7. Confirm that the mounting adapter or manifold matches the three hydraulic ports.
  8. Check hydraulic oil cleanliness and external filter condition.
  9. Verify cable entries, seals, and enclosure cover condition.
  10. Configure the pressure demand scaling and dynamic settings using the appropriate CPC-II Service Tool.
  11. Perform pressure-response and valve-position tests under an approved commissioning procedure.

 

Daily Maintenance

  • Monitor hydraulic control pressure and valve-position response.
  • Check for abnormal pressure fluctuations or unstable valve operation.
  • Inspect hydraulic connections for leakage.
  • Maintain the recommended oil cleanliness and external filtration.
  • Review diagnostic indications and alarm outputs.
  • Inspect electrical connections and grounding.
  • Check the enclosure seals and cable entries for damage.
  • Record operating pressure, fault history, and maintenance adjustments.

 

Troubleshooting & Frequently Asked Questions

Q1: What is the function of Woodward 9907-1200?

It is a CPC-II current-to-pressure converter that translates a 4–20 mA control signal into hydraulic pressure for turbine valve and servo positioning.

Q2: What is the pressure range of the 9907-1200?

It is the 10-bar version, with a control pressure range of 0–10 bar (0–145 psi).

Q3: What is its operating voltage?

The manufacturer specifies an 18–32 V DC supply, with 24 V DC nominal.

Q4: Does the 9907-1200 support redundant inputs?

Yes. Its second analog input can be configured for redundant setpoint or pressure feedback, depending on the application configuration.

Q5: What is the difference between 9907-1200 and 9907-1199?

Both are 10-bar CPC-II models, but their hazardous-area classifications differ. The 9907-1200 is the Class I, Division 2 / ATEX Zone 2 version, while the 9907-1199 is the Class I, Division 1 and 2 / ATEX Zone 1 and 2 version. They should not be substituted without checking the installation certification requirements.

Q6: Can the 9907-1200 replace an older Woodward CPC converter?

Yes, Woodward’s CPC-II interchange documentation identifies the 9907-1200 as a replacement for certain older 10-bar CPC configurations, including 9907-1106. The original pressure range, area classification, and mounting arrangement must be checked.

Q7: What should be checked if the output pressure is unstable?

Inspect the hydraulic supply pressure, oil cleanliness, external filter, drain pressure, signal scaling, pressure feedback, and configured dynamic settings. Review the CPC-II diagnostics before making adjustments.

Q8: Does the converter require a separate hydraulic manifold?

Yes. It mounts to a compatible adapter block or hydraulic manifold that connects the supply, control, and drain ports.

 

Safety Precautions

  • Installation and commissioning must be performed by qualified turbine-control and hydraulic-system personnel.
  • Isolate electrical and hydraulic energy before servicing the unit.
  • Never disconnect electrical connections in a hazardous area while energized unless the applicable protection requirements explicitly permit it.
  • Observe the specified hazardous-area certification for the exact model.
  • Use suitable hydraulic oil and maintain the required filtration and cleanliness.
  • Never exceed the rated supply or control pressure.
  • Verify grounding, cable-entry seals, and enclosure cover torque.
  • Maintain an independent overspeed shutdown device for the prime mover.
  • Complete turbine valve and safety-system functional testing before returning the equipment to service.

 

Recommended Related Models & Components

The following models belong to the Woodward CPC and turbine hydraulic-control product family. Their pressure ranges, redundancy arrangements, and hazardous-area classifications differ.

  • Woodward 9907-1199 – CPC-II, 10-bar, Zone 1 and Zone 2
  • Woodward 9907-1198 – CPC-II, 25-bar, Zone 2
  • Woodward 9907-1197 – CPC-II, 25-bar, Zone 1 and Zone 2
  • Woodward 9907-1253 – Dual-Redundant CPC-II, 10-bar
  • Woodward 9907-1254 – Dual-Redundant CPC-II, 25-bar
  • Woodward 9907-1228 – CPC-II, 10-bar model
  • Woodward 9907-1349 – CPC-II, 10-bar model
  • Woodward 9907-1106 – Older CPC converter
  • Woodward 9907-1102 – Older CPC converter, 25-bar configuration
  • Woodward 9907-1103 – Older CPC converter
  • Woodward 9907-1100 – Older CPC converter
  • Woodward 8928-7240 – Voith E360 I/H converter adapter kit
  • Woodward 8923-2276 – CPC-1 converter manifold adapter kit
  • Woodward 8918-116 – CPC-DX dual-redundant skid, 10-bar
  • Woodward 8918-118 – CPC-DX dual-redundant skid, 25-bar
about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.