The B&R Automation X20CP1484 is a central processing unit designed for the B&R X20 modular PLC system. It features an Intel Celeron 266-compatible processor with an additional I/O processor, onboard Ethernet, POWERLINK, RS232, two USB ports, and an X2X Link master interface. The controller supports CompactFlash application memory and provides one modular interface expansion slot for additional communication options. With fanless cooling and a compact design, the X20CP1484 is suitable for industrial machine control, distributed I/O management, and automation applications requiring deterministic communication. Its documented minimum task cycle time is 800 µs. Before installation or replacement, verify the hardware revision, SDRAM configuration, CompactFlash application, firmware, and Automation Studio project compatibility with the existing control system.

📋 Product Specifications
| Parameter | Description |
|---|---|
| Brand | B&R Automation |
| Model | X20CP1484 |
| Product Type | PLC CPU Module |
| Series | X20 System |
| Processor | Intel Celeron 266-compatible |
| I/O Processing | Integrated I/O processor |
| Standard Memory | 32 MB SDRAM |
| User RAM | 1 MB SRAM |
| Application Memory | CompactFlash slot |
| Communication Interfaces | RS232, Ethernet, POWERLINK, 2 × USB, X2X Link |
| Interface Expansion | 1 modular interface slot |
| Minimum Task Cycle Time | 800 µs |
| CPU Supply Voltage | 24 V DC, -15% / +20% |
| Maximum Input Current | 2.2 A |
| Power Consumption | 10.5 W, excluding memory card, interface module, and USB |
| Cooling | Fanless |
| Protection Rating | IP20 |
| Dimensions | 150 × 99 × 85 mm |
| Weight | Not confirmed; verify by physical measurement |
| Place of Manufacture | Not confirmed |
| Country of Origin | Verify product label or shipping documentation |
| Product Status | Legacy product; verify current availability |
| Discontinued | Current lifecycle status not confirmed |
| Application | Industrial PLC control and X20 system management |
⚙️ Installation and Operation
- Installation: Disconnect the control cabinet power supply. Mount the CPU in the designated X20 system arrangement and check the bus connection, terminal block, grounding, and interface-slot configuration. Confirm that the installed CompactFlash card is suitable for the application.
- Power-On: Apply the specified 24 V DC supply within the manufacturer’s permitted voltage range. Check the CPU, Ethernet, POWERLINK, CompactFlash, battery, and overtemperature indicators.
- Normal Operation: Monitor CPU status, communication activity, I/O data exchange, and controller diagnostics through the approved B&R engineering environment. Confirm that connected X20 modules and network devices are recognized.
- Parameter and Configuration Changes: Use the appropriate B&R Automation Studio version and compatible hardware configuration. Back up the existing application and configuration before changing communication settings, I/O assignments, firmware, or retained data.
- Power-Off: Stop the controlled machine using the approved shutdown procedure, place outputs in a safe state, and isolate the power supply before removing the CPU or changing wiring and modules.
🔧 Maintenance and Troubleshooting
- CPU does not start: Check the 24 V DC supply, terminal connections, system bus seating, and status indicators.
- CompactFlash or application error: Inspect the memory card, application files, and project compatibility. Use a verified backup when restoring the application.
- Ethernet or POWERLINK communication fault: Check cable condition, connector seating, network configuration, node settings, and connected device status.
- Battery warning: Check the battery diagnostic status and follow the OEM replacement procedure. Protect retained data before replacement.
- Overtemperature indication: Inspect cabinet ventilation, ambient temperature, mounting clearance, and nearby heat sources.
- Intermittent I/O communication: Inspect X2X Link connections, module seating, supply stability, and system diagnostics.
🛡️ Safety Precautions
- Installation and servicing should be performed by qualified industrial automation personnel.
- Isolate power before wiring, removing, or replacing the CPU.
- Confirm polarity, supply voltage, protective grounding, and terminal assignments against the official hardware documentation.
- Do not insert or remove CompactFlash media or interface modules while energized unless the OEM procedure explicitly permits it.
- Do not assume that another X20 CPU model has identical memory, firmware, or interface configuration.
- Verify the complete control-system response and safety functions before returning equipment to service.
🔗 Related B&R Models
The following are related B&R X20 CPU and system modules for reference. They are not automatically interchangeable with the X20CP1484; verify hardware, firmware, memory, and application compatibility before selecting a replacement.
- B&R X20CP1483
- B&R X20CP1483-1
- B&R X20CP1484-1
- B&R X20CP1485
- B&R X20CP1485-1
- B&R X20CP1486
- B&R X20CP3484
- B&R X20CP3484-1
- B&R X20CP3485
- B&R X20CP3485-1
- B&R X20CP3486
- B&R X20CP0482
- B&R X20CP0483
- B&R X20CP0484
- B&R X20CP3584