1. Product Description
The Bosch Rexroth IndraDrive CDB01.1C-PB-ENS-ENS-NNN-NNN-S1-S-NN-FW is a BASIC UNIVERSAL double-axis control section designed for IndraDrive motion control systems. It provides control functionality for two digital drive axes and features PROFIBUS master communication, two encoder interfaces configured for IndraDyn, Hiperface, and 1 Vpp feedback systems, and an S1 safety technology I/O option. The two additional option positions are not equipped, and the unit has a standard control panel configuration. With its configurable architecture, the CDB01.1C supports industrial drive applications requiring coordinated motor control, encoder feedback, and integration with a higher-level automation system. Firmware is designated as a separate ordering subposition, so the required firmware version and availability should be checked before commissioning. This control section must be installed with the appropriate IndraDrive power section and associated system components.

2. Key Technical Specifications
- Brand: Bosch Rexroth
- Manufacturer / Alternate Brand: Rexroth Indramat
- Model: CDB01.1C
- Full Type Code: CDB01.1C-PB-ENS-ENS-NNN-NNN-S1-S-NN-FW
- Part Number: R911309015
- Product Series: IndraDrive CDB
- Product Type: BASIC UNIVERSAL Double-Axis Control Unit
- Axis Configuration: Two digital axes
- Master Communication: PROFIBUS
- Encoder Interface 1: ENS – IndraDyn / Hiperface / 1 Vpp
- Encoder Interface 2: ENS – IndraDyn / Hiperface / 1 Vpp
- Option 3 and Option 4: NNN – Not equipped
- Safety Technology: S1 – Safety technology I/O
- Control Panel: S – Standard control panel
- Other Design: NN – None
- Firmware: FW – Firmware ordered as a separate subposition
- Dimensions: Not officially confirmed for this exact configuration
- Weight: Not officially confirmed
- Country of Origin: Not independently verified
- Product Status: Legacy product; verify current manufacturer support and firmware availability
3. Application Scenarios
- Industrial motion control: Controls two digital drive axes in automated machinery.
- CNC and machine tools: Supports coordinated motor control and encoder feedback in configured IndraDrive installations.
- Packaging machinery: Used in synchronized motion applications involving multiple machine axes.
- Material handling: Supports controlled movement in automated conveying and positioning equipment.
- Production lines: Integrates drive control with higher-level automation through PROFIBUS.
- Mechanical processing equipment: Supports speed and position control where compatible motor and feedback configurations are installed.
- Legacy system maintenance: Provides an exact type-code spare option for existing IndraDrive CDB01.1C installations.
4. Installation and Operating Procedure
- Verify the complete type code and R911309015 part number against the installed drive documentation.
- Confirm the compatibility of the control section with the existing IndraDrive power section and motor configuration.
- Review the electrical drawings, PROFIBUS network configuration, encoder wiring, and safety circuit design.
- Shut down the drive system according to the machine manufacturer’s procedure.
- Isolate the power supply and observe the specified DC bus discharge time. Verify the absence of hazardous voltage before handling the equipment.
- Apply lockout/tagout procedures and record the original wiring and parameter configuration.
- Inspect the replacement control section, connectors, mounting surfaces, and identification labels.
- Install the module in the designated drive assembly according to the Bosch Rexroth installation instructions.
- Connect the PROFIBUS network and both encoder interfaces using the approved wiring and connector specifications.
- Verify the S1 safety technology I/O connections and associated safety circuit configuration.
- Load or verify the correct firmware and drive parameters using the approved Rexroth engineering tools.
- Perform controlled commissioning, encoder feedback checks, communication tests, and axis function tests before returning the machine to production.
5. Configuration and System Integration
The CDB01.1C is a configurable double-axis control section. Its complete type code identifies the communication interface, encoder options, expansion positions, safety technology, and control panel.
Configuration details for this unit:
- CDB01.1C: BASIC UNIVERSAL double-axis control section.
- PB: PROFIBUS master communication.
- ENS / ENS: Two encoder interfaces for IndraDyn, Hiperface, and 1 Vpp feedback systems.
- NNN / NNN: Both additional option positions are not equipped.
- S1: Safety technology I/O option.
- S: Standard control panel.
- NN: No additional design option.
- FW: Firmware is ordered as a separate subposition.
Integration considerations:
- Confirm that the PROFIBUS master configuration matches the host automation system.
- Verify encoder signal type, wiring, and motor feedback compatibility.
- Confirm that the connected motors and power sections are supported by the installed drive configuration.
- Check the firmware version and parameter set before replacing an existing controller.
- Verify the safety I/O configuration and the complete safety circuit before enabling motion.
- Do not assume that another CDB01.1C control section has identical functionality simply because its base model is the same.
6. Daily Maintenance and Inspection
- Inspect the control section for dust, contamination, corrosion, and physical damage.
- Check connectors and communication cables for secure connections.
- Review PROFIBUS diagnostics for communication errors or intermittent faults.
- Monitor encoder feedback signals and investigate abnormal position or speed readings.
- Check cabinet ventilation and ambient temperature against the equipment specifications.
- Inspect the drive assembly for signs of overheating or abnormal operating conditions.
- Maintain backups of drive parameters, firmware information, and commissioning records.
- Follow the maintenance intervals specified by the machine manufacturer and Bosch Rexroth documentation.
7. Troubleshooting Guide
Problem: PROFIBUS communication failure.
- Check the PROFIBUS cable, connectors, and network termination.
- Verify the node address and communication configuration.
- Inspect the host PLC diagnostics and drive communication status.
- Confirm that the installed firmware supports the configured communication setup.
Problem: Encoder feedback error.
- Verify the encoder type and ENS interface configuration.
- Inspect encoder cables, shielding, and connectors.
- Check the motor feedback device and signal quality.
- Compare the installed configuration with the approved motor and drive documentation.
Problem: Motor axis does not operate.
- Check the drive enable conditions and fault history.
- Verify the power section and motor connections.
- Review control parameters and axis configuration.
- Confirm that the safety circuit permits operation.
Problem: Safety technology I/O fault.
- Inspect the S1 safety I/O wiring and associated safety devices.
- Review safety diagnostics and the approved circuit design.
- Check the required safety signals and operating conditions.
- Have qualified personnel perform the required safety validation.
Problem: Controller replacement or firmware mismatch.
- Confirm the complete type code and hardware identification.
- Verify firmware availability and compatibility.
- Restore only an approved parameter backup.
- Complete the required commissioning and functional tests before releasing the machine.
8. Safety Precautions
- Installation and commissioning must be performed by qualified drive-system technicians.
- Isolate all relevant power sources before working on the drive.
- Observe the manufacturer’s DC bus discharge instructions and verify safe voltage conditions.
- Follow lockout/tagout procedures and the machine’s electrical safety requirements.
- Do not disconnect motor or encoder wiring while the system is energized.
- Do not bypass the S1 safety technology I/O or other machine protection functions.
- Verify the complete safety circuit after any control-section replacement or wiring modification.
- Do not enable motor movement until parameter, encoder, communication, and safety checks are complete.
- Use only approved firmware and configuration procedures.
9. Related Bosch Rexroth / Indramat Models
The following models and configurations belong to the IndraDrive control-section family or represent related drive-control options. They are useful for system identification and spare-part research, but they are not automatically interchangeable with R911309015.
- CDB01.1C-PB-ENS-ENS-NNN-NNN-L1-S-NN-FW – Double-axis BASIC UNIVERSAL configuration with starting lock-out.
- CDB01.1C-PB-ENS-ENS-NNN-NNN-NN-S-NN-FW – Double-axis BASIC UNIVERSAL configuration without the S1 safety option.
- CDB01.1C-PB-ENS-ENS-NNN-NNN-S2-S-NN-FW – Double-axis configuration with a different safety technology option.
- CDB01.1C-S3-EN1-EN1-NNN-NNN-NN-S-NN-FW – SERCOS III-related configuration with EN1 encoder options.
- CDB01.1C-S3-EN1-EN1-EN2-EN2-NN-S-NN-FW – Double-axis configuration with alternative encoder interfaces.
- CDB01.1C-S3-EN1-EN1-NNN-MA1-L1-S-NN-FW – Configuration with analog I/O expansion and starting lock-out.
- CDB01.1C-ET-EN2-EN2-NNN-NNN-NN-S-NN-FW – Multi-Ethernet communication configuration.
- CDB01.1C-PB-ENS-ENS-NNN-NNN-L2-S-NN-FW – PROFIBUS configuration with a different safety option.
- CDB01.1C-PB-ENS-ENS-NNN-NNN-NN-S-NN-FW – Related BASIC UNIVERSAL double-axis configuration.
- CDB01.1C – BASIC UNIVERSAL double-axis control-section family.
- CSB01.1C – BASIC single-axis control-section family.
- CSH01.1C – ADVANCED single-axis control-section family.
- CDB02 – IndraDrive BASIC UNIVERSAL double-axis control-section family.
- CSB02 – IndraDrive BASIC single-axis control-section family.
- CSH02 – IndraDrive ADVANCED single-axis control-section family.
Always compare the full ordering code, firmware, safety option, communication interface, and encoder configuration before selecting a replacement.
10. Product Verification and Purchasing Notes
Before purchasing, request photographs of the actual unit showing the front label, complete type code, R911309015 part number, connectors, and hardware identification. Confirm whether the item is new surplus, unused, refurbished, or previously installed. Ask whether the control section has been tested and whether a test report is available.
For replacement applications, verify the PROFIBUS interface, both ENS encoder options, S1 safety technology I/O, and firmware requirements. The control section must also match the installed IndraDrive power section and motor configuration.
The firmware designation FW indicates that firmware is ordered as a separate subposition. Confirm the firmware version and availability rather than assuming that the required firmware is included with the hardware.
This unit is intended for integration into a compatible IndraDrive system and should not be treated as a standalone drive or power supply.