Description
Product Description
The Bently Nevada 3500/22M 288055-01 is a Standard Transient Data Interface (TDI) module designed for the Bently Nevada 3500 Machinery Protection System.
The TDI provides the communication interface between the 3500 monitoring rack and compatible software, including System 1 Condition Monitoring and Diagnostic Software and 3500 System Configuration Software. It combines the rack-interface functions of the 3500/20 Rack Interface Module (RIM) with the data collection capabilities of a communication processor.
The module continuously collects steady-state information and transient dynamic data, including waveform information, from compatible M-series monitor modules. It transfers this information through an Ethernet connection for remote monitoring, equipment diagnostics, and machinery condition analysis.
The 3500/22M occupies Slot 1, adjacent to the rack power supplies. Every compatible 3500 rack requires one TDI or RIM. The TDI supports standard static data collection, while dynamic and high-resolution transient data collection requires the appropriate optional Channel Enabling Disk.
The 288055-01 is the standard TDI module supplied with a specified USB cable. The rear Ethernet I/O module determines whether the network connection uses copper Ethernet or fiber-optic Ethernet.

BENTLY 3500/22M 288055-01
Product Datasheet
| Parameter | Description |
|---|---|
| Brand | Bently Nevada |
| Model | 3500/22M |
| Part Number | 288055-01 |
| Product Name | Transient Data Interface Module |
| Product Type | Standard TDI Module |
| Product Series | 3500 Machinery Protection System |
| Primary Function | Rack communication and transient data collection |
| Rack Position | Slot 1, adjacent to power supplies |
| Compatible Software | System 1 and 3500 System Configuration Software |
| Front USB Interface | USB Type-B |
| Ethernet Interface | 10Base-T / 100Base-TX or 100Base-FX, depending on rear I/O module |
| Power Consumption | 10.5 W |
| Operating Temperature | -30 to +65 °C |
| Storage Temperature | -40 to +85 °C |
| Relative Humidity | Up to 95%, non-condensing |
| Dimensions | 241.3 × 24.4 × 241.8 mm |
| Weight | Approximately 0.91 kg |
| Included Accessory | Specified USB A-to-B cable |
| Product Status | Current lifecycle status not independently confirmed |
Technical Features & Specifications
- Transient Data Interface: Connects the 3500 monitoring rack to compatible condition monitoring and configuration software.
- Rack Interface Function: Combines functions associated with the 3500/20 Rack Interface Module and communication processor capabilities.
- Steady-State Data Collection: Collects standard monitoring information from compatible M-series monitor modules.
- Transient Waveform Collection: Supports dynamic waveform acquisition when the appropriate channel-enabling option is installed and configured.
- Ethernet Communication: Transfers collected monitoring data through a compatible Ethernet I/O module.
- USB Configuration Interface: Provides a front-panel USB Type-B connection for configuration and maintenance access.
- M-Series Monitor Integration: Interfaces with compatible monitor modules such as the 3500/40M and 3500/42M.
- Rack Installation: Occupies Slot 1, immediately adjacent to the power supplies. A compatible 3500 rack requires one TDI or RIM.
- Diagnostic Indicators: Front-panel indicators provide information about module operation, communication, configuration, and data collection status.
- Rear I/O Options: Copper Ethernet and fiber-optic Ethernet configurations are available through the corresponding rear I/O module.
- System Protection Independence: The TDI is not part of the critical machinery protection path. Its removal or failure does not replace or disable the independent monitoring and protection functions of the other rack modules.
- Channel Enabling: Optional Channel Enabling Disk functionality allows additional dynamic and high-resolution transient data collection.
Application Scenarios
- Turbine condition monitoring: Transfers vibration and machinery monitoring data from compatible turbine monitoring racks to System 1.
- Compressor monitoring: Supports collection and analysis of steady-state and transient operating information.
- Generator protection support: Provides data communication for machinery condition monitoring installations.
- Oil and gas facilities: Connects 3500 monitoring racks with centralized diagnostic and maintenance systems.
- Power generation plants: Supports remote analysis of rotating equipment condition and operating events.
- Petrochemical plants: Provides monitoring data access for predictive maintenance and machinery diagnostics.
- Industrial maintenance systems: Supports configuration, monitoring, and historical data collection from compatible 3500 racks.
First-Time Installation Checklist
- Verify the complete part number 288055-01 and model designation 3500/22M.
- Confirm that the installed rack is a compatible Bently Nevada 3500 system.
- Check that Slot 1 is the correct installation position.
- Verify the rear Ethernet I/O module and determine whether the rack uses copper or fiber-optic Ethernet.
- Confirm that the Ethernet I/O module and rear connection are compatible with the intended network.
- Inspect the front and rear connectors for damage or contamination.
- Check the USB cable and confirm that the correct connection is available for configuration.
- Verify firmware and software compatibility with the installed System 1 and 3500 configuration environment.
- Confirm whether an optional Channel Enabling Disk is required for the intended transient data collection functions.
- Follow the approved Bently Nevada installation and configuration procedure.
- Verify the OK, TX/RX, TM, and CONFIG OK indicators after installation.
- Confirm successful rack communication and data transfer before completing commissioning.
Daily Maintenance
- Monitor the OK, TX/RX, TM, and CONFIG OK indicators for abnormal status.
- Review communication alarms and diagnostic messages.
- Check Ethernet cable connections and network link status.
- Inspect the USB configuration connection when maintenance access is required.
- Verify that System 1 receives the expected monitoring data.
- Review transient waveform collection and channel availability.
- Keep the rack cabinet clean, dry, and within the specified environmental limits.
- Check rear I/O connections for looseness or physical damage during scheduled maintenance.
- Record firmware revisions, configuration changes, and module replacement history.
- Do not remove or replace the TDI without following the approved rack maintenance procedure.
Troubleshooting & Frequently Asked Questions
Q1: What is the primary function of the Bently Nevada 3500/22M?
A: It provides the interface between the 3500 monitoring rack and compatible software, while collecting and transferring steady-state and transient dynamic data.
Q2: What is the difference between the 3500/22M and 3500/20?
A: The 3500/20 is the Rack Interface Module (RIM), while the 3500/22M combines rack-interface functions with communication processor and data collection capabilities.
Q3: Where is the 3500/22M installed?
A: It occupies Slot 1 of the 3500 rack, next to the power supplies.
Q4: Does the 3500/22M perform machinery protection trips?
A: No. The TDI is not part of the critical machinery protection path. Dedicated monitor and relay modules perform the associated protection functions.
Q5: Does the 288055-01 support Ethernet communication?
A: Yes. The Ethernet connection is provided through the compatible rear I/O module. Copper 10Base-T/100Base-TX and 100Base-FX fiber-optic options are available.
Q6: Can the 3500/22M collect transient waveform data?
A: Yes. Standard static data collection is included. Dynamic and high-resolution transient data collection requires the appropriate Channel Enabling Disk and compatible configuration.
Q7: Which monitor modules can communicate with the TDI?
A: It interfaces with compatible M-series monitors, including the 3500/40M and 3500/42M. Confirm the full rack configuration and firmware compatibility.
Q8: What is the function of the USB port?
A: The front USB Type-B port provides a connection for configuration and maintenance activities using compatible software and the specified USB cable.
Q9: What should be checked if the TX/RX indicator shows abnormal activity?
A: Check rack communication, rear Ethernet I/O connections, network cabling, software configuration, and the status of the associated monitoring modules.
Safety Precautions
- Follow the approved Bently Nevada 3500 rack maintenance procedure before removing or installing the module.
- Confirm the rack’s electrical and maintenance safety requirements before handling the hardware.
- Use suitable electrostatic discharge protection when handling electronic modules.
- Do not disconnect rear I/O connections while energized unless an approved procedure permits it.
- Avoid modifying rack configuration or communication settings without authorization.
- Verify firmware and software compatibility before commissioning.
- Remember that the TDI is not a substitute for the rack’s dedicated machinery protection modules.
- Only qualified instrumentation and machinery protection personnel should perform installation and troubleshooting.
Recommended Related Models & Components
The following modules and accessories are associated with the Bently Nevada 3500 Machinery Protection System. They support rack communication, monitoring, configuration, and data acquisition. They are not direct replacements for the 3500/22M unless specifically identified.
- 3500/20 – Rack Interface Module (RIM)
- 146031-01 – 10Base-T/100Base-TX Ethernet I/O Module
- 146031-02 – 100Base-FX Fiber-Optic Ethernet I/O Module
- 146031-03 – 10Base-T/100Base-TX Ethernet I/O Module, gold-plated version
- 146031-04 – 100Base-FX Fiber-Optic Ethernet I/O Module, gold-plated version
- 3500/40M – Proximitor Monitor
- 3500/42M – Proximitor/Seismic Monitor
- 3500/45 – Position Monitor
- 3500/50M – Tachometer Module
- 3500/53 – Overspeed Detection System
- 3500/60 – Temperature Monitor
- 3500/62 – Process Variable Monitor
- 3500/65 – Temperature Monitor
- 3500/32M – 4-Channel Relay Module
- 3500/33 – 16-Channel Relay Module