Description
Product Description
The SST-PFB-CLX is a PROFIBUS DP communication scanner designed for Allen-Bradley ControlLogix PLC systems using the 1756 chassis platform. Manufactured by SST (Woodhead/Molex), it enables communication between a ControlLogix processor and remote PROFIBUS DP devices, including distributed I/O stations, motor drives, valve controllers, and other field equipment.
Operating as a PROFIBUS DP Master, the module manages cyclic data exchange with connected slave devices and maps their input and output data into the ControlLogix controller’s I/O data arrays. It also supports DPV1 acyclic communication services and can operate as a DPV0 Slave under supported configurations.
The SST-PFB-CLX occupies one slot in a 1756 ControlLogix chassis and includes an RS-485 PROFIBUS interface and an RS-232 configuration port. Its onboard Flash memory stores the PROFIBUS configuration, allowing the scanner to retain its network setup after power cycling.
For industrial automation engineers maintaining legacy ControlLogix installations, the SST-PFB-CLX provides a practical interface between Rockwell Automation control systems and PROFIBUS-based field networks.

SST-PFB-CLX
Key Technical Specifications
- Brand: SST / Woodhead / Molex
- Model: SST-PFB-CLX
- Product Type: PROFIBUS DP Scanner and Communication Module
- Application Platform: Allen-Bradley ControlLogix
- Chassis Compatibility: 1756 ControlLogix chassis
- Installation: Single-slot module
- PROFIBUS Interface: RS-485
- PROFIBUS Connector: 9-pin D-sub
- Configuration Interface: RS-232 serial port
- PROFIBUS Operating Modes: DP Master and DPV0 Slave
- DPV1 Support: Class 1 and Class 2 services
- Supported Baud Rates: 9.6 kbit/s to 12 Mbit/s
- Maximum Slave Capacity: 125 PROFIBUS DP slaves
- Maximum Input Data per Slave: 122 words
- Maximum Output Data per Slave: 122 words
- Master I/O Capacity: Up to 1,984 bytes input and 1,968 bytes output across four I/O pages
- Configuration Storage: Onboard Flash memory
- Configuration Software: SST PROFIBUS Configuration Tool
- Maximum Scanner Modules: Up to 8 per ControlLogix rack
- Installation Position: Any suitable slot in a local or remote ControlLogix chassis
- Supply: Powered through the ControlLogix backplane
- Operating Temperature: Verify against the exact hardware revision and manufacturer documentation
Key Features
- Connects ControlLogix processors to PROFIBUS DP field networks.
- Supports PROFIBUS DP Master operation for remote I/O scanning.
- Supports DPV1 Class 1 and Class 2 acyclic communication services.
- Can operate as a DPV0 Slave in supported configurations.
- Handles up to 125 PROFIBUS slave devices.
- Supports standard PROFIBUS baud rates up to 12 Mbit/s.
- Stores network configuration in onboard Flash memory.
- Provides RS-232 access for configuration and maintenance.
- Supports installation in local or remote 1756 chassis.
- Allows multiple scanners to be installed in one ControlLogix rack.
Application Scenarios and Pain Points
ControlLogix and PROFIBUS Integration: Connects a Rockwell Automation ControlLogix processor to existing PROFIBUS DP networks without replacing all installed field devices.
Distributed Remote I/O: Exchanges process signals with PROFIBUS remote I/O stations and transfers the resulting data into the ControlLogix application.
Variable Frequency Drive Communication: Enables communication with compatible PROFIBUS-connected drives for control commands, operating status, and process feedback.
Legacy Plant Modernization: Helps retain existing PROFIBUS infrastructure when upgrading or maintaining the central ControlLogix control system.
Multi-Network Control Architecture: Multiple SST-PFB-CLX scanners can be installed in a suitable ControlLogix rack to manage separate PROFIBUS networks.
Industrial Equipment Integration: Supports communication with third-party PROFIBUS DP devices, reducing the need for separate protocol-conversion equipment.
Installation and Commissioning
- Confirm the module model and hardware revision before installation.
- Verify that the target chassis is an Allen-Bradley 1756 ControlLogix system.
- Check the ControlLogix processor, chassis configuration, and available module slots.
- Install the SST-PFB-CLX in an approved slot according to the hardware installation instructions.
- Connect the PROFIBUS network through the 9-pin D-sub connector using suitable shielded PROFIBUS cable.
- Import the required GSD files for connected PROFIBUS slave devices into the SST configuration software.
- Configure slave addresses, baud rate, device parameters, and input/output data sizes.
- Download the PROFIBUS configuration to the scanner through the supported configuration interface.
- Map the scanner’s input and output data into the ControlLogix controller’s I/O data structures.
- Verify slave communication, network diagnostics, and data updates in the PLC application.
- Test device control and feedback functions before returning the system to normal operation.
Daily Maintenance
- Check the scanner’s status indicators and network diagnostics.
- Monitor PROFIBUS communication errors and slave availability.
- Inspect the 9-pin D-sub connector for looseness or damage.
- Check PROFIBUS cable shielding, termination, and grounding arrangements.
- Review slave configuration and address assignments after field-device changes.
- Maintain backups of the scanner configuration and GSD files.
- Monitor the ControlLogix chassis for module faults and backplane communication errors.
- Record hardware revisions and configuration changes for maintenance traceability.
Troubleshooting and FAQ
Q1: What is the main function of the SST-PFB-CLX?
It acts as a PROFIBUS DP scanner for ControlLogix systems, enabling communication between a ControlLogix processor and PROFIBUS DP field devices.
Q2: How many PROFIBUS slave devices can it support?
The manufacturer’s reference guide specifies support for up to 125 slave devices.
Q3: Which communication speeds are supported?
It supports standard PROFIBUS baud rates from 9.6 kbit/s to 12 Mbit/s.
Q4: Does the module support DPV1?
Yes. It supports DPV1 Class 1 and Class 2 services, including specified acyclic read, write, and connection-management functions.
Q5: Can the SST-PFB-CLX operate as a PROFIBUS Slave?
Yes. The reference guide documents DPV0 Slave operation. Simultaneous Master and Slave operation is also supported under specified conditions, with the maximum baud rate limited to 1.5 Mbit/s.
Q6: Which configuration software is required?
The SST PROFIBUS Configuration Tool is used to configure the scanner, define the PROFIBUS network, and store the configuration in the module’s Flash memory.
Q7: Can multiple SST-PFB-CLX modules be installed in one chassis?
Yes. The reference guide specifies up to eight scanners in a ControlLogix rack, subject to chassis and system configuration requirements.
Q8: Is the SST-PFB-CLX compatible with CompactLogix?
It is designed for the 1756 ControlLogix chassis. Do not assume compatibility with CompactLogix or other PLC platforms.
Q9: What should be checked if PROFIBUS communication fails?
Check the RS-485 wiring, bus termination, slave addresses, baud rate, GSD configuration, scanner diagnostics, and ControlLogix I/O mapping. Confirm that the configuration stored in the scanner matches the connected network.
Safety Precautions
- Installation and maintenance must be performed by qualified industrial automation personnel.
- Follow the ControlLogix chassis manufacturer’s procedures for module installation and removal.
- Confirm the system is in a safe operating state before disconnecting the scanner.
- Use suitable PROFIBUS cable, connectors, shielding, and termination.
- Avoid incorrect bus termination or unsupported network topology changes.
- Back up the scanner configuration before making modifications.
- Do not alter PLC data mapping or field-device parameters without reviewing the control application.
- Verify communication and interlocking functions before returning equipment to service.
Recommended Related Models and Components
The following products are related to ControlLogix and PROFIBUS integration. They are not all direct replacements for the SST-PFB-CLX.
- SST-PB3-CLX-RLL – SST PROFIBUS scanner product reference
- 1756-L55 – Allen-Bradley ControlLogix Controller
- 1756-L61 – Allen-Bradley ControlLogix Controller
- 1756-L62 – Allen-Bradley ControlLogix Controller
- 1756-L63 – Allen-Bradley ControlLogix Controller
- 1756-L71 – ControlLogix Controller
- 1756-L72 – ControlLogix Controller
- 1756-A4 – ControlLogix Four-Slot Chassis
- 1756-A7 – ControlLogix Seven-Slot Chassis
- 1756-A10 – ControlLogix Ten-Slot Chassis
- 1756-A13 – ControlLogix Thirteen-Slot Chassis
- 1756-A17 – ControlLogix Seventeen-Slot Chassis
- 1756-PB75 – ControlLogix DC Power Supply
- MVI56-PDPMV1 – ProSoft PROFIBUS DP Master Communication Module
- 1756-ENBT – ControlLogix EtherNet/IP Communication Module
Confirm processor compatibility, firmware, configuration software, and network architecture before selecting any related component as a replacement.
Inspection and Quality Control
Before installation, verify the SST-PFB-CLX model label, hardware revision, connector condition, and physical integrity. Inspect the RS-485 PROFIBUS port, RS-232 configuration port, and backplane connector for damage or corrosion.
Functional testing should be performed in a compatible 1756 ControlLogix chassis with a configured PROFIBUS network. Check module recognition, configuration download, slave communication, cyclic I/O exchange, and applicable DPV1 services.
Record the module identification, hardware revision, configuration version, connected slave devices, and test results. Confirm the actual unit condition and included accessories before purchase or installation.