The GE Multilin 745 (745-W2-P5-G5-LO-A-R-E-H) is a premier transformer management relay designed to provide comprehensive protection, monitoring, and diagnostics for small, medium, and large power transformers. It is a critical component in substation automation, offering advanced features like differential protection, thermal modeling, and fault recording to ensure the longevity and reliability of power transformers. The “SR745-CASE” designates the draw-out unit enclosure, which facilitates easy testing and maintenance.
Technical Specifications
| Parameter | Detail |
| Product Model | 745-W2-P5-G5-LO-A-R-E-H |
| Series | Multilin 745 Transformer Management Relay |
| Manufacturer | GE / General Electric |
| Enclosure | SR745-CASE (Draw-out) |
| Input CTs | 5A Phase / 5A Ground |
| Control Voltage | 125/250V DC or 120/240V AC (LO – Low range option) |
| Protection Functions | Percent Differential (87), Thermal (49), Overcurrent (50/51) |
| Communication | RS232/RS485, Modbus protocol |
| Dimensions (Approx.) | 225mm x 205mm x 325mm |
| Weight | 6.5 kg |
| Country of Origin | Canada / USA |
Application Fields
- Power Substations: Primary protection for distribution and transmission transformers.
- Industrial Facilities: Monitoring large step-down transformers for factory power distribution.
- Renewable Energy: Protection of collector transformers in wind and solar farm substations.
- Data Centers: Ensuring reliable power delivery by monitoring critical transformer health.
Usage Instructions
- Installation: Slide the SR745-CASE into the panel cutout and secure it using the mounting hardware. Ensure the draw-out mechanism is fully locked to engage all rear terminal connections.
- Wiring: Connect current transformer (CT) secondary inputs, voltage inputs, and control power according to the specific wiring diagram provided in the user manual. Warning: Always short-circuit CT inputs before disconnecting the relay to prevent high-voltage build-up.
- Configuration: Use GE EnerVista 745 Setup software to configure the transformer’s vector group, CT ratios, and protection setpoints.
- Maintenance: The draw-out design allows the relay to be pulled out for testing or replacement without disturbing permanent field wiring. Periodically download and analyze the event records to monitor transformer health.
- Testing: Perform regular secondary injection testing using a relay test set to verify protection settings and output relay operations.

Frequently Asked Questions (Q&A)
- Q: What does the “W2” suffix indicate?
- A: The W2 code refers to the specific hardware configuration regarding CT inputs and I/O options. It is essential to match this when replacing a unit to ensure it aligns with your secondary CT circuits.
- Q: Can I access data remotely?
- A: Yes, via the RS485 communication ports, the 745 can be integrated into a SCADA system or accessed locally via a PC running EnerVista software.
- Q: Is this relay compatible with older electromechanical relays?
- A: The 745 is designed to replace aging electromechanical differential relays while providing significantly higher precision and integrated monitoring capabilities.
Recommended Stock Products
- 745-W2-P5-G5-LO-A-R-E-H
- SR745-CASE (Replacement Case)
- 745-W1-P5-G5-HI-A-R-E-H
- GE Multilin 750 (Feeder Relay)
- GE Multilin 760 (Feeder Relay)
- EnerVista 745 Setup Software (Interface Cable)
- RTXP8 Test Switch
- 5A Current Test Plug
- 125V DC Power Supply Module
- Replacement Display/Keypad Assembly