The Honeywell 51303940-150 (often associated with Rittal 9967295) is a high-performance fan assembly designed for critical thermal management in industrial control enclosures. This unit is specifically engineered to provide forced-air cooling for Honeywell Experion PKS and similar DCS (Distributed Control System) cabinets. By maintaining optimal operating temperatures, this fan assembly prevents component overheating, thereby extending the lifecycle of sensitive electronic modules and ensuring system reliability.
Technical Specifications
| Parameter | Detail |
| Product Model | 51303940-150 (Rev: G) |
| OEM Reference | Rittal 9967295 |
| Manufacturer | Honeywell / Rittal |
| Function | Enclosure Cooling / Forced Air Ventilation |
| Operating Voltage | 24V DC / 115V AC (Dependent on configuration) |
| Airflow Capacity | Optimized for standard DCS rack dimensions |
| Mounting | Top or Side Panel Mount |
| Dimensions (Approx.) | 300mm x 300mm x 150mm |
| Weight | 1.5 kg |
| Country of Origin | Germany / USA |
Application Fields
- DCS Enclosures: Cooling for Honeywell Experion PKS server and controller cabinets.
- Server Racks: Thermal management for high-density networking and computing hardware.
- Factory Automation: Preventing heat buildup in power supply and PLC housings.
- Data Centers: Ensuring airflow consistency in mission-critical hardware environments.
Usage Instructions
- Installation: Ensure the power supply is disconnected before installation. Mount the fan unit securely using the provided hardware, ensuring the airflow direction arrow on the fan housing matches the required exhaust path of the cabinet.
- Connectivity: Connect the power leads to the designated 24V DC or AC terminal blocks as specified by your cabinet’s electrical schematic.
- Sealing: Use the included gaskets to ensure an airtight seal between the fan assembly and the enclosure wall, preventing dust ingress and maintaining pressure.
- Maintenance: Periodically inspect the fan blades for dust and debris buildup. Clean with compressed air or a soft brush to maintain peak CFM (cubic feet per minute) performance.
- Monitoring: If the cabinet is equipped with a fan-fail alarm relay, wire the monitoring terminals to your DCS input module to receive alerts if the fan speed drops below the threshold.

Frequently Asked Questions (Q&A)
- Q: Is the 51303940-150 Rev:G compatible with older revision cabinets?
- A: Yes, this model is designed to be backwards compatible with most standard Honeywell enclosure footprints that utilize the Rittal 9967295-style mounting interface.
- Q: Why is “Revision G” important?
- A: The revision letter indicates manufacturing updates, which may include improvements in bearing durability, noise reduction, or updated electrical protection circuitry.
- Q: How do I know if the fan has failed?
- A: Aside from the audible change in noise, if your system has an integrated monitoring cable, an alarm will trigger in your HMI/DCS diagnostics. Otherwise, perform manual checks during routine cabinet inspections.
Recommended Stock Products
- 51303940-150 (Fan Assembly)
- 51304337-150 (Filter Kit)
- 51303940-100 (Legacy Revision Fan)
- 51195045-100 (Power Supply Module)
- 51403487-100 (Control Module)
- 51192868-100 (I/O Module)
- 51304362-150 (Cabinet Fan Tray)
- 51304453-100 (Thermal Sensor)
- 51304671-175 (Air Intake Louver)
- 51303940-200 (High-Capacity Replacement Fan)