Sale!

GE | DS200TCTGG1AFF | Mark V Simplex Trip Board

Original price was: $10,000.00.Current price is: $999.00.

Product NO: DS200TCTGG1AFF

Brand:GE

Delivery time:  In stock

Product status:   Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

Product Description

The GE DS200TCTGG1AFF is a TCTG Simplex Trip Board designed for the GE Speedtronic Mark V gas turbine control system.

The board performs turbine trip and relay-control functions within the Mark V protection architecture. It supports relay operations associated with turbine shutdown, fuel shutoff, and synchronization functions. These functions are essential to the coordinated operation of turbine control and protection circuits.

The DS200TCTGG1AFF features 21 plug-in relays, three 50-pin connectors, and two 12-pin connectors. Its relay arrangement supports maintenance and replacement of individual relay components when permitted by the equipment maintenance procedure.

This board is intended for compatible Mark V installations. It is not a general-purpose PLC relay output module. Replacement requires verification of the complete catalog number, revision, relay configuration, connector wiring, and installed Mark V architecture.

GE DS200TCTGG1AFF

GE DS200TCTGG1AFF

Key Technical Specifications

  • Brand: General Electric (GE)
  • Model: DS200TCTGG1AFF
  • Functional Acronym: TCTG
  • Product Name: Mark V Simplex Trip Board
  • Product Series: Speedtronic Mark V
  • Product Type: Turbine Trip and Relay Control Board
  • Primary Function: Turbine trip relay control and synchronization-related relay functions
  • Relay Quantity: 21 plug-in relays
  • Relay Identification: K1–K21
  • 50-Pin Connectors: 3 (JLY, JLX, JLZ)
  • 12-Pin Connectors: 2 (JN, JM)
  • Relay Mounting: Plug-in connectors with retaining metal straps
  • PCB Coating: Normal coating
  • Functional Revision 1: A
  • Functional Revision 2: F
  • Artwork Revision: F
  • System Compatibility: GE Speedtronic Mark V, subject to configuration verification
  • Power Requirements: Verify from the applicable Mark V wiring documentation
  • Dimensions: Verify against the physical board and mechanical drawing
  • Weight: Verify from the individual unit
  • Country of Origin: Verify from the product label
  • Product Status: Legacy spare part; current manufacturer lifecycle status requires confirmation

 

Key Features

  • Dedicated turbine trip control functionality for GE Mark V systems.
  • 21 plug-in relays for designated trip and control circuits.
  • Three 50-pin and two 12-pin connectors.
  • Relay identification using K-series designations.
  • Retaining straps secure plug-in relays in their connectors.
  • Supports turbine shutdown and protection-related control functions.
  • Includes synchronization-related relay functions in the Mark V architecture.
  • Suitable for maintenance and replacement of compatible legacy turbine-control installations.

 

Application Scenarios and Pain Points

Gas turbine protection: Supports relay functions involved in turbine trip and fuel shutoff operations. Correct relay operation is essential to the protective shutdown sequence.

Steam turbine control: Can be used in compatible Mark V installations where the TCTG board is part of the configured trip architecture.

Power generation facilities: Supports turbine protection and control circuits in generating stations.

Turbine synchronization: The TCTG board participates in synchronization-related relay functions within the Mark V control architecture.

Legacy control-system maintenance: Replacing a faulty board with the correct revision helps preserve the original wiring and protection design.

Trip circuit troubleshooting: Relay and connector inspections can help maintenance teams investigate abnormal trip indications, failed relay operation, and associated control-circuit faults.

 

Installation and Commissioning

  1. Follow the turbine shutdown and maintenance procedure approved for the installation.
  2. Isolate all relevant electrical supplies and verify the absence of hazardous voltage.
  3. Record the complete board number and all functional and artwork revision markings.
  4. Photograph the original board, relay positions, connector locations, and wiring.
  5. Confirm the replacement model is DS200TCTGG1AFF.
  6. Compare the relay arrangement and connector configuration with the original board.
  7. Inspect the PCB, plug-in relays, retaining straps, and connectors for damage.
  8. Remove and install the board according to the GE Mark V maintenance instructions.
  9. Reconnect all cables using the original connector references and wiring diagrams.
  10. Verify relay positions and hardware jumper settings against the approved system documentation.
  11. Perform the prescribed continuity and functional checks.
  12. Verify trip-circuit indications and synchronization-related relay functions using an approved test procedure.
  13. Document the replacement and commissioning results before returning the turbine to service.

Turbine trip circuits are safety-critical. Do not bypass, force, or casually energize trip relays during testing. Functional testing must follow the plant’s approved protection-system procedure.

 

Daily Maintenance

  • Monitor turbine trip and protection-system alarms.
  • Review relay status and abnormal trip indications.
  • Inspect accessible connectors for looseness or contamination.
  • Check relay retaining straps and plug-in relay seating during scheduled maintenance.
  • Inspect the PCB for discoloration, corrosion, or heat damage.
  • Verify that replacement relays match the specified type and electrical ratings.
  • Maintain records of board revisions and relay replacements.
  • Keep the control cabinet clean and within the specified environmental limits.

 

Troubleshooting and FAQ

Q1: What is the GE DS200TCTGG1AFF?

It is a GE Mark V TCTG Simplex Trip Board used for turbine trip and relay-control functions.

Q2: How many relays are installed on this board?

The documented configuration contains 21 plug-in relays, identified by K-series designations.

Q3: What connectors does the DS200TCTGG1AFF use?

It has three 50-pin connectors identified as JLY, JLX, and JLZ, along with two 12-pin connectors identified as JN and JM.

Q4: Does the TCTG board control turbine fuel shutoff functions?

The TCTG board participates in the Mark V turbine trip architecture, including relay functions associated with fuel shutoff. The exact circuit responsibilities depend on the installed Mark V configuration.

Q5: Does the board also support synchronization functions?

Yes. The TCTG board is associated with synchronization-related relay functions in the Mark V architecture.

Q6: Can the DS200TCTGG1AFF be used in a Mark VI or Mark VIe system?

It is designed for Mark V. Direct use in Mark VI or Mark VIe systems should not be assumed because the hardware and protection architectures differ.

Q7: Can a DS200TCTGG1A replace the DS200TCTGG1AFF?

The base model is related, but the complete suffix identifies a specific configuration and revision. Confirm interchangeability through the applicable GE documentation and approved spare-parts list.

Q8: What should be checked if a trip relay does not operate correctly?

Check the relay itself, socket contacts, retaining hardware, associated control signals, wiring, and upstream protection logic. Do not assume that the TCTG board is the source of every trip-circuit fault.

 

Safety Precautions

  • Only qualified turbine-control and protection-system personnel should service this board.
  • Isolate relevant power supplies before removing or installing the board.
  • Observe electrostatic discharge precautions.
  • Never bypass turbine trip or emergency shutdown circuits.
  • Do not change relay positions or wiring without approved drawings.
  • Verify relay ratings and contact configurations before replacement.
  • Do not perform live relay replacement unless explicitly permitted by the equipment documentation.
  • Complete approved protection-system tests before returning the turbine to operation.

 

Recommended Related GE Models and Components

The following are related GE Mark V control and protection components for maintenance research. They are not confirmed direct replacements for DS200TCTGG1AFF.

  1. GE DS200TCTGG1A – TCTG Turbine Trip Board
  2. GE DS200TCEAG1B – Mark V Emergency Overspeed Protection Board
  3. GE DS200TCEBG1B – Mark V Protection and Control Board
  4. GE DS200TCQAG1 – Mark V Analog I/O Board
  5. GE DS200TCQCG1 – Mark V Analog Control Board
  6. GE DS200TCCAG1 – Mark V Common Data Processor Board
  7. GE DS200TCCBG1 – Mark V Common Data Processor Board
  8. GE DS200SDCCG1 – Mark V Drive Control Board
  9. GE DS200TCPDG1 – Mark V Power Distribution Board
  10. GE DS200TCPSG1 – Mark V Power Supply Board
  11. GE DS200PTBAG1 – Mark V Protection Core Terminal Board
  12. GE DS200DTBCG1 – Mark V Contact Input/Output Terminal Board
  13. GE DS200DTBDG1 – Mark V Contact Input/Output Terminal Board
  14. GE DS200TCDAH1 – Mark V Digital I/O Board
  15. GE DS200SLCCG1 – Mark V LAN Communication Board

Verify complete part numbers, revision suffixes, and core assignments before ordering or substituting related components.

 

Inspection and Quality Control

  • Part identification: Confirm DS200TCTGG1AFF on the board label.
  • Revision verification: Record functional revisions A and F and artwork revision F.
  • Visual inspection: Check PCB tracks, components, connectors, and relay sockets.
  • Relay inspection: Confirm the presence and condition of the 21 plug-in relays.
  • Connector inspection: Inspect all three 50-pin and two 12-pin connector positions.
  • Mechanical inspection: Check retaining straps and relay seating.
  • Functional testing: Where suitable Mark V test equipment is available, verify relay operation using an approved test procedure.
  • Protection testing: Perform required trip-circuit verification under controlled conditions.
  • Final documentation: Record serial or batch information, photographs, inspection results, and functional test status.

The actual condition, relay configuration, and functional test results should be confirmed for each individual unit before shipment.

about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.