Sale!

YOKOGAWA | AVR10D-Q22021 | Duplexed V Net Router

Original price was: $10,000.00.Current price is: $666.00.

Product NO:AVR10D-Q22021

Brand:YOKOGAWA

Delivery time:  In stock

Product status:   Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

Product Description

The Yokogawa AVR10D-Q22021 is a Duplexed V net Router designed for communication between Yokogawa CENTUM distributed control system networks. Although it is often advertised as a complete PLC module, its primary function is network routing and communication management rather than general-purpose PLC logic processing.

The AVR10D provides a communication path between different CENTUM network domains, helping connect control stations and system components across V net and compatible network configurations. The Q22021 suffix identifies a dual-redundant V net configuration with dual power supplies and a 220–240 V AC power supply arrangement.

AVR10D-Q22021

AVR10D-Q22021

Key Product Specifications

  • Brand: Yokogawa
  • Model: AVR10D
  • Full Model: AVR10D-Q22021
  • Product Name: Duplexed V Net Router
  • Product Type: Industrial control system network communication unit
  • Series: Yokogawa CENTUM communication equipment
  • Configuration: Dual-redundant V net, dual power supply
  • Suffix Code: Q2 / 2 / 2 / 1
  • Network Type: V net, 10BASE-2 coaxial network
  • Power Supply: 220–240 V AC
  • Frequency: 50/60 Hz
  • Power Consumption: Approximately 110 VA combined, according to the identified configuration
  • Redundancy: Dual communication and dual power supply architecture
  • Main Assembly Number: C2GC17255C
  • Communication Components: Verify installed VC401 and VI451 modules against the rack labels
  • Installation: 19-inch rack mounting
  • Mounting: Four M5 screws
  • Dimensions: Approximately 482.6 × 169 × 150.6 mm, subject to the applicable installation drawing
  • Weight: Approximately 5.36 kg, subject to the supplied assembly configuration
  • Place of Manufacture: Singapore, according to the identified product listing
  • Country of Origin: Singapore, verify on the individual nameplate
  • Product Status: Legacy CENTUM communication equipment; availability should be confirmed
  • Condition: Used, according to the supplied listing

 

Application Scenarios and Integration

CENTUM distributed control system networking

The AVR10D connects compatible Yokogawa control system network domains. It is used where communication between different CENTUM system segments is required.

Redundant control network architecture

The Q22021 configuration supports dual-redundant V net communication and dual power supplies. This arrangement helps maintain communication availability if one redundant path or power supply becomes unavailable, provided the complete system is correctly configured.

Industrial process control

The router can be used in power generation, chemical processing, oil and gas, marine automation, and other installations using compatible Yokogawa CENTUM systems.

Legacy system maintenance

The AVR10D-Q22021 is suitable for replacing an existing unit where the original V net topology, network addressing, and redundant communication design must be retained.

Integration considerations

  • Confirm that the existing network uses the correct V net configuration rather than assuming compatibility with Vnet/IP.
  • Check the coaxial network connections, termination, cable condition, and network topology.
  • Verify the installed VC401 and VI451 module types and hardware revisions.
  • Confirm that both power supply inputs match the 220–240 V AC configuration.
  • Check network redundancy settings and communication status before returning the system to operation.
  • Install the router in a keyed metallic cabinet as required by Yokogawa’s EMC installation guidance.

 

Daily Maintenance

  1. Inspect the rack enclosure, mounting screws, and connectors for physical damage.
  2. Check both AC power supply paths and verify that the redundant supply arrangement is functioning correctly.
  3. Review network status indicators and communication alarms.
  4. Inspect coaxial cables, BNC connectors, and network termination components.
  5. Check the condition of the communication and coupler modules.
  6. Keep the cabinet clean and maintain adequate ventilation.
  7. Record module revisions, network configuration, and maintenance history.
  8. Back up relevant CENTUM network configuration information before replacing communication hardware.

 

Troubleshooting and FAQ

Q1: The AVR10D does not power up.

Check the incoming 220–240 V AC supply, protective devices, power connections, and both power supply modules. Confirm that the supply arrangement matches the Q22021 configuration.

Q2: The router reports a communication fault.

Inspect the coaxial network cable, BNC connectors, termination, communication modules, and network configuration. Check whether the fault affects one redundant path or both paths.

Q3: Redundant communication is not operating correctly.

Verify both network paths, the installed communication modules, cable routing, and system redundancy settings. A single working path does not necessarily indicate that the complete redundant configuration is healthy.

Q4: Can AVR10D-Q22021 replace AVR10D-Q22020?

Do not assume direct interchangeability. Compare the suffix codes, power supply arrangement, network type, and installed hardware. The Q22021 configuration is specifically associated with dual-redundant V net and dual 220–240 V AC power supplies.

Q5: Is the AVR10D a standard PLC CPU?

No. Its primary function is as a Duplexed V net Router for Yokogawa CENTUM communication networks. It should not be selected as a substitute for a PLC processor or general-purpose controller.

Q6: Can it connect directly to a modern Ethernet network?

The AVR10D-Q22021 is associated with the legacy V net coaxial network configuration. Ethernet or Vnet/IP integration requires the appropriate Yokogawa network architecture and compatible interface equipment.

 

Safety Precautions

  • Disconnect and isolate both power supply inputs before removing the unit.
  • Verify the absence of hazardous voltage before handling power terminals.
  • Do not disconnect or reconnect network cables while following an unapproved maintenance procedure.
  • Protect communication modules from electrostatic discharge.
  • Maintain correct coaxial cable termination and grounding practices.
  • Use a keyed metallic cabinet to meet the specified EMC installation requirements.
  • Confirm network redundancy and communication health before restoring the process system to normal operation.
  • Installation and commissioning should be performed by personnel familiar with Yokogawa CENTUM systems.

 

Recommended Related Yokogawa Models

The following products belong to related Yokogawa communication and CENTUM system families. They are not all direct replacements for AVR10D-Q22021.

  1. Yokogawa AVR10D – Duplexed V Net Router
  2. Yokogawa AW810D – Wide Area Communication Router
  3. Yokogawa VC401 – V Net Coupler Module
  4. Yokogawa VI451 – Communication Module
  5. Yokogawa VF702 – V Net Control Bus Interface Card
  6. Yokogawa VI702 – Vnet/IP Interface Card
  7. Yokogawa PW442 – Power Supply Module
  8. Yokogawa PW482 – Power Supply Module
  9. Yokogawa AIP601 – Processor Module
  10. Yokogawa AIP602 – Processor Module
  11. Yokogawa CP451 – Processor Module
  12. Yokogawa CP461 – Processor Module
  13. Yokogawa AAI141 – Analog Input Module
  14. Yokogawa AAI543 – Analog Output Module
  15. Yokogawa ADV551 – Digital Output Module

 

Inspection and Testing Recommendations

Before dispatch, verify the model and suffix code, assembly number C2GC17255C, module labels, power supply ratings, and physical condition. Inspect the BNC connectors, rack mounting points, and internal module seating.

Where a compatible test environment is available, check power-up operation, redundant power status, communication module diagnostics, and network connectivity. Test the primary and secondary communication paths independently using an approved CENTUM maintenance procedure.

Ordering Note: AVR10D-Q22021 is a specific dual-redundant V net router configuration with dual 220–240 V AC power supplies. Confirm the suffix code, assembly number, installed modules, and network type against the existing equipment before ordering.

about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.