Description
Product Description
The EPRO CON011 (9200-00001) is a field-mounted eddy current signal converter designed for use with EPRO eddy current measurement systems. It receives the signal from a compatible proximity probe, processes the measurement signal, and provides a proportional voltage output for machinery monitoring equipment.
Unlike cabinet-mounted monitoring modules, the CON011 is designed for installation close to the monitored machine. Its sealed metal enclosure and LEMO sensor connection support field installation in industrial environments. Typical applications include shaft displacement, relative shaft vibration, and other non-contact measurements on rotating machinery.
The CON011 is suitable for machinery protection and condition-monitoring installations involving turbines, compressors, pumps, and other rotating equipment. Correct operation depends on matching the converter to the probe type, measurement range, cable arrangement, and monitoring system input.

CON011 9200-00001
Key Technical Specifications
- Brand: EPRO
- Model: CON011
- Part Number: 9200-00001
- Product Type: Eddy Current Signal Converter
- Product Series: EPRO Machinery Health Monitoring
- Measurement Technology: Eddy Current Proximity Measurement
- Signal Output Range: -4 to -20 V
- Reference Voltage: -12 V
- Frequency Range: 0 to 20 kHz
- Rise Time: Less than 15 μs
- Sensor Connection: LEMO connector
- Protection Rating: IP67
- Operating Temperature: -30 to +100°C
- Mounting: Field-mounted directly on the monitored equipment
- Country of Origin: Verify against the product nameplate and shipping documentation
- Product Status: Verify current production and availability status
- Dimensions and Weight: Confirm against the exact hardware revision
Key Features
- Converts eddy current probe signals into proportional voltage signals for monitoring equipment.
- Supports high-frequency measurement signals up to 20 kHz.
- Fast response time for monitoring dynamic shaft movement.
- Field-mountable housing reduces the need to install the converter inside a control cabinet.
- IP67 enclosure protection for suitable industrial field installations.
- LEMO connector arrangement supports secure sensor connection.
- Designed for integration into compatible EPRO machinery monitoring measurement chains.
Application Scenarios and Pain Points
Steam and gas turbines: Supports shaft vibration and displacement measurement used in turbine condition monitoring.
Industrial compressors: Provides measurement signals for monitoring shaft movement and identifying abnormal mechanical conditions.
Pumps and rotating machinery: Supports non-contact displacement measurement in machinery monitoring installations.
Power generation facilities: Can be used as part of an existing EPRO measurement chain where compatible probes and monitoring equipment are installed.
Petrochemical plants: Field-mounted installation is useful where machinery monitoring components need to be positioned close to the measurement point.
Installation and Commissioning
- Confirm that the converter part number and hardware configuration match the existing measurement chain.
- Check the probe model, extension cable, connector arrangement, and required measurement range.
- Mount the converter securely using the specified mounting hardware and an appropriate installation location.
- Connect the eddy current probe through the designated LEMO connector.
- Wire the power supply and signal output according to the applicable EPRO installation documentation.
- Verify supply polarity, output range, grounding, and cable routing before energizing the system.
- Check the output voltage at the connected monitoring equipment and compare it with the expected probe gap and calibration data.
- Perform a functional test and confirm that alarm and trip thresholds remain consistent with the approved machinery protection settings.
Do not assume that a CON011 can replace a CON021 or another converter solely because the sensor family appears similar. Confirm the required installation type, electrical configuration, and measurement range.
Daily Maintenance
- Inspect the converter enclosure for cracks, corrosion, loose mounting hardware, or mechanical damage.
- Check the LEMO connector for contamination, moisture, and damaged contacts.
- Inspect sensor and output cables for abrasion, excessive bending, or loose terminations.
- Monitor output stability and compare readings with historical machinery measurements.
- Check for abnormal signal drift or intermittent measurement loss.
- Keep the installation environment within the specified temperature range.
- Record maintenance work and measurement-chain calibration results.
Troubleshooting and FAQ
Q1: What is the main function of the EPRO CON011?
It converts signals from compatible eddy current probes into proportional voltage signals for machinery monitoring equipment.
Q2: Is the CON011 a vibration monitoring rack module?
No. It is a field-mounted signal converter, not a rack-mounted monitoring card or communication module.
Q3: What is its output range?
The published standard output range is -4 to -20 V, with a -12 V reference voltage. Confirm the required configuration before connecting it to a monitoring input.
Q4: Can it be used with every EPRO PR642x probe?
Compatibility must be checked against the exact probe model and measurement range. Do not assume every probe variant has the same electrical and calibration requirements.
Q5: What should be checked if the monitoring system shows no signal?
Inspect the power supply, probe connection, LEMO connector, cable continuity, converter wiring, and monitoring-system input configuration. Use the applicable EPRO troubleshooting procedure to isolate the fault.
Q6: Can the CON011 be installed inside a control cabinet?
It is designed for field mounting close to the monitored equipment. Follow the installation documentation and environmental requirements for the intended application.
Safety Precautions
- Isolate the relevant equipment and follow site lockout/tagout procedures before installation or maintenance.
- Verify the supply voltage and polarity before connecting the converter.
- Never connect the voltage output to a current-input terminal without an approved interface.
- Do not modify probe cables or connector wiring without the correct wiring documentation.
- Confirm hazardous-area approval requirements before installation in classified locations.
- Machinery protection and trip circuits must be tested under an approved commissioning procedure.
- Do not bypass vibration or displacement protection functions to compensate for an incorrect measurement signal.
Recommended Related Models and Components
The following are related EPRO measurement-chain components and monitoring references. They are not all direct replacements for the CON011.
- EPRO PR6422 Eddy Current Sensor
- EPRO PR6423 Eddy Current Sensor
- EPRO PR6424 Eddy Current Sensor
- EPRO PR6425 Eddy Current Sensor
- EPRO PR6426 Eddy Current Sensor
- EPRO CON021 Eddy Current Signal Converter
- EPRO CON011/91x Extended-Range Converter Variant
- EPRO PR6423 Extension Cable
- EPRO MMS6110 Monitoring Module
- EPRO MMS6120 Temperature Monitoring Module
- EPRO MMS6140 Monitoring Module
- EPRO MMS6210 Monitoring Module
- EPRO MMS6823 Displacement Monitoring Module
- EPRO A6110 Shaft Vibration Monitor
- EPRO MMS 6000 Machinery Monitoring System
Inspection and Quality Control
Before shipment or installation, verify the model and part number on the product label. Inspect the enclosure, mounting points, LEMO connector, and electrical terminals for damage. Where suitable test equipment is available, check the converter’s supply requirements, output response, and signal stability using a compatible probe or approved simulator. Record the inspection results and confirm that the unit matches the required measurement-chain configuration.