The ABB DSAI145 57120001-HA is a high-precision Resistance Temperature Detector (RTD) input module designed for the Advant Open Control System (OCS). It serves as a specialized interface for temperature measurement, converting low-level signals from RTD sensors into digital values that the S600 I/O system and Advant controllers can process.
For technical documentation or to request a formal quote, please visit our DSAI145 57120001-HA contact page.
Technical Description and Parameters
The DSAI145 is engineered to provide stable and accurate temperature readings in industrial environments. It typically supports various types of RTD sensors, such as Pt100 or Ni100, and utilizes a multi-wire connection method to compensate for lead-wire resistance.
- Module Type: Analog RTD Input Module
- Series: Advant OCS / S600 I/O
- Number of Channels: 16 Channels
- Input Types: Pt100, Ni100, Ni120, and Cu10 sensors
- Measurement Range: -200°C to +850°C (depending on sensor type)
- Resolution: 14-bit A/D conversion
- Isolation: Group-wise galvanic isolation
- Update Rate: Approx. 500 ms for all channels
Product Datasheet Specifications
- Dimensions: 273 mm x 40 mm x 190 mm
- Weight: 0.85 kg (1.87 lbs)
- Country of Origin: Sweden
- Mounting: I/O subrack for Advant OCS / S600
- Power Consumption: +5V DC, 200mA (from system bus)
Application Fields
The DSAI145 is critical in processes where temperature precision directly impacts product quality or equipment safety:
- Thermal Power Plants: Monitoring bearing temperatures in turbines and large motor windings.
- Chemical Industry: Tracking reactor temperatures and exothermic reaction zones.
- Steel and Glass Production: High-temperature furnace monitoring and cooling system oversight.
- Pharmaceuticals: Precise environmental control for fermentation and sterilization processes.

Product Instructions for Use
- Sensor Wiring: Connect RTD sensors using 3-wire or 4-wire configurations to ensure high accuracy. The module compensates for lead resistance automatically in 3-wire mode.
- Module Insertion: Ensure the subrack is powered off or follow the system’s “Live Insertion” guidelines. Align the module with the guide rails and press firmly until the connectors engage.
- Configuration: Use the Advant Station Engineering tool (e.g., AMPL or Control IT) to define the sensor type and linearization parameters for each specific channel.
- Calibration: While the module is factory-calibrated, it is recommended to perform a loop check using a temperature calibrator during commissioning to verify end-to-end signal integrity.
Q&A: Frequently Asked Questions
Q: Can I use 2-wire RTD sensors with the DSAI145? A: Yes, but it is not recommended for high-accuracy applications because the module cannot compensate for the resistance of the lead wires. If used, jumpers must be placed at the terminal block.
Q: What does the “F” LED on the front panel indicate? A: The red “F” (Fault) LED indicates a hardware failure within the module or a configuration error that prevents the module from communicating with the controller.
Q: Is the 57120001-HA version different from older DSAI145 models? A: The “HA” suffix typically refers to a specific revision or coating level (such as G3 conformal coating for harsh environments). Always ensure the revision matches your system’s hardware environment.
Related Product News
As industrial facilities move toward digitalization, ABB continues to offer lifecycle services for the Advant OCS family, which includes the DSAI145. Recent service bulletins emphasize the importance of monitoring legacy I/O modules for environmental degradation, especially in older plants. ABB has introduced modernizing gateways that allow the S600 I/O series to communicate with newer 800xA controllers, effectively extending the functional life of the DSAI145 modules while upgrading the central control intelligence. This allows operators to maintain their existing field wiring and RTD sensor investments while benefiting from modern software capabilities.