Description
Product Description
The Honeywell 261A1812P013 Flame Sensor is an industrial flame detection component designed for use in compatible burner management and combustion control systems.
Flame sensors play an important role in combustion safety by detecting the presence of a flame and providing feedback to the associated flame safeguard controller. This feedback helps the control system monitor burner operation and initiate appropriate safety responses when flame conditions are abnormal.
The 261A1812P013 is intended for applications involving industrial burners, combustion equipment, and compatible heating systems. Proper sensor selection, installation, and calibration are essential for dependable flame monitoring.
Before installation, verify the sensor technology, operating characteristics, electrical connections, and compatibility with the specific Honeywell flame safeguard controller.

261A1812P013
Product Parameters
- Brand: Honeywell
- Model: 261A1812P013
- Part Number: 261A1812P013
- Series: Honeywell Flame Detection Components
- Product Name: Flame Sensor
- Product Type: Industrial Flame Detection Device
- Application: Burner Management and Combustion Safety
- Place of Manufacture: Honeywell manufacturing facility; exact location unverified
- Product Status: Industrial spare part; actual condition subject to inspection
- Dimensions: Not officially verified
- Weight: Not officially verified
- Country of Origin: To be confirmed from product nameplate
- Power Requirements: Dependent on sensor technology and compatible control system
- Discontinued Status: Not independently confirmed
Main Applications
🔥 Industrial Burner Monitoring
Detects flame conditions in compatible industrial combustion equipment.
🏭 Boiler Systems
Supports flame monitoring in suitable boiler burner installations.
⚙️ Combustion Control
Provides flame-status feedback to compatible burner management systems.
🛡️ Flame Safety Protection
Helps the associated controller identify flame failure and support appropriate safety shutdown functions.
Daily Maintenance and Care
- Inspect the sensor body and mounting assembly for cracks, corrosion, or physical damage.
- Keep the sensing surface and optical viewing area clean where applicable.
- Check wiring insulation, connectors, and grounding connections.
- Inspect the sensor mounting position and ensure the required flame viewing alignment.
- Monitor flame detection signals during normal burner operation.
- Check for intermittent flame signals and unexplained flame failure alarms.
- Follow the manufacturer’s inspection and replacement intervals.
- Record maintenance activities and sensor replacement dates.
- Use only approved cleaning methods to avoid damaging the sensing element.
Troubleshooting and Frequently Asked Questions
Q1: What is the Honeywell 261A1812P013 used for?
A: It is identified as a flame sensor for compatible industrial burner and combustion monitoring applications.
Q2: Why does the burner controller report flame failure?
A: Possible causes include a weak or unstable flame, incorrect sensor positioning, damaged wiring, contamination, or a defective sensing component.
Q3: Why does the sensor produce an intermittent flame signal?
A: Check the sensor mounting position, wiring connections, combustion stability, electrical interference, and sensing surface condition.
Q4: Can this sensor be used with any Honeywell burner controller?
A: No. Compatibility must be verified against the controller model, sensor technology, electrical characteristics, and manufacturer specifications.
Q5: How often should the flame sensor be inspected?
A: Inspection frequency depends on burner operating hours, environmental conditions, and the equipment manufacturer’s maintenance schedule.
Q6: Can a faulty flame sensor affect burner safety?
A: Yes. Incorrect flame detection can cause nuisance shutdowns or compromise the intended safety monitoring function. Defective sensors must be replaced with approved compatible components.
Safety Precautions
⚠️ Shut down the burner and isolate the relevant power sources before maintenance.
⚠️ Follow the approved burner shutdown and lockout/tagout procedures.
⚠️ Never bypass flame detection or flame safeguard protection circuits.
⚠️ Do not operate combustion equipment with an unreliable flame detection system.
⚠️ Verify sensor compatibility and wiring before commissioning.
⚠️ Flame detection testing must be performed by qualified combustion safety technicians.
⚠️ After replacement, perform the required flame failure and safety interlock tests according to the burner manufacturer’s procedures.
Recommended Honeywell Models
- Honeywell C7027A – Minipeeper Ultraviolet Flame Detector
- Honeywell C7035A – Ultraviolet Flame Detector
- Honeywell C7061A – Dynamic Self-Check Ultraviolet Flame Detector
- Honeywell C7012A – Ultraviolet Flame Detector
- Honeywell C7012E – Ultraviolet Flame Detector
- Honeywell C7027 – Ultraviolet Flame Detector
- Honeywell C7915 – Infrared Flame Detector
- Honeywell C7961 – Dynamic Self-Check Ultraviolet Flame Detector
- Honeywell R7861A – Dynamic Self-Check Amplifier
- Honeywell R7847A – Flame Signal Amplifier
- Honeywell R4343E – Flame Switch
- Honeywell RM7890A – Burner Control Module
- Honeywell RM7800 – Burner Control System
- Honeywell EC7895A – Burner Control Module
- Honeywell 7800 SERIES – Burner Management System
Note: The recommended models belong to Honeywell’s broader flame detection and burner management portfolio. They are not confirmed direct replacements for the 261A1812P013. Verify sensing technology, electrical specifications, and controller compatibility before ordering.