Description
Product Description
The DEIF PPU-3 920020314.20 is a microprocessor-based Paralleling and Protection Unit designed for generator control, synchronization, and electrical protection. It belongs to DEIF’s Multi-Line 2 controller family and is widely suited to marine generator systems and industrial power-generation installations.

PPU-3 920020314.20
Key Product Specifications
- Brand: DEIF
- Model: PPU-3
- Part Number: 920020314.20
- Product Name: Paralleling and Protection Unit
- Product Type: Generator control and protection controller
- Series: DEIF Multi-Line 2
- Main Application: Marine and industrial generator control
- Generator Operation: Standalone and parallel operation
- Synchronization: Automatic generator synchronization
- Regulation Modes: Fixed frequency, fixed power, frequency droop, and load sharing
- Additional AVR Modes: Fixed voltage, fixed reactive power, fixed power factor, reactive load sharing, and voltage droop, subject to configuration
- Measurement: Three-phase voltage and current measurement
- Protection: Generator electrical protection; exact functions depend on installed options and settings
- Programming: DEIF USW-3 and M-Logic
- Communication: Serial communication; supported protocols depend on installed options
- Auxiliary Supply: 12/24 V DC nominal, 8–36 V DC operating range for the standard controller
- Measuring Voltage: 100–690 V AC range, depending on measurement configuration
- Measuring Current: 1 A or 5 A CT secondary input
- Measuring Frequency: 30–70 Hz
- Display: LCD operator interface
- Expansion: Optional engine interface card and additional operator panels
- Country of Origin: China, according to the supplied product listing; verify the individual nameplate
- Place of Manufacture: Confirm from the unit label
- Dimensions: Verify against the applicable PPU-3 mechanical drawing
- Weight: Depends on the supplied controller and display configuration; not confirmed for this exact part number
- Product Status: Legacy Multi-Line 2 equipment; availability and service status should be confirmed
- Condition: Used, according to the supplied listing
Application Scenarios and Integration
Marine generator synchronization
The PPU-3 can synchronize a diesel generator with an energized busbar by monitoring generator and busbar electrical conditions. It coordinates the synchronization process and provides control signals for the generator circuit breaker.
Parallel generator operation
When multiple generators operate in parallel, the controller supports load sharing and power regulation. This helps coordinate generator loading and maintain stable electrical operation.
Generator protection
The controller monitors electrical measurements and provides configurable protection functions. Depending on installed options, these may include overcurrent, reverse power, voltage, frequency, and other generator protection functions.
Power management systems
The PPU-3 can interface with PLC-based power management systems, SCADA equipment, and other supervisory controllers through supported communication options and I/O connections.
Engine control integration
With the optional engine interface card, the PPU-3 can provide additional engine start/stop and protection functions. The engine interface card has its own power supply and microprocessor, providing a backup engine supervision function in specified failure conditions.
Integration considerations
- Verify the generator CT ratio, secondary current rating, polarity, and phase sequence.
- Confirm the voltage transformer or direct voltage measurement arrangement.
- Check the governor and AVR control signal types before connecting analog outputs.
- Verify breaker close and trip circuit wiring and interlocks.
- Confirm the communication option before configuring Modbus, Profibus, CAN, or Ethernet interfaces.
- Check the software version and M-Logic configuration using the appropriate DEIF utility software.
- Back up all protection settings, synchronization parameters, and operating logic before replacing the controller.
Daily Maintenance
- Inspect the controller housing, LCD display, connectors, and terminal blocks.
- Verify the auxiliary DC supply and check for unstable voltage or power alarms.
- Review generator voltage, current, frequency, active power, and reactive power readings.
- Check synchronization performance and breaker closing records.
- Review generator protection alarms and event logs.
- Inspect CT and VT wiring for loose terminals, overheating, or insulation damage.
- Verify communication with the PLC, SCADA, and power management system.
- Back up controller parameters and M-Logic configurations before making changes.
- Check governor and AVR control signals during scheduled maintenance.
- Record firmware versions, hardware options, and protection setting revisions.
Troubleshooting and FAQ
Q1: The PPU-3 does not power up. What should be checked?
Check the 12/24 V DC auxiliary supply, terminal polarity, protective fuse, and power connections. Confirm that the supply remains within the specified operating range.
Q2: The generator cannot synchronize with the busbar.
Check generator and busbar voltage measurements, phase sequence, frequency difference, phase angle, and synchronization settings. Also inspect the breaker feedback and close circuit.
Q3: Load sharing is unstable between generators.
Check the load-sharing configuration, governor response, CT polarity, communication wiring, and configured control mode. Confirm that all participating generators use compatible load-sharing settings.
Q4: The controller displays incorrect voltage or current values.
Inspect the CT and VT connections, measurement wiring, transformer ratios, and phase assignments. Incorrect measurement scaling can affect synchronization and protection functions.
Q5: Can the PPU-3 communicate with a PLC or SCADA system?
Yes. DEIF identifies serial communication for PLC and SCADA integration. The exact protocol and interface depend on the installed communication options. Verify the hardware configuration before selecting communication settings.
Q6: Can the PPU-3 replace a GPU-3?
Not as a direct drop-in replacement in every application. The PPU-3 includes paralleling and synchronization functions, while the GPU-3 is primarily a generator protection unit. Compare application requirements, hardware options, wiring, and software configuration.
Q7: What software is used to configure the PPU-3?
DEIF Multi-Line 2 Utility Software version 3 (USW-3) is used for configuration and parameter management. M-Logic provides programmable logic functionality for customized control sequences.
Safety Precautions
- Disconnect and isolate the auxiliary power supply before installation or removal.
- Follow the vessel’s electrical lockout/tagout procedures.
- Treat CT secondary circuits as hazardous and never open an energized CT circuit without an approved shorting procedure.
- Verify voltage measurement wiring and phase sequence before commissioning.
- Confirm breaker close and trip circuits before enabling automatic synchronization.
- Do not modify generator protection thresholds without approval from the responsible electrical engineer.
- Test synchronization and load-sharing functions under controlled commissioning conditions.
- Confirm emergency shutdown and generator protection functions before returning the equipment to service.
Recommended Related DEIF Models
The following models and components belong to related DEIF generator control, protection, and power management product families. They are not all direct replacements for PPU-3 920020314.20.
- DEIF PPU-3 – Paralleling and Protection Unit
- DEIF GPU-3 – Generator Protection Unit
- DEIF GPC-3 – Generator Paralleling Controller
- DEIF GPU-3 Hydro – Generator Protection Unit
- DEIF AGC-4 – Advanced Genset Controller
- DEIF AGC-4 Mk II – Advanced Genset Controller
- DEIF AGC 150 – Advanced Genset Controller
- DEIF AGC 200 – Automatic Genset Controller
- DEIF PPM 300 – Power and Protection Management
- DEIF ASC – Automatic Sustainable Controller
- DEIF AOP-1 – Additional Operator Panel
- DEIF AOP-2 – Additional Operator Panel
- DEIF PCM 4 – Power Control Module
- DEIF MVR-200 – Voltage Regulator
- DEIF USW-3 – Multi-Line 2 Utility Software
Inspection and Testing Recommendations
Before dispatch, verify the complete part number, serial number, hardware revision, software version, and installed option cards. Inspect the display, connectors, terminal blocks, and housing for physical damage.
Where a suitable test setup is available, perform controlled checks of auxiliary power, three-phase measurement inputs, synchronization logic, generator protection functions, digital and analog I/O, communication, and event recording.
For a replacement installation, compare the original controller’s parameter file, CT/VT ratios, governor and AVR interfaces, breaker logic, and protection settings. A successful power-up test alone does not establish complete functional compatibility.
Ordering Note: DEIF PPU-3 920020314.20 is a configuration-specific generator paralleling and protection controller. Confirm the exact hardware options, software revision, and terminal arrangement before ordering or installing.