Description
Product Description
The Bosch Rexroth FCS01.1E-W0011-A-04-NNBV (R911311065) is an IndraDrive Fc compact frequency converter designed to control the speed of three-phase AC induction motors in industrial automation systems. With a rated motor power of 2.2 kW and a 380–480 V AC three-phase supply, this drive is suitable for applications requiring adjustable motor speed, controlled acceleration and deceleration, and integration with machine-level control systems.
The drive supports V/f and sensorless vector control. Its control interfaces include configurable digital and analog I/O, relay outputs, and RS-232/RS-485 serial communication. DC bus connections also support common DC bus configurations where the system design permits.
Typical applications include pumps, fans, conveyors, mixers, and other industrial machinery. Before installation, verify the motor nameplate, load characteristics, supply voltage, control configuration, and braking requirements.

FCS01.1E-W0011-A-04-NNBV
Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Bosch Rexroth |
| Model | FCS01.1E-W0011-A-04-NNBV |
| Material Number | R911311065 |
| Product Series | IndraDrive Fc |
| Product Type | Compact Frequency Converter / AC Drive |
| Rated Motor Power | 2.2 kW (400 V class) |
| Input Voltage | 3-phase, 380–480 V AC |
| Input Frequency | 47–63 Hz |
| Rated Output Current | 5.5 A |
| Output | 3-phase AC, variable voltage and frequency |
| Control Modes | V/f and sensorless vector control |
| Output Frequency Range | Up to 400 Hz |
| Overload Capacity | 150% for 60 seconds; 200% for 3.5 seconds |
| Communication | RS-232 and RS-485 |
| I/O Configuration | 2 analog/digital inputs, 5 digital inputs, 1 analog output, 2 relay contact sets |
| Minimum Braking Resistance | 130 Ω |
| Protection Rating | IP20 |
| Dimensions | Approx. 73 × 226 × 153 mm (W × H × D) |
| Weight | Approx. 1.8 kg |
| Cooling | Temperature-controlled fan cooling |
| Mounting | Wall or control-cabinet mounting |
| Country of Origin | Confirm from product nameplate |
| Product Status | Confirm current lifecycle and stock status |
| Condition | Confirm actual supplied unit |
Technical Features & Specifications
Motor Speed and Torque Control
The FCS01.1E drive provides V/f and sensorless vector control for three-phase induction motors. The selected control method should match the motor characteristics and the machine’s speed and torque requirements. Correct motor data entry and parameter configuration are essential for reliable operation.
Electrical Ratings
The unit is designed for a three-phase 380–480 V AC supply and supports a 2.2 kW motor rating in the specified 400 V class. Its rated output current is 5.5 A. Motor selection should be based on rated current and operating conditions, not power rating alone.
Overload Performance
The drive supports 150% overload for 60 seconds and 200% for 3.5 seconds. These limits are intended for temporary load conditions and should not be treated as continuous operating ratings.
Communication and Control I/O
The available interfaces include RS-232 and RS-485 serial communication, two analog/digital inputs, five digital inputs, one analog output, and two relay contact sets. Confirm terminal assignments, signal types, and communication settings against the applicable wiring documentation before connecting the drive to a PLC or machine controller.
DC Bus and Braking
DC bus terminals allow use in compatible common DC bus arrangements. The specified minimum braking resistance is 130 Ω. The external braking resistor must be correctly selected for resistance, power rating, duty cycle, and installation conditions.
Application Scenarios & Pain Points
- Conveyor systems: Provides adjustable motor speed to match material transport requirements and production cycles.
- Pumping equipment: Supports variable-speed operation for process flow control.
- Industrial fans: Allows motor speed adjustment according to ventilation or process demand.
- Mixing machinery: Supports controlled motor operation during different production stages.
- Packaging equipment: Provides adjustable speed control for compatible auxiliary drives.
- General machine automation: Connects motor control functions with PLC-based systems through discrete I/O and supported serial interfaces.
First-Time Installation Checklist
- Verify that the complete model number and R911311065 material number match the machine’s electrical documentation.
- Confirm the incoming supply is three-phase 380–480 V AC and that the upstream protection is correctly rated.
- Check the motor rated voltage, current, frequency, power, and connection arrangement.
- Inspect the drive housing, terminals, cooling fan, and mounting points for damage.
- Install the drive in a clean, ventilated control cabinet with the required clearance above and below.
- Separate motor power wiring from low-level analog and communication wiring.
- Connect protective earth and follow the manufacturer’s EMC and shielding recommendations.
- Configure motor parameters, acceleration and deceleration times, control mode, and operating limits.
- Verify digital input assignments, analog signal scaling, relay functions, and serial communication settings.
- Test the motor without load where practical before commissioning the complete machine.
Daily Maintenance
- Check the drive status indicators and operating messages during routine inspections.
- Keep ventilation openings and heat-sink surfaces free of dust and debris.
- Confirm that the cooling fan operates correctly when required.
- Inspect power and control terminals for signs of overheating or looseness.
- Check motor cable insulation, grounding, and shielding connections.
- Monitor motor current and operating temperature for unusual changes.
- Review fault history and investigate recurring overcurrent, overvoltage, or thermal alarms.
- Back up drive parameters before making configuration changes.
Troubleshooting & Frequently Asked Questions
Q1: The drive does not power up. What should be checked?
A: Verify the incoming three-phase supply, upstream fuses or circuit breaker, wiring connections, and DC bus condition. Isolate the power supply before inspecting electrical terminals.
Q2: The motor does not start.
A: Check the enable signal, start command, digital input assignments, control source, fault status, and motor wiring. Confirm that the configured operating mode matches the machine control scheme.
Q3: The motor trips during acceleration.
A: Review acceleration time, load inertia, motor rated current, current limits, and the selected control mode. Confirm that the motor and mechanical load are within the drive’s rated capacity.
Q4: The drive reports an overvoltage condition during deceleration.
A: Check the deceleration ramp and regenerative energy from the load. If braking is required, verify the external braking resistor specification and wiring. The resistor must not be below the specified minimum resistance.
Q5: Can this drive communicate with a PLC?
A: The unit provides RS-232 and RS-485 interfaces. Confirm the supported protocol, communication settings, wiring, and PLC driver requirements in the applicable IndraDrive Fc documentation before integration.
Q6: Can this model replace another FCS01.1E drive?
A: Not automatically. Compare rated power, output current, voltage class, model suffix, firmware or configuration requirements, terminal arrangement, and braking specifications before approving a replacement.
Safety Precautions
- Installation and commissioning must be performed by qualified electrical personnel.
- Disconnect the power supply and observe the manufacturer’s DC bus discharge waiting time before servicing.
- Never connect or disconnect motor or power cables while the drive is energized.
- Provide protective grounding and suitable short-circuit and overcurrent protection.
- Maintain the required separation between power cables and signal or communication cables.
- Use only a braking resistor that meets the specified resistance and power requirements.
- Do not operate the drive outside its voltage, current, temperature, or environmental ratings.
- Follow the original Bosch Rexroth operating instructions and applicable electrical safety standards.
Recommended Related Models & Components
The following models belong to the same IndraDrive Fc product family or are related accessories. They are not all direct replacements for the FCS01.1E-W0011-A-04-NNBV.
- FCS01.1E-W0003-A-04-NNBV – 0.55 kW frequency converter
- FCS01.1E-W0005-A-04-NNBV – 0.75 kW frequency converter
- FCS01.1E-W0006-A-04-NNBV – 1.1 kW frequency converter
- FCS01.1E-W0008-A-04-NNBV – 1.5 kW frequency converter
- FCS01.1E-W0015-A-04-NNBV – 3.0 kW frequency converter
- FCS01.1E-W0019-A-04-NNBV – 4.0 kW frequency converter
- FCS01.1E-W0025-A-04-NNBV – 5.5 kW frequency converter
- FCS01.1E-W0032-A-04-NNBV – 7.5 kW frequency converter
- FCC01.1T-STD-NNNN – Standard operating panel
- FCC01.1T-CMF-NNNN – Comfort operating panel
- FCC01.1F-PB1-NNNN – PROFIBUS DP fieldbus module
- FCC01.1F-PB2-NNNN – PROFIBUS DP 12 MBaud fieldbus module
Verify the required accessories, fieldbus options, and compatibility with the installed drive revision before ordering.