HIMA | F3 AIO 8/4 01 | HIMatrix Safety Analog I/O Module

Original price was: $10,000.00.Current price is: $999.00.

Product NO:F3 AIO 8/4 01

Brand:HIMA

Delivery time:  In stock

Product status:   Brandnew

Product situation: one year warranty, Origin of Manufacture

There are still many products that have not been released yet. If you have any products that you cannot find, you can ask me for a quote! Reminder: The product images published on this website are not actual real products and are for reference only!

Description

Product Description

The HIMA HIMatrix F3 AIO 8/4 01 is a safety-related remote analog I/O module designed for industrial safety and process automation systems. It provides 8 safety-related analog input channels and 4 analog output channels in a compact metal housing. The analog inputs support 0–10 V DC and 0/4–20 mA signals, while the current outputs provide 4–20 mA control signals. Communication with compatible HIMA HIMatrix and HIMax controllers is handled through SafeEthernet over dual RJ45 Ethernet ports with an integrated switch. The module is certified for safety-related applications up to SIL 3 and is suitable for process monitoring, emergency shutdown systems, and industrial instrumentation. Please note that the four analog outputs are not inherently safety-related; additional feedback and application logic are required when using them in safety-related functions.

F3 AIO 8/4 01

F3 AIO 8/4 01

Key Product Parameters

  • Brand: HIMA
  • Model: F3 AIO 8/4 01
  • Product Family: HIMatrix
  • Product Name: Safety Analog Input/Output Remote I/O Module
  • Module Type: Remote Analog I/O
  • Analog Inputs: 8 channels, safety-related
  • Analog Input Signals: 0–10 V DC, 0/4–20 mA
  • Analog Input Resolution: 12-bit
  • Analog Input Accuracy: ±0.1% of full scale at 25°C
  • Safety-Related Input Accuracy: ±2% of full scale
  • Analog Outputs: 4 channels, non-safety-related
  • Analog Output Signal: 4–20 mA
  • Analog Output Resolution: 12-bit
  • Maximum Output Load: 600 Ω
  • Analog Output Accuracy: ±0.1% of full scale at 25°C
  • Communication Protocol: SafeEthernet
  • Ethernet Interfaces: 2 × RJ45, 10BASE-T/100BASE-TX
  • Network Feature: Integrated Ethernet switch
  • Operating Voltage: 24 V DC (-15% to +20%)
  • Current Consumption: Approximately 0.4 A idle; maximum 0.8 A
  • External Fuse: 10 A time-lag
  • Operating Temperature: 0 to +60°C
  • Storage Temperature: -40 to +85°C
  • Protection Rating: IP20
  • Dimensions: 207 × 114 × 97 mm (without connectors)
  • Weight: Approximately 1 kg
  • Mounting: 35 mm DIN rail
  • Safety Certification: Up to SIL 3, Category 4, PL e
  • Product Status: New; verify actual packaging and condition
  • Country of Origin: Germany
  • Discontinued Status: Confirm with HIMA

 

Installation and Operating Procedures

  1. Preparation
    • Verify the exact F3 AIO 8/4 01 model and hardware revision.
    • Confirm compatibility with the existing HIMA HIMatrix or HIMax controller.
    • Check the controller operating system and programming environment.
    • Prepare the application configuration, network parameters, and I/O channel assignments.
    • Inspect the module housing, terminal connectors, Ethernet ports, and labels.
  2. Installation
    • Disconnect the 24 V DC supply before installation.
    • Mount the module on a 35 mm DIN rail.
    • Ensure sufficient ventilation and cabinet clearance.
    • Connect the 24 V DC supply using a suitably isolated PELV or SELV power source.
    • Connect analog input and output wiring according to the HIMA terminal assignment.
    • Use shielded twisted-pair cables for analog inputs and follow the specified grounding arrangement.
    • Connect the Ethernet ports to the configured SafeEthernet network.
  3. Power-On Checks
    • Verify supply voltage and polarity.
    • Check the operating voltage LED.
    • Inspect RUN, ERROR, PROG, and communication indicators.
    • Confirm that the module establishes communication with the assigned controller.
    • Check for configuration, channel, and communication faults before enabling the application.
  4. Configuration
    • Use SILworX for compatible CPU operating system version 7 and later.
    • Use ELOP II Factory for compatible operating system versions up to V6.x.
    • Configure the module IP address and system rack slot identification.
    • Assign the eight analog input channels and four analog output channels.
    • Select the appropriate input signal range and shunt adapter for current measurement.
    • Configure output scaling and the application response to communication or channel faults.
    • Verify the safety-related input logic and output feedback arrangements.
  5. Normal Operation
    • Monitor SafeEthernet communication and module status.
    • Verify analog input values against field instrument readings.
    • Check the 4–20 mA output signals using suitable measuring equipment.
    • Confirm that configured fault reactions operate correctly.
    • Record the final I/O configuration and commissioning results.
  6. Shutdown
    • Place the controlled process in its defined safe state.
    • Stop the system using the approved HIMA shutdown procedure.
    • Isolate the 24 V DC supply before disconnecting wiring.
    • Verify that the module is de-energized before removal or maintenance.

 

Daily Maintenance

  • Check RUN, ERROR, and communication indicators.
  • Monitor SafeEthernet communication status.
  • Inspect Ethernet connectors and field wiring.
  • Check the 24 V DC supply and cabinet ventilation.
  • Verify analog input readings against field instrument values.
  • Inspect analog output circuits for abnormal loading.
  • Check grounding and cable shielding.
  • Review module diagnostic messages and channel fault codes.
  • Maintain backups of the HIMA safety application and configuration.
  • Perform proof testing according to the approved safety maintenance schedule.

 

Troubleshooting

  • Module does not power up: Check the 24 V DC supply, polarity, external fuse, and terminal connections.
  • SafeEthernet communication failure: Check Ethernet cables, IP configuration, system rack slot identification, and network settings.
  • RUN LED does not remain active: Review the operating system, application configuration, and diagnostic messages.
  • Analog input reading is incorrect: Verify signal range, field wiring, grounding, and current shunt adapter.
  • Analog input fault: Check sensor wiring, channel configuration, and AI diagnostic codes.
  • Analog output is incorrect: Verify output scaling, channel configuration, load impedance, and field wiring.
  • ERROR LED is active: Check internal diagnostics, configuration validity, and controller communication.
  • Intermittent operation: Inspect power stability, Ethernet connections, electrical interference, and grounding.

 

Safety Precautions

  • Installation and commissioning must be performed by qualified functional-safety personnel.
  • Disconnect power before installing or removing the module.
  • Use an isolated 24 V DC PELV or SELV power supply.
  • Follow HIMA’s specified terminal assignments and cable-shielding requirements.
  • Do not exceed the specified analog input ranges or output load impedance.
  • Do not assume the four analog outputs are safety-rated.
  • If analog outputs are used in a safety-related application, implement the required readback and evaluation through safety-related analog inputs.
  • Validate the complete safety application after hardware replacement or configuration changes.
  • Follow the official HIMA HIMatrix F3 AIO 8/4 01 manual and site safety procedures.

 

Product Keywords

HIMA F3 AIO 8/4 01, HIMatrix F3 AIO, HIMA analog I/O module, 8 analog input module, 4 analog output module, safety analog remote I/O, SafeEthernet module, SIL 3 safety controller, 4–20 mA analog module, 0–10 V input module, HIMA HIMax, industrial safety automation, process control spare parts.

For more industrial automation products and replacement components, visit www.newplcdcs.com.

 

15 Related / Recommended Models

The following HIMA HIMatrix and HIMax products are related safety automation components for system expansion and maintenance research. They have different I/O functions and are not direct replacements for F3 AIO 8/4 01.

  1. HIMA F3 AIO 8/4 011 – Extended-temperature analog remote I/O
  2. HIMA F3 AIO 8/4 012 – Subsea analog remote I/O
  3. HIMA F3 AIO 8/4 014 – Railway application analog remote I/O
  4. HIMA F3 DIO 8/8 01 – Digital input/output remote I/O
  5. HIMA F3 DIO 16/8 01 – Digital I/O remote I/O
  6. HIMA F1 DI 16 01 – Digital input remote I/O
  7. HIMA F2 DO 4 01 – Digital output module
  8. HIMA F2 DO 8 01 – Digital output module
  9. HIMA F2 DO 16 01 – Digital output module
  10. HIMA F2 DO 16 02 – Relay output module
  11. HIMA F35 – HIMatrix safety controller
  12. HIMA F60 – HIMatrix modular safety system
  13. HIMA F20 – HIMatrix compact safety controller
  14. HIMA F30 – HIMatrix remote I/O and controller family
  15. HIMA HIMax – Modular safety control system
about us

At Newplcdcs, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.

Contact Information

Frequently Asked Questions
Is our price competitive?
Newsplcdcs collaborates with over 50 countries worldwide. as a leading supplier in china, we can provide significant discounts to customers based on market demand.
What is the warranty period?
We offer a standard one-year warranty for all new and original items.
What payment methods do we accept?
We accept 100% t/t (telegraphic transfer) before shipping. for items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. if you have an agent in china, please contact us for rmb transfer.
What shipping methods do we use?
We primarily utilize carriers such as fedex, dhl, ups, bre, etc. if you have an account with any of these carriers, you can arrange the shipping yourself. additionally, we offer free shipping to china freight forwarders.
What is our delivery time?
Typically, delivery takes around 1-3 days after receiving the advance payment. for items with a quoted lead time, delivery will occur as per the specified lead time.
How do we package the goods?
Our packaging process involves multiple layers of protection. initially, the product is placed in its original box, sealed with a label. then, we add a layer of bubble wrap to safeguard against collisions during transportation. finally, all products are securely packed in sturdy boxes for further protection.
How can customers contact us and request a quote?
Customers can inquire via email, whatsapp, wechat, skype, or any preferred communication platform. simply reach out to us, and we’ll promptly provide a quote tailored to your needs.