Description
Product Description
The ABB TB807 (3BSE008538R1) is a passive Modulebus Terminator designed for ABB S800 I/O system installations. It provides the required electrical termination at the designated end of a Modulebus communication segment, helping maintain signal integrity and stable communication between connected I/O components.
Unlike an active communication interface or PLC controller, the TB807 does not process control logic or provide independent I/O channels. Its purpose is to complete the Modulebus termination arrangement according to the system configuration.
The TB807 is a compact accessory used in ABB distributed control and process automation installations. Correct placement and compatibility with the applicable Modulebus assembly are important for reliable system operation.

3BSE008538R1
Key Technical Specifications
- Brand: ABB
- Model: TB807
- Order Number: 3BSE008538R1
- Alternate Ordering Reference: 3BSE008538R0001
- Product Name: Modulebus Terminator
- Product Type: Passive Module Termination Unit
- Product Family: ABB S800 I/O
- Application: Modulebus communication-line termination
- Function: Electrical termination of the Modulebus segment
- Operating Principle: Passive; no independent control processing
- Connector: Internal Modulebus connection; verify the exact mounting interface
- Operating Temperature: 0 to +55 °C, according to supplier-published product data
- Protection Class: IP20
- Dimensions: Approximately 13 × 17 × 19 mm
- Net Weight: Approximately 0.01 kg
- Country of Origin: Verify the individual product label and ABB supply record
- Product Status: Industrial automation spare part
Key Features
- Passive termination accessory for ABB Modulebus installations.
- Supports correct electrical termination of the designated communication segment.
- Helps reduce signal reflections associated with unterminated bus connections.
- Compact construction for installation within compatible ABB I/O assemblies.
- No independent processor or application configuration required.
- Suitable for maintenance, system expansion, and replacement of missing or damaged terminators.
Application Scenarios
- ABB S800 I/O distributed control systems.
- Modulebus termination in industrial process automation cabinets.
- Maintenance of ABB Advant and compatible control-system installations.
- Replacement of a missing or damaged Modulebus terminator.
- Spare-parts inventory for power generation, chemical processing, water treatment, and manufacturing facilities.
Installation and Commissioning
- Identify the installed ABB I/O system and the relevant Modulebus segment.
- Confirm that TB807 is the specified terminator for the exact assembly.
- Review the system layout to identify the designated termination position.
- Isolate the relevant equipment according to the manufacturer’s maintenance procedure.
- Inspect the mounting interface and connector for contamination or mechanical damage.
- Install the TB807 in the specified position and ensure that it is fully seated.
- Restore the system according to the approved commissioning procedure.
- Check I/O communication diagnostics and confirm that the Modulebus segment operates normally.
Do not install additional terminators at arbitrary positions. The number and location of terminators must follow the ABB system configuration.
Daily Maintenance
- Check Modulebus communication diagnostics for intermittent faults.
- Inspect the terminator and its mounting interface during scheduled shutdowns.
- Keep the surrounding I/O assembly clean and free from conductive contamination.
- Check for loose or damaged mounting connections.
- Confirm that the terminator remains installed in the designated position after system modifications.
- Maintain spare units in clean, dry storage.
Troubleshooting and FAQ
Q1: What is the function of ABB TB807?
The TB807 terminates a Modulebus communication segment in compatible ABB I/O installations.
Q2: Is TB807 an active communication module?
No. It is a passive termination unit. It does not operate as a fieldbus controller, communication processor, or PLC interface.
Q3: Which ABB system uses the TB807?
It is associated with the ABB S800 I/O system and related Modulebus configurations. Confirm the exact system arrangement before installation.
Q4: Does the TB807 require a separate power supply?
No independent power supply is required for its passive termination function.
Q5: What can happen if the Modulebus is not correctly terminated?
Incorrect termination can contribute to communication instability, signal reflections, and intermittent I/O communication faults.
Q6: Can TB807 replace any ABB bus terminator?
No. Termination components are interface-specific. Verify the exact Modulebus type, mounting arrangement, and part number before substitution.
Q7: Does the TB807 require software configuration?
No application programming is normally required. Correct physical placement within the Modulebus arrangement is the key installation requirement.
Safety Precautions
- Follow ABB system documentation and site electrical isolation procedures.
- Do not remove or install the terminator on energized equipment unless the manufacturer explicitly permits it.
- Verify the correct Modulebus segment and termination position before installation.
- Avoid forcing the component into an incompatible connector.
- Inspect the connector and mounting interface before restoring power.
- Confirm normal communication diagnostics after maintenance.
Recommended Related Models
The following are related ABB S800 I/O and control-system components. They are useful for system maintenance and spare-parts planning, but they are not direct replacements for TB807.
- CI810B 3BSE020520R1 – AF100 Fieldbus Communication Interface
- CI801 3BSE022366R1 – S800 I/O Fieldbus Communication Interface
- CI840A 3BSE041882R1 – Redundant PROFIBUS-DP Communication Interface
- TB820V2 3BSE013208R1 – Modulebus Optical Port
- TB825 3BSE036634R1 – Modulebus Optical Port
- TB840A 3BSE037760R1 – Redundant Modulebus Modem
- TB811 3BSE008516R1 – Modulebus Terminator
- TB806 3BSE008536R1 – Modulebus accessory reference
- TU810V1 3BSE013230R1 – Compact Module Termination Unit
- TU812V1 3BSE013232R1 – Compact Module Termination Unit
- TU830V1 3BSE013234R1 – Extended Module Termination Unit
- TU842 3BSE020850R1 – Redundant Module Termination Unit
- AI810 3BSE008516R1 – Analog Input Module; verify ordering number before listing
- DI810 3BSE008508R1 – Digital Input Module
- DO810 3BSE008510R1 – Digital Output Module
Inspection and Quality Control
Before shipment or installation, verify:
- ABB identification: TB807.
- Complete ordering number: 3BSE008538R1.
- Connector and mounting-interface condition.
- No visible cracks, deformation, or contamination.
- Correct part number against the installed system documentation.
- Functional communication checks after installation, where applicable.
For replacement planning, confirm the installed ABB I/O assembly and Modulebus configuration before ordering.