The WEIDMULLER WAS5 PRO RTD 8560700000 is a configurable RTD isolating transformer and temperature signal converter designed for industrial measurement and control applications. It accepts PT100 and Ni100 resistance temperature signals using 2-, 3-, or 4-wire connections and converts the measured signal into standard analog process outputs such as 0–20 mA, 4–20 mA, or 0–10 V. The module provides galvanic three-way isolation between the input, output, and auxiliary power circuits, making it suitable for signal conditioning and electrical isolation between field sensors and control-system analog inputs.
The WAS5 PRO RTD uses DIP-switch configuration and potentiometers for adjustment and is designed for TS35 rail mounting. It supports a configurable PT100 temperature range of -200°C to +850°C and Ni100 from -60°C to +250°C. The compact 17.5 mm-wide housing makes it suitable for control cabinets where space is limited. Weidmüller currently identifies order number 8560700000 as discontinued and lists 1176030000 as the alternative product.

8560700000
🔧 Key Features
- Weidmüller WAS5 PRO RTD temperature transducer
- Order number 8560700000
- Configurable RTD measurement isolating transformer
- PT100 2-, 3-, or 4-wire input
- Ni100 2-, 3-, or 4-wire input
- PT100 range: -200°C to +850°C
- Ni100 range: -60°C to +250°C
- 0–20 mA and 4–20 mA current outputs
- 0–10 V voltage output
- Three-way galvanic isolation
- DIP-switch and potentiometer configuration
- TS35 DIN-rail mounting
- 24 VDC auxiliary supply
- IP20 protection
- Screw terminal connection
- Compact 17.5 mm housing width
- Official status: Discontinued
📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | WEIDMULLER |
| Model | WAS5 PRO RTD |
| Part Number | 8560700000 |
| Series | WAS5 PRO |
| Product Name | RTD Temperature Signal Converter / Isolating Transformer |
| Input | PT100 / Ni100, 2-/3-/4-wire |
| Output | 0–20 mA / 4–20 mA / 0–10 V |
| Auxiliary Power | 24 VDC ±25% |
| Isolation | 3-way galvanic isolation |
| Dimensions | 92.4 × 17.5 × 112.4 mm |
| Net Weight | 138 g |
| Mounting | TS35 DIN Rail |
| Protection Rating | IP20 |
| Operating Temperature | 0°C to +55°C |
| Condition / Status | Discontinued / Legacy Stock |
❓ Common Questions & Answers
Q: What is the WEIDMULLER WAS5 PRO RTD used for?
A: It is used to measure RTD temperature signals and convert them into standard analog signals for PLC, DCS, and industrial control systems.
Q: Which RTD sensors are supported?
A: The module supports PT100 and Ni100 sensors with 2-, 3-, or 4-wire connections.
Q: What outputs are available?
A: The module provides configurable 0–20 mA, 4–20 mA, and 0–10 V outputs.
Q: Does the module provide electrical isolation?
A: Yes. The WAS5 PRO RTD provides three-way galvanic isolation between the relevant circuits, with an impulse withstand voltage specified at 4 kV.
Q: What is the power supply?
A: The specified auxiliary supply is 24 VDC ±25%.
Q: What are the dimensions and weight?
A: The specified dimensions are 92.4 × 17.5 × 112.4 mm, with a net weight of approximately 138 g.
Q: Is 8560700000 still manufactured?
A: No. Weidmüller currently lists 8560700000 WAS5 PRO RTD as discontinued and identifies 1176030000 as an alternative product.
Q: Can it be used for a new control-system installation?
A: Weidmüller states that this product should not be used for new systems and recommends contacting technical support regarding the replacement product.
🔄 Recommended WEIDMULLER Models
- WEIDMULLER 1176030000 RTD Isolating Transformer
- WEIDMULLER 8432220000 WTZ4 PT100/2 C 0/4-20MA
- WEIDMULLER 8432190000 WTZ4 PT100/2 V 0-10V
- WEIDMULLER WAS5 PRO RTD 8560700000
- WEIDMULLER ACT20P-RTI-AO-S
- WEIDMULLER ACT20P-RTI-CO
- WEIDMULLER ACT20P-RTI-4-20
- WEIDMULLER ACT20P-2CI-2CO
- WEIDMULLER ACT20P-2CI-2CO-ILP
- WEIDMULLER ACT20M-RTI-4-20