Description
Product Description
The HIMA HIMatrix F35 01 is a compact programmable safety controller designed for safety-related automation, machine protection, and process control applications. It integrates 24 digital inputs, 8 digital outputs, 8 analog inputs, and 2 counter channels in a single controller. Certified for safety applications up to SIL 3, the F35 supports safety functions such as emergency shutdown, equipment interlocking, process monitoring, and protective logic execution. This listing also includes four HIMA Z7306 shunt adapters for interfacing compatible 4–20 mA current signals with the controller’s analog inputs. Each Z7306 adapter provides a 250 Ω shunt, overvoltage protection, and a HART series resistor. The combination is suitable for installations requiring analog process measurement within a HIMatrix safety-control architecture. Verify the controller’s programming platform, firmware, terminal connections, and safety application requirements before commissioning.

HIMatrix F35 01
Key Technical Specifications
- Brand: HIMA
- Controller Model: HIMatrix F35 01
- Accessory Model: Z7306
- Accessory Quantity: 4 × Z7306 Shunt Adapters
- Controller Type: Compact Safety PLC
- Product Series: HIMatrix
- Digital Inputs: 24
- Digital Outputs: 8
- Analog Inputs: 8
- Counter Channels: 2
- Counter Resolution: 24-bit
- Maximum Counter Frequency: Up to 100 kHz, depending on configuration
- Analog Input Measurement Range: 0–10 V DC
- Current Measurement: 0–20 mA using an appropriate shunt adapter
- Analog Input Resolution: 12-bit
- Z7306 Shunt Resistance: 250 Ω
- Z7306 Functions: Current-to-voltage conversion, overvoltage protection, and HART series resistance
- Z7306 Compatibility: HIMatrix F35 analog inputs and compatible HIMA F3 AIO 8/4 01 modules
- Safety Certification: Up to SIL 3, subject to the approved system configuration and application requirements
- Additional Safety Standards: Category 4 and PL e, according to applicable certification
- Programming Platforms: SILworX or ELOP II Factory, depending on controller variant
- Nominal Supply Voltage: 24 V DC
- F35 01 Operating Temperature: 0 to +60°C
- F35 01 Protection Rating: IP20
- Installation: DIN rail mounting
- Z7306 HIMA Part Number: 98 2220115
- Controller Country of Origin: Verify on the individual nameplate
- Product Condition: Not specified; confirm with the seller
Installation and Operating Instructions
- Verify the controller label and confirm that the unit is the F35 01 variant.
- Confirm whether the installed controller is configured for SILworX or ELOP II Factory.
- Inspect the controller, terminal connectors, and four Z7306 adapters for physical damage.
- Install the F35 controller on the approved DIN rail or mounting arrangement.
- Isolate the 24 V DC supply before wiring or installing the shunt adapters.
- Install each Z7306 adapter at the appropriate analog input connection according to the HIMA wiring diagram.
- Connect compatible 4–20 mA transmitters using the specified analog input terminals and correct polarity.
- Verify the analog input channel assignment and signal scaling in the safety application.
- Configure transmitter diagnostics, signal limits, and fault reactions according to the approved safety requirements.
- Check digital input and output wiring, counter connections, and fieldbus interfaces.
- Load the validated application using the correct HIMA engineering software and compatible hardware configuration.
- Perform a documented functional test of all safety inputs, outputs, analog channels, and connected actuators before commissioning.
Daily Maintenance
- Check controller status indicators and diagnostic messages.
- Inspect terminal connections for looseness, corrosion, or overheating.
- Verify the 24 V DC power supply and grounding.
- Check analog transmitter readings for abnormal fluctuations.
- Inspect the four Z7306 adapters for secure installation.
- Monitor fieldbus and communication diagnostics.
- Review safety-controller fault logs and system event records.
- Check cabinet temperature and environmental conditions.
- Verify that safety application backups and configuration records are current.
- Perform periodic proof testing according to the plant’s safety lifecycle and maintenance schedule.
Troubleshooting and FAQ
Q1: What is the function of the HIMA F35 01?
It is a compact safety controller used to execute safety-related logic, process field signals, and control safety-related outputs in industrial automation systems.
Q2: What does the Z7306 shunt adapter do?
The Z7306 converts a compatible current signal into a voltage signal suitable for an F35 analog input. It incorporates a 250 Ω shunt, overvoltage protection, and a HART series resistor.
Q3: Why are four Z7306 adapters included?
The four adapters provide additional current-input interfacing for selected analog channels. The actual number of channels used depends on the transmitter wiring and application design.
Q4: Can the F35 01 accept 4–20 mA signals directly?
The F35 analog inputs are voltage-measuring inputs. An appropriate external shunt adapter, such as the Z7306, is required for the specified current-measurement arrangement.
Q5: Is the F35 01 suitable for SIL 3 applications?
The F35 is certified for safety-related applications up to SIL 3. The complete safety function must still meet the required architecture, hardware, software, diagnostic, proof-test, and application constraints.
Q6: Which programming software is required?
The required engineering environment depends on the controller’s hardware and firmware variant. F35 configurations are associated with SILworX and ELOP II Factory. Confirm the installed variant before programming or replacing the unit.
Q7: Can the F35 01 replace another HIMatrix controller?
Not automatically. Check the I/O configuration, communication interfaces, firmware, programming environment, application compatibility, and safety certification before substitution.
Safety Precautions
- Only qualified functional-safety and instrumentation personnel should install or commission this equipment.
- Isolate the 24 V DC supply before wiring or removing modules.
- Use electrostatic discharge protection when handling controller electronics.
- Follow the approved HIMA safety manual and terminal assignment diagrams.
- Do not exceed analog input voltage or current limits.
- Verify the Z7306 shunt resistance and wiring before connecting transmitters.
- Use suitable shielded cables and grounding practices for analog signals.
- Do not modify validated safety logic without formal change management and revalidation.
- Never bypass safety interlocks or protective functions during normal operation.
- Confirm the complete safety function through documented validation and proof testing before returning the plant to service.
Related HIMA Models and Components
The following are related HIMA HIMatrix controllers, remote I/O products, and signal-conditioning accessories. They are not guaranteed direct replacements:
- HIMatrix F35 011 – Extended-Temperature Safety Controller
- HIMatrix F35 012 – Subsea / Extended-Environment Safety Controller
- HIMatrix F35 03 – Enhanced HIMatrix Safety Controller
- HIMatrix F60 – Modular Safety Controller
- HIMatrix F30 – Compact Safety Controller
- HIMatrix F31 – Compact Safety Controller
- HIMatrix F20 – Compact Safety Controller
- HIMatrix F3 AIO 8/4 01 – Analog Input/Output Remote I/O Module
- HIMatrix F3 DIO 20/8 01 – Digital Input/Output Remote I/O Module
- HIMatrix F3 DIO 16/8 01 – Digital Input/Output Remote I/O Module
- Z7301 – 250 Ω Shunt Adapter
- Z7302 – 500 Ω Shunt Adapter
- Z7306 – 250 Ω Shunt Adapter with Overvoltage Protection and HART Resistor
- Z7308 – Voltage Divider Adapter with Overvoltage Protection
- HIMatrix F3 series – Distributed Safety I/O Modules
Always verify the exact hardware variant, I/O arrangement, communication interfaces, firmware, engineering software, and safety certification before selecting a related product as a replacement.
Product Keywords
HIMA HIMatrix F35 01, HIMA F35 Safety Controller, HIMA Safety PLC, SIL 3 Safety Controller, Z7306 Shunt Adapter, HIMA 98 2220115, 250 Ohm Shunt, HART Signal Interface, 4–20 mA Analog Input, Industrial Safety System, Functional Safety PLC, Process Safety Controller, Emergency Shutdown System, HIMA Automation Spare Parts.
For industrial automation and safety-system spare parts, visit https://www.newplcdcs.com.