The Advanced Sterilization Products (ASP) 04-52006-3-001 NX System Interface Board is an essential internal electronic component designed specifically for the STERRAD NX Low-Temperature Hydrogen Peroxide Sterilization System. This specialized printed circuit board acts as a central communication and signal-routing hub, managing data exchange between the sterilizer’s core processing modules, sensors, and external system interfaces to ensure safe and repeatable medical device sterilization.

Technical Parameters & Datasheet Overview
- Part Number: 04-52006-3-001
- Product Range: ASP STERRAD NX Sterilization System Internal Spare Parts
- Compatibility: STERRAD NX / NX System Top Module & Chassis Architecture
- Board Type: Digital/Analog System Interface & Input/Output (I/O) Routing Board
- Operating Voltage: Standard low-voltage internal DC logic rails supplied by system power units
- Approximate Dimensions: Custom modular form factor tailored to fit the STERRAD NX chassis frame (approx. 250 mm x 180 mm)
- Approximate Weight: Approx. 0.4 kg (0.9 lbs)
- Country of Origin: United States / Global medical device manufacturing standards
- Condition Options: Factory Original New, Open Box Surplus, or Certified Refurbished
Applications
- STERRAD NX Sterilizer Maintenance: Utilized by biomedical engineering teams and certified technicians as a direct replacement component to repair internal communication or signal routing faults in STERRAD NX sterilizers.
- Medical Equipment Upkeep: Restores full input/output functionality between the control software, vacuum sensors, and power distribution modules.
Usage Precautions
- Electrostatic Discharge (ESD) Protection: Always handle this sensitive circuit board on an anti-static mat while wearing a grounded ESD wrist strap to prevent damaging microprocessors and logic traces.
- Power Isolation & LOTO: Completely disconnect the sterilizer from its main AC power source and allow adequate discharge time before opening service panels or disconnecting internal wiring harnesses.
- Exact Part Matching: Verify that the revision code and part number on your existing board match the 04-52006-3-001 specification precisely to guarantee software and hardware compatibility.
Parameter Settings & Configuration Methods
- Firmware Handshaking: The interface board relies on the main STERRAD NX system controller firmware; communication pathways are established automatically upon successful connection of all internal ribbon cables and plug connectors.
- Diagnostic Verification: Post-installation testing and system diagnostics must be performed via the sterilizer’s service software or built-in diagnostic menus to verify proper sensor response and signal relay.
Manual / Automatic Mode Switching
- System-Managed Operations: The interface board does not feature manual switches; all operational mode changes (such as transitioning between diagnostic, vacuum, and injection phases) are fully automated and managed by the STERRAD NX main software program.
Emergency Trip Operations
- Safety Interlock Integration: The board routes critical safety loop signals, including chamber door closures and emergency abort triggers, instantly cutting power to valves and RF generators if a fault is detected.
- Software Abort Execution: Operators can cancel active sterilization cycles directly from the HMI touchscreen, prompting the interface board to execute safe exhaust and ventilation sequences.
Frequently Asked Questions (Q&A)
Q: What is the primary function of the 04-52006-3-001 board in a STERRAD NX sterilizer?
A: It acts as an intermediate routing and interface platform that connects various internal sensors, input signals, and output actuators to the main control system.
Q: Does this board require programming or configuration prior to installation?
A: Typically, it operates as a hardware interface layer governed by the main system controller, though system calibration or service-level checks may be required by certified technicians after replacement.
Q: Are surplus or open-box replacement electronic boards tested?
A: Reputable industrial medical surplus suppliers inspect and verify physical packaging and pin integrity, but buyers should always confirm warranty terms prior to critical healthcare installations.
Industry News & Updates
Medical device reprocessing centers continue to prioritize strict compliance, traceability, and rapid maintenance turnaround for low-temperature hydrogen peroxide sterilizers. Utilizing OEM-genuine replacement electronic modules ensures that critical sterilizers like the STERRAD NX maintain strict validation standards, minimizing downtime and supporting continuous surgical instrument availability in hospital environments.
For reliable automation parts, spare components, and specialized industrial hardware, visit New PLC DCS to explore extensive inventory options.
Related Series & Alternative Models
- ASP STERRAD NX Universal Control Boards
- ASP STERRAD 100NX System Interface Modules
- ASP STERRAD 200/100S Power Supply & Control Units
- ASP STERRAD Velocity Biological Reader Modules
- ASP STERRAD Cassette Mechanism Assemblies
- STERRAD NX Touchscreen HMI Display Panels
- STERRAD NX Vacuum Pump Controller Modules
- STERRAD RF Generator Power Boards
- STERRAD Hydrogen Peroxide Monitor Sensors
- ASP Access Technology Network Interface Cards