The ABB DSF615BJ1E (Part Number: 1VH991012322) is a specific configuration of the highly regarded REF615 protection relay series. As a key component of the ABB Relion® family, this feeder protection relay is designed for the protection, control, measurement, and supervision of utility and industrial power distribution systems.
Product Specifications
| Feature | Specification Details |
| Product Name | ABB REF615 Feeder Protection Relay |
| Model/Config | DSF615BJ1E |
| Part Number | 1VH991012322 |
| Manufacturer | ABB |
| Series | Relion® 615 series |
| Application | Distribution feeder protection and control |
| Communication | Supports IEC 61850, Modbus, DNP3, etc. |
Application Fields
The REF615 is widely used in power systems to ensure grid stability and asset longevity:
- Medium-Voltage Distribution: Providing comprehensive protection for overhead lines and cable feeders.
- Industrial Power Systems: Protecting critical electrical infrastructure in manufacturing plants, mines, and data centers.
- Smart Substations: Serving as an intelligent electronic device (IED) for automated grid management and reporting.
- Utility Grids: Delivering reliable fault isolation to prevent widespread outages during network disturbances.
Testing and Commissioning Guide
Testing an ABB REF615 relay requires precision and adherence to manufacturer guidelines to ensure reliability:
- Software Configuration: Use the ABB PCM600 tool to manage relay configurations. Ensure the configuration file matches the site-specific protection logic requirements.
- Functional Testing:
- Secondary Injection: Use a professional relay test set (e.g., Omicron or Doble) to inject current and voltage signals into the analog inputs to verify tripping thresholds for overcurrent, earth fault, and other protection functions.
- Logic Testing: Trigger internal binary inputs to test the automation and control logic, such as breaker control or interlocking sequences.
- Communication Testing: Verify that the relay correctly transmits data via the chosen protocol (e.g., IEC 61850) to the substation HMI or SCADA system.
- Safety Verification: Ensure all current transformer (CT) circuits are properly shorted and voltage transformer (VT) circuits are fused/isolated before performing any physical wiring checks.

Frequently Asked Questions (Q&A)
Q: Is the DSF615BJ1E compatible with modern substation automation?
A: Yes, the REF615 series is specifically designed for modern smart grids and supports a wide range of international communication protocols including native support for IEC 61850.
Q: Where can I find the specific technical manual for this part number?
A: You can find detailed documentation by entering the part number (1VH991012322) into the ABB Library portal, which provides the latest technical manuals and firmware release notes for the 615 series.
Q: What should I do if the relay displays a self-diagnostic error?
A: First, check the event log via the local HMI or PCM600 to identify the specific error code. If it indicates a hardware fault, the relay may require factory inspection or service. If it is a configuration error, check your protection settings in PCM600.
Q: Can I perform firmware updates in the field?
A: Yes, firmware updates can be performed using PCM600 and the relevant Connectivity Package. Always ensure a backup of the existing relay settings is saved before starting an update.
Recommended Similar Products
- ABB REF615 Feeder Protection Relay (Other Configurations)
- ABB REX615 Multifunction Protection Relay
- ABB REM615 Motor Protection Relay
- Siemens SIPROTEC 7SJ82 Protection Relay
- Schneider Electric Easergy P3 Feeder Relay