Description
Product Description
The GE Multilin 350-E-P1-S1-H-S-E-C-N-2E-D-H is a microprocessor-based feeder protection relay designed for electrical distribution systems. It provides protection, monitoring, metering, and breaker control functions for industrial and utility power networks.

350-E-P1-S1-H-S-E-C-N-2E-D-H
⚙️ Product Parameters
- Brand: GE Multilin
- Model: 350-E-P1-S1-H-S-E-C-N-2E-D-H
- Product Name: 350 Feeder Protection System
- Product Type: Microprocessor-Based Feeder Protection Relay
- Product Series: Multilin 350
- Phase Current Input: P1 designation; 1 A phase CT input configuration
- Ground Current Configuration: S1 designation; verify the exact input assignment against the order-code documentation
- Power Supply Code: H; high-voltage supply configuration
- Power Supply Range: 110–250 VDC / 110–230 VAC, subject to nameplate verification
- Protection Functions: Phase, ground, and neutral overcurrent protection, subject to ordered configuration
- Additional Functions: Voltage, frequency, directional protection, breaker failure, and autoreclose functions, as supported by configuration
- Control Functions: Breaker trip and close control, programmable logic, and interlocking
- Event Recording: Supported
- Communication: Verify installed communication options and protocol configuration
- Mounting: Verify draw-out or fixed configuration from the actual unit
- Conformal Coating: Confirm from the complete hardware specification
- Place of Manufacture: Not confirmed for this individual unit
- Country of Origin: Verify the nameplate
- Product Condition: Confirm against the actual item’s label and seller description
- Dimensions: Refer to the GE Multilin 350 mechanical installation specifications
- Weight: Verify against the exact hardware configuration
- Discontinued Status: Confirm with GE Vernova
🏭 Application Scenarios and Operating Benefits
Industrial feeder protection
The 350 relay monitors electrical feeder conditions and operates protective functions when configured fault thresholds are exceeded. It helps protect cables, switchgear, and downstream equipment.
Transformer protection applications
The relay can provide feeder-side overcurrent and related protection for transformer installations. Protection coordination must be engineered according to transformer ratings and system fault levels.
Motor and generator backup protection
Its available overcurrent and thermal protection functions can support selected motor and generator applications. The actual protection scheme must be checked against the equipment’s protection requirements.
Circuit breaker control
The relay supports breaker-related functions such as trip, close, breaker failure monitoring, and autoreclose, depending on the ordered configuration and programmed logic.
Power system event analysis
Event recording and metering information help maintenance engineers investigate disturbances, review fault conditions, and evaluate relay operation.
🔧 Daily Maintenance and Care
- Inspect the relay front panel, display, keypad, housing, and connectors for physical damage.
- Verify auxiliary power supply voltage and check for abnormal power or self-diagnostic alarms.
- Review active targets, event records, and fault indications during routine inspections.
- Inspect CT and VT secondary wiring for loose terminals, damaged insulation, or incorrect connections.
- Check trip and close circuit wiring, breaker auxiliary contacts, and output relay connections.
- Review protection settings and compare them with the approved coordination study.
- Verify communication status and remote monitoring connections where installed.
- Perform scheduled secondary-injection testing using approved test equipment and procedures.
- Back up relay settings, logic configurations, and event records before maintenance or replacement.
- Record firmware revision, serial number, order code, and configuration changes in the maintenance log.
🛠️ Troubleshooting and Common Problems
Q1: The relay does not power up.
Check the auxiliary supply, protective fuse, wiring polarity, and terminal connections. Verify that the supply matches the H power-supply configuration shown on the nameplate.
Q2: The relay displays incorrect phase current readings.
Check CT ratios, secondary wiring, phase assignments, polarity, and configured current ratings. Use approved test equipment to verify the secondary current signals.
Q3: The relay trips the circuit breaker unexpectedly.
Review the event record, fault targets, protection settings, and measured electrical quantities. Check for incorrect CT/VT wiring, unsuitable pickup values, or coordination problems before returning the feeder to service.
Q4: The relay does not issue a trip command during a simulated fault.
Check the enabled protection elements, pickup and delay settings, output relay assignment, trip wiring, and test configuration. Confirm that the test method exercises the intended protection element.
Q5: Communication with the control system is unavailable.
Inspect the communication cable, interface hardware, network configuration, protocol settings, and device address. Confirm which communication options are installed in the specific relay.
Q6: Can another Multilin 350 relay replace this model?
Not automatically. The replacement must match the current input ratings, auxiliary power supply, ground-current configuration, I/O arrangement, protection options, communication hardware, and firmware requirements.
⚠️ Safety Precautions
- Isolate the protected circuit and auxiliary supplies according to the approved electrical safety procedure before servicing the relay.
- Never open-circuit an energized current transformer secondary. CT circuits can develop hazardous voltages.
- Follow approved procedures when isolating voltage transformer circuits.
- Verify the relay’s rated auxiliary supply before applying power.
- Do not change protection settings without authorization and an approved protection coordination study.
- Test trip and close circuits carefully to prevent unintended circuit breaker operation.
- Use suitable secondary-injection test equipment and qualified personnel.
- Confirm all protection functions and breaker interfaces after installation or replacement.
- Do not return the protected feeder to service until commissioning checks are complete.
📦 Recommended GE Multilin Models and Related Products
The following GE Multilin products are related protection and control devices for power distribution and industrial electrical systems. They are not confirmed direct replacements for the 350 relay.
- GE Multilin 350 Feeder Protection System
- GE Multilin 850 Feeder Protection System
- GE Multilin 750 Feeder Protection Relay
- GE Multilin 760 Feeder Protection Relay
- GE Multilin 469 Motor Management Relay
- GE Multilin 369 Motor Protection Relay
- GE Multilin 339 Motor Protection Relay
- GE Multilin 489 Generator Protection Relay
- GE Multilin 745 Transformer Protection Relay
- GE Multilin 345 Transformer Protection Relay
- GE Multilin 845 Transformer Protection System
- GE Multilin 869 Motor Protection System
- GE Multilin 850 Line Protection System
- GE Multilin 9650 Power Quality Meter
- GE Multilin 8 Series Protection Relays
Compatibility Note: The GE Multilin 350 order code defines important hardware and functional options. Before purchasing a replacement, compare the complete order code, CT input ratings, ground-current input arrangement, auxiliary supply, I/O configuration, communication options, firmware, and protection settings. Similar product-family names do not guarantee interchangeability.