The General Electric GN240M3XXSFXXXX is an advanced 4000A electronic trip unit belonging to the EntelliGuard L/SL product family. Designed for high-capacity power circuit breakers, this microprocessor-based protective relay provides precise current sensing, customizable protection curves, and reliable fault isolation for critical industrial power distribution systems and heavy commercial switchgear.
Technical Parameters & Datasheet Overview
- Product Model / Catalog Number: GN240M3XXSFXXXX
- Product Series: GE EntelliGuard L/SL Trip Unit Family
- Maximum Current Rating: 4000 Amperes (4000A frame configuration)
- Sensing Technology: True-RMS microprocessor-based current sensing for high measurement accuracy
GE Industrial Solutions
- Protection Types: Long-time (L), Short-time, and Selective/Instantaneous (SL) protection profiles
- Display & Programming: Integrated LCD screen with user-friendly keypad navigation for setting adjustments
GE Industrial Solutions
- Approximate Dimensions: Standard modular form factor designed for seamless integration into GE EntelliGuard circuit breaker front fascias (approx. 220 mm x 140 mm x 90 mm)
- Approximate Weight: Approx. 2.0 kg (4.4 lbs)
- Country of Origin: United States / Global manufacturing standards
- Operating Temperature Range: −20∘C to +70∘C industrial environment standard

Applications
- Heavy Industrial Switchgear: Deployed as the core intelligence and overcurrent protection relay inside main incoming and feeder air circuit breakers.
- Commercial Power Distribution: Protects high-capacity electrical distribution systems in large commercial complexes, data centers, and institutional facilities.
- Generator & Transformer Protection: Integrates into main distribution circuits requiring precise selectivity and coordination to prevent nuisance tripping.
Usage Precautions
- Electrostatic Discharge (ESD): Always utilize a grounded wrist strap and proper ESD mitigation procedures when handling or programming the trip unit module.
- Control Power Verification: Ensure auxiliary control power requirements are met where applicable before attempting software configuration or diagnostic testing.
- Rating Plug Compatibility: Verify that the installed rating plug precisely matches the sensor rating of the specific breaker frame before placing the system back into service.
Parameter Settings & Configuration Methods
- Keypad Navigation: Access protection thresholds, time delays, and pickup settings directly using the integrated front-panel pushbuttons and LCD menu.
- Software Configuration: Parameters can also be reviewed or modified using dedicated GE service tools and testing kits connected via the front diagnostic port.
- Non-Volatile Memory: Configured trip curves and settings are saved securely in onboard memory, protecting configuration integrity during power interruptions.
Manual / Automatic Mode Switching
- Autonomous Protection: Once programmed, the trip unit operates completely autonomously, continuously monitoring line currents in real-time.
- Test and Simulation Modes: Technicians can execute local display checks, battery backups, and secondary-injection testing via the service interface without disrupting primary live circuits.
Emergency Trip Operations
- Direct Breaker Tripping: Upon detecting a sustained overload, short circuit, or user-configured fault threshold crossing, the unit instantly sends an electrical trip signal to the breaker shunt trip mechanism.
- Manual Force Trip: Authorized operators can initiate a direct trip command via system interface menus or designated test routines when performing safety verifications.
Frequently Asked Questions (Q&A)
Q: What does the “L/SL” designation signify on this EntelliGuard unit? A: It indicates that the unit is equipped with Long-time (L) protection alongside Short-time and Selective/Instantaneous (SL) protection options for precise coordination.
Q: Can this trip unit be retrofitted into older GE circuit breakers? A: EntelliGuard units are specifically engineered for the EntelliGuard line of power circuit breakers; check frame compatibility and technical bulletins before attempting swaps.
Q: Does the unit require an external power supply to view settings? A: A handheld test kit or auxiliary 24V DC power source can be plugged into the front port to illuminate the display and review settings when the main breaker is de-energized.
Industry News & Updates
Modern low-voltage power distribution systems increasingly rely on intelligent trip units with advanced metering, event logging, and digital communication capabilities. Upgrading or maintaining breaker protection with genuine microprocessor-based units like the GE EntelliGuard series allows facilities management teams to enhance arc-flash safety, optimize selective coordination, and minimize unplanned electrical downtime.
For reliable automation parts, spare components, and specialized industrial hardware, visit New PLC DCS to explore extensive inventory options.
Related Series & Alternative Models
- GE EntelliGuard G Power Circuit Breakers
Kempston Controls
- GE EntelliGuard TU Trip Unit Spare Series
ABB
- GE Spectra RMS Microprocessor Trip Units
- GE Power Break II Circuit Breakers
- ABB EntelliGuard L/M/H Trip Units
- GE WavePro Trip Units
- GE Epic Microprocessor-Based Relays
- GE MicroVersaTrip Series
- GE Zenith Transfer Switch Controllers
- GE EntelliGuard Rating Plug Accessories