The BRAUN E1667.211 is a high-precision, safety-critical monitoring module designed to meet the rigorous requirements of SIL 3 (Safety Integrity Level) under IEC 61508 standards. It is primarily used for overspeed protection and rotational speed monitoring in hazardous and critical industrial applications. By providing reliable, fail-safe monitoring of speed, frequency, and rotation, it ensures the mechanical integrity of rotating machinery and prevents dangerous overspeed conditions.

Product Specifications
| Feature | Specification |
| Model | BRAUN E1667.211 |
| Safety Standard | SIL 3 / IEC 61508 |
| Function | Speed/Overspeed Monitoring |
| Output | Fail-safe Relay Outputs |
| Weight | Approx. 0.65 kg |
| Dimensions | Standard DIN-rail mount housing |
| Operating Temp | -20°C to +70°C |
| Origin | Germany |
Applications
This module is widely deployed in industries where safety is non-negotiable:
- Steam and Gas Turbine Overspeed Protection
- Turbo-Compressor Monitoring
- Centrifugal Pump Safety Systems
- Hazardous Area Machinery (Ex-rated environments)
- Critical Industrial Power Generation
Usage Instructions
- Mounting: Secure the E1667.211 onto a standard 35mm DIN rail. Ensure adequate space for ventilation to prevent thermal buildup.
- Wiring: Connect input signals from speed sensors (such as MPU or proximity switches) to the designated input terminals. Use shielded cables to prevent signal distortion.
- Configuration: Utilize the BRAUN-specific configuration interface (often via DIP switches or serial connection depending on the exact sub-revision) to set trip levels and hysteresis parameters.
- Testing: Perform a functional safety proof test periodically. Trigger a simulated speed signal higher than the setpoint to verify that the relay drops out (de-energizes) within the specified response time.
- Safety Compliance: Ensure the installation complies with the facility’s overall Safety Instrumented System (SIS) design documentation.
Frequently Asked Questions (Q&A)
Q: Does this module require an external safety PLC to function?
A: No, the E1667.211 is an independent safety device (Logic Solver). However, it is often integrated into a larger SIS architecture to trigger final elements like emergency stop valves.
Q: How often must the module be proof-tested?
A: The proof-test interval is defined by your site’s safety calculation (PFDavg). Refer to the product manual for the manufacturer-recommended interval to maintain SIL 3 certification.
Q: Can I use this for non-safety applications?
A: While it can be used for general monitoring, its primary design and cost reflect its high-reliability SIL 3 rating. It is best suited for applications where human safety or high-value asset protection is the priority.
Recommended Related Products
- BRAUN A5S Speed Sensors
- BRAUN E1667.212 Monitoring Module
- BRAUN D161 Series Speed Transmitters
- BRAUN Tachometer Indicators
- Woodward ProTech-GII Overspeed System
- Pepperl+Fuchs Safety Barriers
- ABB Safety Relay Modules
- IFM Electronic Speed Monitors
- MTL Safety Relays
- TURCK Intrinsically Safe Isolators